Reducing the environmental impacts of energy systems and efficient use of energy are important for ecological balance. Standards and regulations in cooling systems limit the use of refrigerants, which consume energy, trap heat and increase global warming through the greenhouse effect. In refrigerated Display cabinets (RDC), there has been a recent increase in the use of natural refrigerants, especially carbon dioxide, ammonia, hydrocarbons, etc. to reduce environmental impacts. With the developing refrigeration and chemical industries, different fluids with low global warming potential (GWP) and ozone depletion potential (ODP) values have begun to be used. Today, environmentally friendly refrigerants are preferred, especially carbon dioxide CO2 (R744), which has a GWP value of 1 and an ODP value of 0, and has become an important alternative because it does not burn or ignite, and does not contain any toxic substances. In this sense in study, a compact eco-design outdoor unit containing multiple compressors was designed using CO2 (R744), an environmentally friendly natural refrigerant, for refrigerated display cabinet in positive temperature (PT) (-1 °C / +5 °C ) and negative temperature (NT) (-15 °C / -30 °C ) classes. The designed outdoor unit has the ability to synchronously operate RDCs in multiple different temperature classes in supermarkets. The designed central (remote) cooler with outdoor unit was tested in test rooms within the scope of TS EN ISO 23953-2: 2017 standard and its performance was analyzed using PS-NS compressors and multi-ejector system. Total energy consumption for coolers (indoor units) in PS and NS classes is calculated as 27.86 kWh/day and 36.1 kWh/day, respectively, and the energy classes are C and E classes, respectively. The maximum and minimum package temperatures for these coolers are in the range of -0.8 / +5 °C and -16 / -27 °C respectively. As a result of the analyses, the required cooling loads at different temperatures were met and the temperature class specified within the scope of the standard was achieved for the products cooled in the cabinet. So, with this design, supermarket etc. by eliminating the need for an outdoor unit for each different temperature in refrigerated display cabinet in sales areas, a CO2 refrigerated cooling system that provides different temperature classes with a single system has been introduced.

Keywords

Kaynakça

  1. [1] Kasap, F., Acül, H., Canbaz, H., & Erbil, S. (2011). R744 (CO2) soğutucu akışkanlı soğutma sistemleri, kanatlı borulu R744 (CO2) evaporatör ve gaz soğutucu tasarım esasları. X. Ulusal Tesisat Mühendisliği Kongresi, 1, 369-389.
  2. [2] Dai, B., Cao, Y., Zhou, X., Liu, S., Fu, R., Li, C., & Wang, D. (2024). Exergy, carbon footprint and cost lifecycle evaluation of cascade mechanical subcooling CO2 commercial refrigeration system in China. Journal of Cleaner Production, 434, 140186.
  3. [3] Sengupta, A., & Dasgupta, M. S. (2023). Energy and advanced exergoeconomic analysis of a novel ejector-based CO2 refrigeration system and its optimization for supermarket application in warm climates. Thermal Science and Engineering Progress, 44, 102056.
  4. [4] Chi, W., Yang, Q., Chen, X., Li, L., Liu, G., & Zhao, Y. (2023). Advanced exergy analysis of NH3/CO2 cascade refrigeration system with ejector. International Journal of Refrigeration, 145, 185-195.
  5. [5] Li, L., Tian, H., Liu, K., Wu, Y., Wang, X., Liang, X., & Shu, G. (2024). Optimum pressure control with three controllable ejectors of a CO2 multi-ejector refrigeration system. International Journal of Refrigeration, 157, 172-185.
  6. [6] Yang, D., Zhu, J., Wang, N., & Xie, J. (2023). Experimental study on the performance of trans-critical CO2 two-stage compression refrigeration system with and without an ejector at low temperatures. International Journal of Refrigeration, 154, 231-242.
  7. [7] Leerbeck, K., Bacher, P., Heerup, C., & Madsen, H. (2023). Grey box modeling of supermarket refrigeration cabinets. Energy and AI, 11, 100211.
  8. [8] Yilmaz, D., Mancuhan, E., & Yılmaz, B. (2020). Experimental investigation of PCM location in a commercial display cabinet cooled by a transcritical CO2 system. International Journal of Refrigeration, 120, 396-405.

Ayrıntılar

Birincil Dil

Türkçe

Konular

Enerji , Makine Tasarımı ve Makine Elemanları

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

27 Haziran 2024

Yayımlanma Tarihi

29 Haziran 2024

Gönderilme Tarihi

28 Şubat 2024

Kabul Tarihi

25 Mart 2024

Yayımlandığı Sayı

Yıl 1970 Cilt: 12 Sayı: 2

Kaynak Göster

APA
Erten, S., Öder, M., Temür, B. C., & Koç, B. (2024). TEŞHİR TİPİ SOĞUTUCULAR İÇİN CO2 SOĞUTKANLI EKO-TASARIM DIŞ ÜNİTE GELİŞTİRİLMESİ. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 12(2), 792-805. https://doi.org/10.29109/gujsc.1444507

                                     16168      16167     16166     21432        logo.png   


    e-ISSN:2147-9526