Amaç: Bu
çalışmanın amacı, bilgisayar yardımlı tasarım/bilgisayar yardımlı imalat
(BYT/BYİ; CAD/CAM) anterior diş endo-kron ve fiberle güçlendirilmiş kompozit
(FGK) esaslı post-kor restorasyonunun kırılma yükünün değerlendirilmesidir.
Gereç ve
Yöntem: CAD/CAM ile kanin kök modeli şeklinde zirkonya model (Ice
Zirconia, ZirkonZahn GmBH, Bruneck, Italy) üzerinde toplam 40 post-kor destekli
kron ve endokron yapıldı. Statik taşıma yükü kapasitesi değerlendirmesi şu
restorasyon gruplarında yapıldı: Grup 1: CAD/CAM tek parça FGK post-kor-kron
sistemi (deneysel CAD/CAM FGK blok) ile desteklenen zirkonya kron (Prettau
anterior, ZirkonZahn GmBH); Grup 2: Devamlı olmayan FGK kor (EverX posterior,
GC Corp., Tokyo, Japan) ve FGK post (GC Corp.) ile desteklenen zirkonya kron
(Prettau anterior); Grup 3: Zirkonya endokron (Prettau anterior) ve Grup 4:
Lityum disilikat seramik endokron (IPS e.max CAD, Ivoclar Vivadent AG, Schaan,
Liechtenstein) (n = 10/grup). Kronların/endokronların zirkonya kök modele
adeziv simantasyonunu takiben, universal test cihazında dişlerin uzun eksenine
45° olacak şekilde yük uygulandı. Kırık modları görsel olarak değerlendirildi.
İstatistiksel analiz tek-yönlü ANOVA ve Tukey post-hoc testleri ile
gerçekleştirildi.
Bulgular: Grupların
kırılma yükü değerleri arasında anlamlı farklılık gözlendi (p<0.05). Grupların
istatistiksel olarak sıralanması şu şekildedir: Grup 3 (1168 ± 141 N) > Grup
4 (721 ± 96 N) ≥ Grup 1 (680 ± 86 N) > Grup 2 (534 ± 36 N).
Sonuç: Endokron
monoblok restorasyonlar, fiberle güçlendirilmiş post-kor restorasyon destekli
kron restorasyonlara alternatif olarak kullanılabilir.
Bilgisayar yardımlı tasarım bilgisayar yardımlı imalat kök çivisi tekniği seramikler
Objective: This study aimed to evaluate the fracture load
of endocrown restorations and fiber-reinforced composites (FRCs) fabricated
through computer-aided design/computer-aided manufacturing (CAD-CAM) for
post–cores of anterior teeth.
Materials and Method: Forty post–core-supported crowns and endocrowns
were fabricated through CAD-CAM on a canine root zirconia model (Ice Zirconia,
ZirkonZahn GmBH, Bruneck, Italy). The static load-bearing
capacity was measured on the following restoration groups: Group 1: zirconia
crown (Prettau anterior, ZirkonZahn GmBH) retained with CAD-CAM one-piece FRC post-core
crown system (experimental CAD-CAM FRC block); Group 2: zirconia crown (Prettau
anterior) retained with FRC post (GC Corp., Tokyo, Japan) with discontinuous
fiber composite (EverX posterior, GC Corp) core; Group 3: zirconia endocrown
(Prettau anterior); and Group 4: lithium disilicate ceramic endocrown (IPS
e.max CAD, Ivoclar Vivadent AG, Schaan, Liechtenstein) (n = 10/per group).
After the adhesive cementation of crowns/endocrowns to the zirconia root model,
a load was applied at 45° to the long axis of the teeth and measured using a
universal testing machine. The fracture modes were visually examined. The statistical
analyses were performed using one-way ANOVA and Tukey post-hoc tests (p <
0.05).
Results: The fracture
load significantly differed among the groups (p < 0.05) and was ranked as
follows: Group 3 (1168 ± 141 N) > Group 4 (721 ± 96 N) ≥ Group 1 (680 ± 86
N) > Group 2 (534 ± 36 N).
Conclusion: Endocrown monoblock restorations can be used as
an alternative to fiber-reinforced post–core supported crown restorations.
Ceramics Computer-aided manufacturing Post and core technique Computer-aided design Post and core technique
Konular | Sağlık Kurumları Yönetimi |
---|---|
Bölüm | Özgün Araştırma Makalesi |
Yazarlar | |
Yayımlanma Tarihi | 12 Nisan 2018 |
Yayımlandığı Sayı | Yıl 2018 |