Araştırma Makalesi

A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management

Cilt: 5 Sayı: 3 10 Ekim 2023
PDF İndir
TR EN

A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management

Öz

Objective: The aim of this study is to evaluate the effects of the Coronavirus disease 2019 on sonographic optic nerve sheath diameter measurement and thus avoid possible misleading results in clinical practice. Material and Method: Each volunteer was first evaluated using carotid system color Doppler ultrasonography. Patients with a history of PCR-confirmed Coronavirus disease 2019 infection were classified as group 1 and patients without a history of Coronavirus disease 2019 infection were classified as group 2, and sonographic optic nerve sheath diameter values of both groups were analyzed. Results: Of the 123 patients included in the study, 70 (56.9%) were female and 58 (43.1%) were male. 83 (67.5%) of the patients included in the study were in group 1 and 40 (32.5%) were in group 2. The mean sonographic optic nerve sheath diameter values for the groups were 3.53 mm and 3.46 mm, respectively. The sonographic optic nerve sheath diameter differences between the two eyes for the groups were determined to be 0.203±0.139 mm and 0.282±0.2 mm. Conclusion: Due to the variable effects of Severe Acute Respiratory Syndrome Coronavirus-2, the use of sonographic optic nerve sheath diameter measurement in current standards for critical patient management may lead to false-positive or false-negative results.

Anahtar Kelimeler

Teşekkür

We thank Dr. Erdal KOMUT for his editing of the manuscript.

Kaynakça

  1. Komut E, Kozacı N, Sönmez BM, et al. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED. The American journal of emergency medicine 2016;34:963-967.
  2. Hirzallah MI, Lochner P, Hafeez MU, et al. Quality assessment of optic nerve sheath diameter ultrasonography: Scoping literature review and Delphi protocol. Journal of Neuroimaging 2022;32:808-824.
  3. Hansen H, Helmke K. The subarachnoid space surrounding the optic nerves. An ultrasound study of the optic nerve sheath. Surgical and radiologic anatomy: SRA 1996;18:323-328.
  4. Maissan IM, Dirven PJ, Haitsma IK, et al. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure. Journal of neurosurgery 2015;123:743-747.
  5. Geeraerts T, Launey Y, Martin L, et al. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive care medicine 2007;33:1704-1711.
  6. Robba C, Santori G, Czosnyka M, et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive care medicine 2018;44:1284-1294.
  7. Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive care medicine 2011;37:1059-1068.
  8. Yılmaz F, Sonmez BM, Kavalci C, Arslan ED, Caliskan G, Beydilli I. Efficacy of bedside optic nerve sheath diameter measurement in differentiating provoked seizure from unprovoked seizure in the emergency department. Annals of Saudi Medicine 2023;43:42-49.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Acil Tıp, Radyoloji ve Organ Görüntüleme

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

10 Ekim 2023

Gönderilme Tarihi

15 Ağustos 2023

Kabul Tarihi

23 Eylül 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 5 Sayı: 3

Kaynak Göster

APA
Komut, S., & Fidan, N. (2023). A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management. Hitit Medical Journal, 5(3), 202-208. https://doi.org/10.52827/hititmedj.1344000
AMA
1.Komut S, Fidan N. A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management. Hitit Medical Journal. 2023;5(3):202-208. doi:10.52827/hititmedj.1344000
Chicago
Komut, Seval, ve Nurdan Fidan. 2023. “A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management”. Hitit Medical Journal 5 (3): 202-8. https://doi.org/10.52827/hititmedj.1344000.
EndNote
Komut S, Fidan N (01 Ekim 2023) A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management. Hitit Medical Journal 5 3 202–208.
IEEE
[1]S. Komut ve N. Fidan, “A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management”, Hitit Medical Journal, c. 5, sy 3, ss. 202–208, Eki. 2023, doi: 10.52827/hititmedj.1344000.
ISNAD
Komut, Seval - Fidan, Nurdan. “A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management”. Hitit Medical Journal 5/3 (01 Ekim 2023): 202-208. https://doi.org/10.52827/hititmedj.1344000.
JAMA
1.Komut S, Fidan N. A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management. Hitit Medical Journal. 2023;5:202–208.
MLA
Komut, Seval, ve Nurdan Fidan. “A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management”. Hitit Medical Journal, c. 5, sy 3, Ekim 2023, ss. 202-8, doi:10.52827/hititmedj.1344000.
Vancouver
1.Seval Komut, Nurdan Fidan. A Pilot Study: The Effect of COVID-19 on Sonographic Optic Nerve Sheath Diameter Measured for Critical Patient Management. Hitit Medical Journal. 01 Ekim 2023;5(3):202-8. doi:10.52827/hititmedj.1344000

Cited By