Araştırma Makalesi
BibTex RIS Kaynak Göster

Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files

Yıl 2023, Cilt: 40 Sayı: 3, 79 - 83, 04.09.2023
https://doi.org/10.17214/gaziaot.1143423

Öz

OBJECTIVE: The aim of this study was to compare the effect of nickel-titanium file systems with different taper angles working with rotation and reciprocation motion on the amount of debris extruding apically.
MATERIALS AND METHOD: The study was performed using the Myers and Montgomery model. Forty-five human maxillary anterior teeth were inserted into preweighed Eppendorf tubes and randomly classified into three groups. After manual glide-path preparation, the teeth in each group were instrumented to the working length set 1 mm short of the anatomical apex using the standard sequence provided by the manufacturers: Group 1: Reciproc Blue (Easy In Smile, New Jersey, USA), Group 2: T-endo must (Dentac, İstanbul, Turkey),Group 3: T-endo mis (Dentac, İstanbul, Turkey). Root canals were irrigated with 10 mL 2.5% NaOCl, 17% EDTA, and distilled water between each file insertion. The tubes with collected debris were stored in an incubator at 70°C for 7 days. Measurement of the weight of extruded debris was performed by subtracting the pre-instrumentation from the post-instrumentation weight of the tubes. Data were analyzed using one-way ANOVA and Tukey’s Honest Significant Difference Test (α=0.05).
RESULTS: The weights of the apically extruded debris were 0.0094±0.0015 g in Group 1, 0.0075±0.0012 g in Group 2, and 0.0044±0.0010 g in Group 3, and the difference between all groups was statistically significant (p<0.05).
CONCLUSION: The amount of apically extruded debris is related to the taper angle of the file used and the kinematics of the file.

