Design and Characterization of a 37 GHz Millimeter-Wave Transceiver for Dielectric-Based Sensing in Aqueous Solutions
Öz
Diabetes is a chronic disease requiring frequent monitoring of blood glucose levels, while conventional invasive techniques remain painful and inconvenient. In this work, we present a compact millimeter-wave (mm-wave) transceiver operating at 37 GHz for non-invasive glucose sensing based on variations in the dielectric properties of biological media. The proposed system operates in transmission mode using a pair of microstrip patch antennas, where changes in glucose concentration alter the complex permittivity of the medium, affecting the transmission coefficient S21. The transceiver integrates a voltage-controlled oscillator, frequency tripler, low-noise amplifier, and power detector to convert received RF power variations into a measurable DC voltage. Electromagnetic simulations demonstrate a clear sensitivity profile of 0.2434 dB per 1% glucose increment at 37 GHz, corresponding to a predicted theoretical voltage shift of 7.06 mV/%. Experimental validation using deionized water baseline tests and advanced blood mimicking protein-doped solutions demonstrates a highly linear tracking response with a measured operational sensitivity of 5.5 mV/%, revealing a system-level efficiency of 77.9% after accounting for dielectric reflection losses at the interface boundaries. Long-term characterization confirms excellent operational stability with a maximum system voltage drift of merely 0.5 mV over an 81-minute monitoring window. The platform achieves a detection resolution of approximately 200.4 mg/dL (0.2%), which is strictly bounded by the 1 mV digital quantization limitations of the readout instrumentation rather than the underlying sensor physics. These quantitative findings confirm the technical feasibility of utilizing high-frequency, mouse-sized mm-wave transceivers as an effective, low-cost path toward continuous, non-invasive personal glucose monitoring devices.
Anahtar Kelimeler
Kaynakça
- [1] A. E. Omer, S. Safavi-Naeini, R. Hughson and G. Shaker, "Blood Glucose Level Monitoring Using an FMCW Millimeter-Wave Radar Sensor," MPDI Remote Sensing, vol. 12, no. 3, pp. 123–135, 2020. W.-K. Chen, Linear Networks and Systems. Belmont, CA, USA: Wadsworth, 1993.
- [2] World Health Organization, "World Health Organization," World Health Organization, 15 May 2020. [Online]. Available: https://www.who.int/news-room/fact-sheets/detail/diabetes. [Accessed 05 Jun 2020].
- [3] T. Yilmaz, R. Foster and H. Yang , "Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels," Diagnostics, vol. 9, no. 1, p. 6, Jan. 2019.
- [4] IDF Diabetes Atlas, 11th edition," International Diabetes Federation, Brussels, Belgium, 2024. Available: IDF Diabetes Atlas.
- [5] Diabetes Canada, “Diabetes in Canada,” 2024. [Online]. Available: https://diabetes.ca/advocacy-policies/advocacy-reports/national-and-provincial-backgrounders/diabetes-in-canada.
- [6] Abbott Laboratories Limited. FreeStyle Libre. Available online: https://www.freestylelibre.co.uk/libre/ (accessed on 7May 2021).
- [7] Dexcom Inc. Dexcom. Available online: https://www.dexcom.com/ (accessed on 7 May 2021).
- [8] S. Larose, R. Rabasa-Lhoret, A. Roy-Fleming, C. Suppère, S. Tagougui, V. Messier, & N. Taleb, “Changes in Accuracy of Continuous Glucose Monitoring Using Dexcom G4 Platinum Over the Course of Moderate Intensity Aerobic Exercise in Type 1 Diabetes,” Diabetes Technol. Ther., vol. 21, no. 6 , 21, pp. 364–369, 2019. Y. Yorozu, M. Hirano, K. Oka, and Y. Tagawa, “Electron spectroscopy studies on magneto-optical media and plastic substrate interfaces (Translation Journals style),” IEEE Transl. J. Magn.Jpn., vol. 2, Aug. 1987, pp. 740–741 [Dig. 9th Annu. Conf. Magnetics Japan, 1982, p. 301].
Ayrıntılar
Birincil Dil
İngilizce
Konular
Devreler ve Sistemler, Mühendislik Elektromanyetiği
Bölüm
Araştırma Makalesi
Yazarlar
Vedat Çavlu
*
ığdır üniversitesi
0000-0002-7208-9716
Türkiye
Erken Görünüm Tarihi
23 Eylül 2026
Yayımlanma Tarihi
30 Eylül 2026
Gönderilme Tarihi
5 Haziran 2026
Kabul Tarihi
18 Eylül 2026
Yayımlandığı Sayı
Yıl 2026 Cilt: 14 Sayı: 3
