Aim: The aim of the present study is to determine the effects of ultraspeed, extraspeed, insight film and CCD sensor systems on buccal caries detection. In our study 15 teeth with buccal caries were positive gold standard group and 15 intact teeth were negative controls
Material-Method: Several studies were made regarding different emulsions. Literature survey revealed that there were not any statistically significant differences between diagnostic qualities of various film emulsions. In 1987, direct digital radiography (DDR) was
introduced as an alternative to conventional radiographic technique. Since x-ray sensitive sensors are utilized, this technique requires
less radiation and images can be obtained instantly without chemical processing. By use of ultraspeed, extraspeed, insight films and
RVG sensor radiographic images were obtained with bite-wing technique. Images were evaluated by 2 observers and ROC diagram
curves were drawn.
Results: Statistically, only for the second observer significant difference were found between extraspeed and insight radiographs
(p<0.05). In addition, there was not any statistically significant difference for the whole radiographic sets and between two observers
(p>0.05).
Buccal caries ultraspeed film ektaspeed film insight film direct digital radiography
Amaç: Bu çal›flman›n amac›, Ultraspeed, Ektaspeed ve Insight filemlerin ve CCD sensör sisteminin bukkal çürüklerin görünebilirli-
¤i üzerindeki etkilerinin ortaya konmas›d›r.
Gereç - Yöntem: Farkl› emülsiyonlarla ilgili olarak birçok çal›flma yap›lm›flt›r. Literatürler incelendi¤inde, film emülsiyonlar›n›n diagnostik kalitelerinin aras›nda ço¤u kez istatistiksel aç›dan anlaml› bir fark olmad›¤› ortaya konmufltur. 1987’ de konvansiyonel radyografik tekni¤e alternatif olarak direkt dijital radyografik (DDR) teknik gelifltirilmifltir. Bu teknikte x-›fl›nlar›na hassas olan sensörler kullan›ld›¤› için konvansiyonel tekni¤e oranla çok daha az radyasyon dozu ile ve banyo ifllemi olmaks›z›n k›sa bir sürede görüntü elde edilmektedir. Araflt›rmam›zda kullan›lan 15 adet bukkal çürüklü difl pozitif gold standart olarak al›nm›fl 15 adet sa¤lam diflte
negatif olarak de¤erlendirilmifltir. Bite-wing tekni¤i ile Ultraspeed, ektaspeed, Insight ve RVG sensörü ›fl›nlanarak elde edilen görüntülere 2 gözlemcinin verdi¤i de¤erler saptanm›fl ve eflik de¤erler ROC diagram› ile çizilmifltir.
Bulgular: ‹statistiksel olarak yaln›z 2. gözlemci için Ektaspeed radyograflar ile Insight grubu radyograflar aras›nda belirgin farkl›l›k
bulunmufltur (p<0,05). Bunun d›fl›nda her iki gözlemci aras›nda ve bütün radyograf setleri için istatistiksel olarak anlaml› bir farkl›-
l›k bulunmam›flt›r (p>0,05).
Sonuç: Bukkal çürüklerin görünebilirli¤i aç›s›ndan herhangi bir radyografik teknik veya görüntü sisteminin birbirine üstünlü¤ü bulunamam›flt›r
Bukkal karies ultraspeed film ektaspeed film insight film direkt dijital radyografi