Kaynakça

  • Chércoles-Ruiz A, Sanchez-Torres A, Gay-Escoda C. Endodontics, endodontic retreatment, and apical surgery versus tooth extraction and implant placement: A systematic review. J Endod 2017;43:679-86.
  • Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559-67.
  • Seltzer S, Naidorf IJ. Flare-ups in endodontics: I. Etiological factors. J Endod 1985;11:472–8.
  • Siqueira JF. Microbial causes of endodontic flare-ups. Int Endod J 2003;36:453–63.
  • Ustun Y, Canakci BC, Dincer AN, Er O, Duzgun S. Evaluation of apically extruded debris associated with several Ni-Ti systems. Int Endod J 2015;48:701-4.
  • Nayak G, Singh I, Shetty S, Dahiya S. Evaluation of apical extrusion of debris and irrigant using two new reciprocating and one continuous rotation single file systems. J Dent Tehran 2014;11:302-9.
  • Uzun I, Guler B, Ozyurek T, Tunc T. Apical extrusion of debris using reciprocating files and rotary instrumentation systems. Niger J Clin Pract 2016;19:71-5.
  • Gündoğar M, ÖzyürekT. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue nickel-titanium instruments. J Endod 2017;43:1192–6.
  • Boijink D, Costa DD, Hoppe CB, Kopper PMP, Grecca FS. Apically Extruded Debris in Curved Root Canals Using the WaveOne Gold Reciprocating and Twisted File Adaptive Systems. J Endod 2018;44:1289-92.
  • T-endo Must Brochure [Internet]. [cited 2022 July 12]. Available from: https://dentac.com/img/D/must-eng.pdf
  • De-Deus G, Silva EJ, Vieira VT, Belladonna FG, Elias CN, Plotino G. et al. Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc Files. J Endod 2017;43:462-6.
  • T-endo Mis Brochure[Internet].[cited 2022 July 12]. Available from: https://dentac.com/img/K/katalog.pdf
  • Myers GL, Montgomery S. A comparison of weights of debris extruded apically by conventional filing and Canal Master techniques. J Endod 1991;17:275-9.
  • Ruiz-Hubard EE, Gutmann JL, Wagner MJ. A quantitative assessment of canal debrisforced periapically during root canal instrumentation using two different techniques.J Endod 1987;13:554–8.
  • Reddy SA, Hicks ML. Apical extrusion of debris using two hand and two rotary instrumentation techniques. J Endod 1998;24:180-3.
  • Beeson TJ, Hartwell GR, Thornton JD, Gunsolley JC. Comparison of debris extruded apically in straight canals: conventional filing versus profile .04 Taper series 29. J Endod 1998;24:18-22.
  • Uslu G, Özyürek T, Yılmaz K, Gündoğar M, Plotino G. Apically Extruded Debris during Root Canal Instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper Nickel-titanium Files. J Endod 2018;44:856-9.
  • Inan U, Keskin C, Sivas Yilmaz Ö. Cyclic fatigue of reciproc blue and reciproc instruments exposed to intracanal temperature in simulated severe apical curvature. Clin Oral Investig 2019;23:2077-82.
  • Romeiro K, de Almeida A, Cassimiro M, Gominho L, Dantas E, Chagas N, et al. Reciproc and Reciproc Blue in the Removal of Bioceramic and Resin-Based Sealers in Retreatment Procedures. Clin Oral Investig 2020;24:405-16.
  • Marinho E, Arslan H. The effect of blue thermal treatment on endodontic instruments and apical debris extrusion during retreatment procedures. Int Endod J 2019;52:1629-34.
  • Çanakçi BC, Ustun Y, Er O, Genc Sen O, Sen OG. Evaluation of apically extruded debris from curved root canal filling removal using 5 nickel-titanium systems. J Endod 2016;42:1101-04.
  • Djuric NP, Vyver PVD, Vorster M, Vally ZI. Comparison of apical debris extrusion using clockwise and counter-clockwise single-file reciprocation of rotary and reciprocating systems. Aust Endod J 2021;47:394-400.
  • Caviedes-Bucheli J, Castellanos F, Vasquez N, Ulate E, Munoz HR. The influence of two reciprocating single-file and two rotary-file systems on the apical extrusion of debris and its biological relationship with symptomatic apical periodontitis. A systematic review and metaanalysis. Int Endod J 2016;49:255-70.
  • Tinoco JM, De-Deus G, Tinoco EM, Saavedra F, Fidel RAS, Sassone LM. Apical extrusion of bacteria when using reciprocating single-file and rotary multifile instrumentation systems. Int Endod J 2014;47:560-6.
  • Arslan H, Doğanay E, Alsancak M, Çapar ID, Karataş E, Gündüz HA. Comparison of apically extruded debris after root canal instrumentation using Reciproc instruments with various kinematics. Int Endod J 2016;49:307-10.
  • Burklein S, Schafer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod 2012;38:850-2.
  • Toyoglu M, Altunbas¸ D. Influence of different kinematics on apical extrusion of irrigantand debris during canal preparation using K3XF instruments. J Endod 2017;43:1565-8.
  • Ahmad MZ, Sadaf D, MacBain MM, Merdad KA. Effect of mode of rotation on apical extrusion of debris with four different single-file endodontic instrumentation systems: Systematic review and meta-analysis. Aust Endod J 2022;48:202-18.
  • Sinha S, Singh K, Singh A, Priya S, Kumar A, Kawle S. Quantitative Evaluation of Apically Extruded Debris in Root Canals prepared by Single-file Reciprocating and Single File Rotary Instrumentation Systems: A Comparative In vitro Study. J Pharm Bioallied Sci 2021;13:1398-401.
  • Eliasz W, Czarnecka B, Surdacka A. Apical Extrusion of Debris during Root Canal Preparation with ProTaperNext,WaveOne Gold and Twisted Files. Materials (Basel) 2021;14:6254.
  • Onalan AC, Oztekin F. Comparison of the Amount of Debris Extruding from the Apical in Teeth Using Nickel Titanium File Systems with Different Taper Angles with Rotation Movement. HRU Int J Dent Oral Res 2022;2:34-40.
  • Lambrianidis T, Tosounidou E, Tzoanopoulou M. The effect of maintaining apical patency on periapical extrusion. J Endod 2001;27:696-8.
  • Abou-Rass M, Piccinino MV. The effectiveness of four clinical irrigation methods on the removal of root canal debris. Oral Surg Oral Med Oral Pathol 1982;54:323-8.
  • Salzgeber RM, Brilliant JD. An in vivo evaluation of the penetration of an irrigating solution in root canals. J Endod 1977;3:394-8.
  • Altundasar E, Nagas E, Uyanık O, Serper A. Debris and irrigant extrusion potential of 2 rotary systems and irrigation needles. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;112:31-5.
  • Lu Y, Wang R, Zhang L, LiH L, ZhengQ H, ZhouX D et al. Apically extruded debris and irrigant with two Ni-Ti systems and hand files when removing root fillings: a laboratory study. Int Endod J 2013;46:1125-30.

