Araştırma Makalesi

Experimental Investigation of the Effects of Insulation Materials and Concrete Strength on Temperature Transitions in FRP Reinforced Structural Elements Under High Temperature

Cilt: 11 Sayı: 1 25 Mart 2023
PDF İndir
EN TR

Experimental Investigation of the Effects of Insulation Materials and Concrete Strength on Temperature Transitions in FRP Reinforced Structural Elements Under High Temperature

Öz

There are serious concerns about the preference of Fiber Reinforced Polymer (FRP) bars, which are widely used in buildings, in reinforced concrete structures due to their sensitivity to high temperatures. Especially in cases where the glass transition temperature of FRPs exceeds, losses occur in the mechanical and physical properties of FRP bars. Fire insulation materials used in reinforced concrete structures are of great importance in protecting the building elements against high temperatures. Insulation materials protect concrete and rebars against high temperatures and prevent strength reductions. In this study, the effects of different fire insulation materials and concrete strength on temperature transitions in FRP reinforced concrete structural elements were determined by experimental studies. The protection performances of the concrete and the rebars in the concrete against the effects of temperature were investigated. The study was carried out in 500 oC environments that can reach the glass transition temperature (80-110 oC) of FRP bars. Ambient temperatures, concrete surface temperatures and reinforcement surface temperatures in the concrete were measured depending on time with the experimental setup created. As a result of the study, it was determined that fire insulation materials are more effective than concrete strengths. In the effect of ambient temperature on the concrete surface, while the rock wool allowed a temperature transition of 13%, this value was 22% in glass wool and 26% in red drywall.

Anahtar Kelimeler

Kaynakça

  1. [1] A. Bahrami and M. Nematzadeh, “Bond behavior of lightweight concrete-filled steel tubes containing rock wool waste after exposure to high temperatures,” Constr. Build. Mater., vol. 300, p. 124039, Sep. 2021, doi: 10.1016/J.CONBUILDMAT.2021.124039.
  2. [2] C. Buzkan and E. Erten, “Yüksek Katlı Çelik ve Betonarme Taşıyıcı Sistemli Yapıların Yangın Davranışları Üzerine Bir Araştırma,” Ç.Ü. Fen ve Mühendislik Bilim. Derg., vol. 34, no. 2, 2016.
  3. [3] F. Kocataşkın, Yapı Malzemesi Bilimi. İstanbul: Birsen Yayınevi, 2000.
  4. [4] A. S. Abdulrahman and M. R. A. Kadir, “Behavior and flexural strength of fire damaged high strength reinforced rectangular concrete beams after strengthening with CFRP laminates,” Ain Shams Eng. J., vol. 13, no. 6, p. 101767, Nov. 2022, doi: 10.1016/J.ASEJ.2022.101767.
  5. [5] A. M. Papadopoulos, “State of the art in thermal insulation materials and aims for future developments,” Energy Build., vol. 37, no. 1, pp. 77–86, Jan. 2005, doi: 10.1016/J.ENBUILD.2004.05.006.
  6. [6] T. Vrána and K. Gudmundsson, “Comparison of fibrous insulations – Cellulose and stone wool in terms of moisture properties resulting from condensation and ice formation,” Constr. Build. Mater., vol. 24, no. 7, pp. 1151–1157, Jul. 2010, doi: 10.1016/J.CONBUILDMAT.2009.12.026.
  7. [7] X. Wu, J.-Y. Liu, X. Zhao, A.-H. Yi, and Y.-L. Wu, “Research on fire resistance performance of rock wool material element,” World Build. Mater., p. 6, 2011.
  8. [8] A. Yörükoğlu, F. Akkurt, and S. Çulha, “Investigation of boron usability in rock wool production,” Constr. Build. Mater., vol. 243, p. 118222, May 2020, doi: 10.1016/J.CONBUILDMAT.2020.118222.

Ayrıntılar

Birincil Dil

Türkçe

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

25 Mart 2023

Gönderilme Tarihi

27 Ağustos 2022

Kabul Tarihi

31 Aralık 2022

Yayımlandığı Sayı

Yıl 2023 Cilt: 11 Sayı: 1

Kaynak Göster

APA
Arslan, Ş., & Aydın, F. (2023). Experimental Investigation of the Effects of Insulation Materials and Concrete Strength on Temperature Transitions in FRP Reinforced Structural Elements Under High Temperature. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 11(1), 222-235. https://doi.org/10.29109/gujsc.1167810