In this article, rotor swing stabilizer system has been analyzed according to fault tolerant control FTC methodology. Fault tolerant control is presented in a general framework and Failure Mode and Effects Analysis FMEA is applied as a fault analysis method. The focus was on the category of requirements, process and components to find risky elements and provide solutions. The general methodology covered the failure mode and effect analysis and implementation of fault tolerant control systems on an overall level but still have a potential for improving immunity to component faults
Magnus effect Failure mode and effect analysis Fault tolerant control Stabilizer system
Birincil Dil | İngilizce |
---|---|
Bölüm | Araştırma Makaleleri |
Yazarlar | |
Yayımlanma Tarihi | 1 Aralık 2016 |
Yayımlandığı Sayı | Yıl 2016 Sayı: 07 |
Bu site ve içerisinde yayınlanan eserler Creative Commons AI 4.0 Uluslararası Lisansı ile lisanslanmıştır.
GiDB|DERGi, İstanbul Teknik Üniversitesi tarafından yayınlanmaktadır.