T-endo must, T-endo mis ve Reciproc Blue Kanal Eğeleri ile Kanal Şekillendirmesi Sırasında Apikalden Taşan Debris Miktarının Karşılaştırılması

Yıl 2023, Cilt: 40 Sayı: 3, 79 - 83, 04.09.2023
https://doi.org/10.17214/gaziaot.1143423

Öz

Amaç: Bu çalışmanın amacı, rotasyon ve resiprokasyon hareketi ile çalışan farklı koniklik açılarına sahip nikel titanium eğe sistemlerinin apikalden taşan debris miktarına etkisini karşılaştırmaktır.
Gereç ve Yöntem: Çalışma Myers ve Montgomery modeli kullanılarak yapıldı. Kırk beş insan üst kesici diş önceden tartılmış Eppendorf tüplerine yerleştirildi ve anatomik apeksten 1 mm kısa çalışma boyu olacak şekilde Grup 1: Reciproc Blue (Easy In Smile, New Jersey, ABD); Grup 2: T-endo must (Dentac, İstanbul, Türkiye), Grup 3: T-endo mis (Dentac, İstanbul, Türkiye) ile şekillendirildi. Kök kanalları 10 mL %2.5 NaOCl, %17 EDTA ve distile su ile irrige edildi. İçerisinde debris olan tüpler 7 gün boyunca 70 °C inkübatörde bekletildi. Tüplerin son ağırlığından ilk ağırlıkları çıkarılarak apikalden taşan debris miktarları elde edildi. Veriler, tek yönlü ANOVA ve Tukey çoklu karşılaştırma testi ile değerlendirildi (α=0,05).
Bulgular: Grup 1'de 0.0094±0.0015 g, Grup 2'de 0.007±0.0012 g ve Grup 3'te 0.0044±0.0010 g debris görüldü. Tüm gruplar arasındaki fark istatistiksel olarak anlamlı bulundu (p<0.05).
Sonuç: Apikalden taşan debris miktarı, kullanılan eğenin koniklik açısı ve eğenin kinematiği ile ilgilidir.

