Araştırma Makalesi

Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study

Cilt: 2 Sayı: 1 27 Ocak 2022
  • Mehmet Murat Uzel
  • Özgür Eroğul
  • Leyla Eryiğit Eroğul
  • Ayşe Güzin Taşlıpınar Uzel
  • Avşin İbiş
  • Hamidu Hamisi Gobeka
PDF İndir

Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study

Öz

Aside from general body fluid fluctuation, hemodialysis (HD) may cause changes in ocular fluid balance, resulting in changes in subfoveal choroidal thickness (SFCT) and other ocular parameters. As a result, the purpose of this study was to investigate the effects of hemodialysis on the reproducibility of SFCT measured by spectral domain-optical coherence tomography (SD-OCT). Twenty-six HD (26 eyes) patients had their pre- and post-HD SFCT measured, and the results were compared for reproducibility. Following a thorough ophthalmic examination, SD-OCT was performed three times in a row during a single session. The same physician measured SFCT after automatically identifying choroid with a software caliper. Reproducibility parameters, including intra-class correlation coefficients (ICCs), coefficients of variation (COV), and test-retest variability (TRTV) were then calculated. Males made up 53.85% of the 26 HD patients. There was a significant IOP difference between pre-HD (16.42±3.14 mmHg) and post-HD (14.21±2.78 mmHg) (P<0.001). SFCT decreased significantly from pre-HD 243.50±10.23 μm to post-HD 234.29±9.41 μm (P<0.001). ICC value increased significantly after HD, rising from 0.948 to 0.989 (P<0.001, for all). Pre- and post-HD COV values were 1.6% and 0.65%, respectively. Also, pre- and post-HD TRTV values were 7.864±1.996 μm and 3.074±1.536 μm, respectively. In this study, the reproducibility of SFCT as measured by OCT was lower during pre-HD compared to post-HD. Post-HD SD-OCT assessment appears to improve the reliability of clinical outcomes in the diagnosis and monitoring of HD patients.

Anahtar Kelimeler

Kaynakça

  1. 1. Chelala E, Dirani A, Fadlallah A, Slim E, Abdelmassih Y, Fakhoury H, et al. Effect of hemodialysis on visual acuity, intraocular pressure, and macular thickness in patients with chronic kidney disease. Clin Ophthalmol. 2015;9:109-14. doi: 10.2147/OPTH.S74481.
  2. 2. Mullaem G, Rosner MH. Ocular problems in the patient with end-stage renal disease. Semin Dial. 2012;25(4):403-7. doi: 10.1111/j.1525-139X.2012.01098.x.
  3. 3. Jung JW, Yoon MH, Lee SW, Chin HS. Effect of hemodialysis (HD) on intraocular pressure, ocular surface, and macular change in patients with chronic renal failure. Effect of hemodialysis on the ophthalmologic findings. Graefes Arch Clin Exp Ophthalmol. 2013;251(1):153-62. doi: 10.1007/s00417-012-2032-6.
  4. 4. Jung JW, Chin HS, Lee DH, Yoon MH, Kim NR. Changes in subfoveal choroidal thickness and choroidal extravascular density by spectral domain optical coherence tomography after haemodialysis: A pilot study. Br J Ophthalmol. 2014;98(2):207-12. doi: 10.1136/bjophthalmol-2013-303645.
  5. 5. Spaide RF. Disease expression in nonexudative age-related macular degeneration varies with choroidal thickness. Retina. 2018;38(4):708-16.doi: 10.1097/IAE.0000000000001689.
  6. 6. Huang X, Zhang P, Zou X, Xu Y, Zhu J, He J, et al. Thinner average choroidal thickness is a risk factor for the onset of diabetic retinopathy. Ophthalmic Res. 2020;63(3):259-70. doi: 10.1159/000504756.
  7. 7. Ahn SJ, Park KH, Woo SJ. Subfoveal choroidal thickness changes following anti-vascular endothelial growth factor therapy in myopic choroidal neovascularization. Invest Ophthalmol Vis Sci. 2015;56(10):5794-800. doi: 10.1167/iovs.14-16006.
  8. 8. Okamoto M, Matsuura T, Ogata N. Effects of panretinal photocoagulation on choroidal thickness and choroidal blood flow in patients with severe nonproliferative diabetic retinopathy. Retina. 2016;36(4):805-11. doi: 10.1097/IAE.0000000000000800.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Mehmet Murat Uzel Bu kişi benim
0000-0002-7420-8934
Türkiye

