EN
TR
Determination of the indoor air quality and occupancy satisfaction in architecture studios during model making process
Abstract
In this study, measurements were performed to determine the indoor air quality and thermal comfort, evaluated to ASHRAE standard during the model making process of the students in the studios where architectural education was given, and whether the low indoor air quality obtained had an effect on the health of the students was determined by the survey method. As a result of the measurements, it was determined that the size of the studio space was largely effective in maintaining the indoor air quality for a long time, and although the natural ventilation continued uninterrupted during the model making, the indoor quality in the studios reached the values that would threaten the health of the students. In addition, it was determined that female students were more disturbed by the low indoor quality than male students.
Keywords
Destekleyen Kurum
Karabük Üniversitesi
Proje Numarası
FDT 2020-2218
Kaynakça
- Annesi-Maesano, I., Baiz, N., Banerjee, S., Rudnai, P., Rive, S., Sinphonie Group (2013). Indoor air quality and sources in schools and related health effects. Journal of Toxicology and Environmental Health, Part B 16(8), 491-550. DOI: 10.1080/10937404.2013.853609
- ASHRAE, 55 (2017). Thermal Environmental Conditions for Human Occupancy, in Atlanta, Georgia: American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. http://arco-hvac.ir/wpcontent/uploads/2015/11/ASHRAE_Thermal_Comfort_Standard.pdf
- Bakó-Biró, Z., Clements-Croome, D.J., Kochhar, N., Awbi, H.B., Williams, M.J. (2012) Ventilation rates in schools and pupils’ performance. Building and Environment, 48, 215-223. DOI: 10.1016/j.buildenv.2011.08.018
- Bogdanovica, S., Zemitis, J., Bogdanovics, R. (2020). The effect of CO2 concentration on children’s well-being during the process of learning. Energies, 13(22), 6099. DOI: 10.3390/en13226099
- Bostancı Başkan, T., Sözen Şerefhanoğlu, M. (2006). Dersliklerde görsel konfor ve etkin enerji kullanımı-bir örnek derslik aydınlatması. (Turkish) “Visual Comfort and Efficient Energy Use in Classrooms Lighting – A Field Study of Classrooms Lighting” Megaron, 1.2(3), 143-153. https://app.trdizin.gov.tr/dokumangoruntule?ext=pdf&path=CrnWZGRsXTjRjLjWxD978OSUAL2jXitizhVYmCxNvH55i17y72f60ZdhXjBfHwGff91V2nVIO9jllq5Memy8R3RGJC63zqAxfVCzSBtW2agDunfm5aaAY1p6m0CVVlWiF7B8ZZMVtrNgA78MadUDugISy7hYTgyfPbe5DZ5MUD9l7n2uogm3ZhccaBI33TlznZ1VO
- Destaillats, H., Maddalena, R.L., Singer, B.C., Hodgson, A.T., McKone, T.E. (2008). Indoor pollutants emitted by office equipment: A review of reported data and information needs. Atmospheric Environment, 42(7), 1371-1388. DOI: 10.1016/j.atmosenv.2007.10.080
- Djabarouti, J, O’Flaherty, C. (2019) Experiential learning with building craft in the architectural design studio: A pilot study exploring its implications for built heritage in the UK. Thinking Skills and Creativity, 32, 102-113. DOI: 10.1016/j.tsc.2019.05.003
- Düzenli, T., Yilmaz, S., Alpak, E. M. (2017). The effects of model making on design and learning in landscape architecture education. Eurasian Journal of Educational Research, 17(70), 121-134. DOI: 10.14689/EJER.2017.70.7
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mimarlık
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
30 Ocak 2023
Gönderilme Tarihi
1 Aralık 2021
Kabul Tarihi
12 Ocak 2023
Yayımlandığı Sayı
Yıl 2023 Cilt: 6 Sayı: 1
APA
Tuna Kayılı, M., & Yetiş, C. (2023). Determination of the indoor air quality and occupancy satisfaction in architecture studios during model making process. GRID - Architecture Planning and Design Journal, 6(1), 30-55. https://doi.org/10.37246/grid.1031184
Cited By
Investigation of indoor air quality in painting studios and health risk assessment
International Journal of Environmental Studies
https://doi.org/10.1080/00207233.2024.2379115