Kaynakça

  • Chércoles-Ruiz A, Sanchez-Torres A, Gay-Escoda C. Endodontics, endodontic retreatment, and apical surgery versus tooth extraction and implant placement: A systematic review. J Endod 2017;43:679-86.
  • Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559-67.
  • Seltzer S, Naidorf IJ. Flare-ups in endodontics: I. Etiological factors. J Endod 1985;11:472–8.
  • Siqueira JF. Microbial causes of endodontic flare-ups. Int Endod J 2003;36:453–63.
  • Ustun Y, Canakci BC, Dincer AN, Er O, Duzgun S. Evaluation of apically extruded debris associated with several Ni-Ti systems. Int Endod J 2015;48:701-4.
  • Nayak G, Singh I, Shetty S, Dahiya S. Evaluation of apical extrusion of debris and irrigant using two new reciprocating and one continuous rotation single file systems. J Dent Tehran 2014;11:302-9.
  • Uzun I, Guler B, Ozyurek T, Tunc T. Apical extrusion of debris using reciprocating files and rotary instrumentation systems. Niger J Clin Pract 2016;19:71-5.
  • Gündoğar M, ÖzyürekT. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue nickel-titanium instruments. J Endod 2017;43:1192–6.
  • Boijink D, Costa DD, Hoppe CB, Kopper PMP, Grecca FS. Apically Extruded Debris in Curved Root Canals Using the WaveOne Gold Reciprocating and Twisted File Adaptive Systems. J Endod 2018;44:1289-92.
  • T-endo Must Brochure [Internet]. [cited 2022 July 12]. Available from: https://dentac.com/img/D/must-eng.pdf
  • De-Deus G, Silva EJ, Vieira VT, Belladonna FG, Elias CN, Plotino G. et al. Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc Files. J Endod 2017;43:462-6.
  • T-endo Mis Brochure[Internet].[cited 2022 July 12]. Available from: https://dentac.com/img/K/katalog.pdf
  • Myers GL, Montgomery S. A comparison of weights of debris extruded apically by conventional filing and Canal Master techniques. J Endod 1991;17:275-9.
  • Ruiz-Hubard EE, Gutmann JL, Wagner MJ. A quantitative assessment of canal debrisforced periapically during root canal instrumentation using two different techniques.J Endod 1987;13:554–8.
  • Reddy SA, Hicks ML. Apical extrusion of debris using two hand and two rotary instrumentation techniques. J Endod 1998;24:180-3.
  • Beeson TJ, Hartwell GR, Thornton JD, Gunsolley JC. Comparison of debris extruded apically in straight canals: conventional filing versus profile .04 Taper series 29. J Endod 1998;24:18-22.
  • Uslu G, Özyürek T, Yılmaz K, Gündoğar M, Plotino G. Apically Extruded Debris during Root Canal Instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper Nickel-titanium Files. J Endod 2018;44:856-9.
  • Inan U, Keskin C, Sivas Yilmaz Ö. Cyclic fatigue of reciproc blue and reciproc instruments exposed to intracanal temperature in simulated severe apical curvature. Clin Oral Investig 2019;23:2077-82.
  • Romeiro K, de Almeida A, Cassimiro M, Gominho L, Dantas E, Chagas N, et al. Reciproc and Reciproc Blue in the Removal of Bioceramic and Resin-Based Sealers in Retreatment Procedures. Clin Oral Investig 2020;24:405-16.
  • Marinho E, Arslan H. The effect of blue thermal treatment on endodontic instruments and apical debris extrusion during retreatment procedures. Int Endod J 2019;52:1629-34.
  • Çanakçi BC, Ustun Y, Er O, Genc Sen O, Sen OG. Evaluation of apically extruded debris from curved root canal filling removal using 5 nickel-titanium systems. J Endod 2016;42:1101-04.
  • Djuric NP, Vyver PVD, Vorster M, Vally ZI. Comparison of apical debris extrusion using clockwise and counter-clockwise single-file reciprocation of rotary and reciprocating systems. Aust Endod J 2021;47:394-400.
  • Caviedes-Bucheli J, Castellanos F, Vasquez N, Ulate E, Munoz HR. The influence of two reciprocating single-file and two rotary-file systems on the apical extrusion of debris and its biological relationship with symptomatic apical periodontitis. A systematic review and metaanalysis. Int Endod J 2016;49:255-70.
  • Tinoco JM, De-Deus G, Tinoco EM, Saavedra F, Fidel RAS, Sassone LM. Apical extrusion of bacteria when using reciprocating single-file and rotary multifile instrumentation systems. Int Endod J 2014;47:560-6.
  • Arslan H, Doğanay E, Alsancak M, Çapar ID, Karataş E, Gündüz HA. Comparison of apically extruded debris after root canal instrumentation using Reciproc instruments with various kinematics. Int Endod J 2016;49:307-10.
  • Burklein S, Schafer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod 2012;38:850-2.
  • Toyoglu M, Altunbas¸ D. Influence of different kinematics on apical extrusion of irrigantand debris during canal preparation using K3XF instruments. J Endod 2017;43:1565-8.
  • Ahmad MZ, Sadaf D, MacBain MM, Merdad KA. Effect of mode of rotation on apical extrusion of debris with four different single-file endodontic instrumentation systems: Systematic review and meta-analysis. Aust Endod J 2022;48:202-18.
  • Sinha S, Singh K, Singh A, Priya S, Kumar A, Kawle S. Quantitative Evaluation of Apically Extruded Debris in Root Canals prepared by Single-file Reciprocating and Single File Rotary Instrumentation Systems: A Comparative In vitro Study. J Pharm Bioallied Sci 2021;13:1398-401.
  • Eliasz W, Czarnecka B, Surdacka A. Apical Extrusion of Debris during Root Canal Preparation with ProTaperNext,WaveOne Gold and Twisted Files. Materials (Basel) 2021;14:6254.
  • Onalan AC, Oztekin F. Comparison of the Amount of Debris Extruding from the Apical in Teeth Using Nickel Titanium File Systems with Different Taper Angles with Rotation Movement. HRU Int J Dent Oral Res 2022;2:34-40.
  • Lambrianidis T, Tosounidou E, Tzoanopoulou M. The effect of maintaining apical patency on periapical extrusion. J Endod 2001;27:696-8.
  • Abou-Rass M, Piccinino MV. The effectiveness of four clinical irrigation methods on the removal of root canal debris. Oral Surg Oral Med Oral Pathol 1982;54:323-8.
  • Salzgeber RM, Brilliant JD. An in vivo evaluation of the penetration of an irrigating solution in root canals. J Endod 1977;3:394-8.
  • Altundasar E, Nagas E, Uyanık O, Serper A. Debris and irrigant extrusion potential of 2 rotary systems and irrigation needles. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;112:31-5.
  • Lu Y, Wang R, Zhang L, LiH L, ZhengQ H, ZhouX D et al. Apically extruded debris and irrigant with two Ni-Ti systems and hand files when removing root fillings: a laboratory study. Int Endod J 2013;46:1125-30.
Toplam 36 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Diş Hekimliği, Endodonti
Bölüm Özgün Araştırma Makalesi
Yazarlar