Leyla Eryiğit Eroğul Bu kişi benim
0000-0003-3622-2089
Türkiye

Ayşe Güzin Taşlıpınar Uzel Bu kişi benim
0000-0002-0079-5179
Türkiye

Hamidu Hamisi Gobeka Bu kişi benim
0000-0002-7656-3155
Türkiye

Yayımlanma Tarihi

27 Ocak 2022

Gönderilme Tarihi

9 Ekim 2021

Kabul Tarihi

29 Kasım 2021

Yayımlandığı Sayı

Yıl 2022 Cilt: 2 Sayı: 1

Kaynak Göster

APA
Uzel, M. M., Eroğul, Ö., Eryiğit Eroğul, L., Taşlıpınar Uzel, A. G., İbiş, A., & Gobeka, H. H. (2022). Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study. Health Sciences Quarterly, 2(1), 39-44. https://izlik.org/JA62DX82YR
AMA
1.Uzel MM, Eroğul Ö, Eryiğit Eroğul L, Taşlıpınar Uzel AG, İbiş A, Gobeka HH. Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study. Health Sci. Q. 2022;2(1):39-44. https://izlik.org/JA62DX82YR
Chicago
Uzel, Mehmet Murat, Özgür Eroğul, Leyla Eryiğit Eroğul, Ayşe Güzin Taşlıpınar Uzel, Avşin İbiş, ve Hamidu Hamisi Gobeka. 2022. “Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study”. Health Sciences Quarterly 2 (1): 39-44. https://izlik.org/JA62DX82YR.
EndNote
Uzel MM, Eroğul Ö, Eryiğit Eroğul L, Taşlıpınar Uzel AG, İbiş A, Gobeka HH (01 Ocak 2022) Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study. Health Sciences Quarterly 2 1 39–44.
IEEE
[1]M. M. Uzel, Ö. Eroğul, L. Eryiğit Eroğul, A. G. Taşlıpınar Uzel, A. İbiş, ve H. H. Gobeka, “Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study”, Health Sci. Q., c. 2, sy 1, ss. 39–44, Oca. 2022, [çevrimiçi]. Erişim adresi: https://izlik.org/JA62DX82YR
ISNAD
Uzel, Mehmet Murat - Eroğul, Özgür - Eryiğit Eroğul, Leyla - Taşlıpınar Uzel, Ayşe Güzin - İbiş, Avşin - Gobeka, Hamidu Hamisi. “Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study”. Health Sciences Quarterly 2/1 (01 Ocak 2022): 39-44. https://izlik.org/JA62DX82YR.
JAMA
1.Uzel MM, Eroğul Ö, Eryiğit Eroğul L, Taşlıpınar Uzel AG, İbiş A, Gobeka HH. Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study. Health Sci. Q. 2022;2:39–44.
MLA
Uzel, Mehmet Murat, vd. “Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study”. Health Sciences Quarterly, c. 2, sy 1, Ocak 2022, ss. 39-44, https://izlik.org/JA62DX82YR.
Vancouver
1.Mehmet Murat Uzel, Özgür Eroğul, Leyla Eryiğit Eroğul, Ayşe Güzin Taşlıpınar Uzel, Avşin İbiş, Hamidu Hamisi Gobeka. Reproducibility of choroidal thickness measurements in hemodialysis patients: A spectral domain optical coherence tomography study. Health Sci. Q. [Internet]. 01 Ocak 2022;2(1):39-44. Erişim adresi: https://izlik.org/JA62DX82YR