Funda Fundaoğlu Küçükekenci 0000-0002-9619-545X

Yayımlanma Tarihi 4 Eylül 2023
Yayımlandığı Sayı Yıl 2023 Cilt: 40 Sayı: 3

Kaynak Göster

APA Fundaoğlu Küçükekenci, F. (2023). Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files. Acta Odontologica Turcica, 40(3), 79-83. https://doi.org/10.17214/gaziaot.1143423
AMA Fundaoğlu Küçükekenci F. Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files. Acta Odontol Turc. Eylül 2023;40(3):79-83. doi:10.17214/gaziaot.1143423
Chicago Fundaoğlu Küçükekenci, Funda. “Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-Endo Must, T-Endo Mis, and Reciproc Blue Files”. Acta Odontologica Turcica 40, sy. 3 (Eylül 2023): 79-83. https://doi.org/10.17214/gaziaot.1143423.
EndNote Fundaoğlu Küçükekenci F (01 Eylül 2023) Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files. Acta Odontologica Turcica 40 3 79–83.
IEEE F. Fundaoğlu Küçükekenci, “Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files”, Acta Odontol Turc, c. 40, sy. 3, ss. 79–83, 2023, doi: 10.17214/gaziaot.1143423.
ISNAD Fundaoğlu Küçükekenci, Funda. “Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-Endo Must, T-Endo Mis, and Reciproc Blue Files”. Acta Odontologica Turcica 40/3 (Eylül 2023), 79-83. https://doi.org/10.17214/gaziaot.1143423.
JAMA Fundaoğlu Küçükekenci F. Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files. Acta Odontol Turc. 2023;40:79–83.
MLA Fundaoğlu Küçükekenci, Funda. “Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-Endo Must, T-Endo Mis, and Reciproc Blue Files”. Acta Odontologica Turcica, c. 40, sy. 3, 2023, ss. 79-83, doi:10.17214/gaziaot.1143423.
Vancouver Fundaoğlu Küçükekenci F. Comparison of Apically Extruded Debris During Root Canal Instrumentation Using T-endo must, T-endo mis, and Reciproc Blue Files. Acta Odontol Turc. 2023;40(3):79-83.