In this
study, the effects of pre-precipitation unit on activated sludge unit were
investigated. An aerobic activated sludge processes treating domestic
wastewater designed on the basis of theoretical calculations for two different
case – in the presence and absence of primary settler. A domestic wastewater
containing 650 and 530 mg/L total and biodegradable COD treated in an activated
sludge process in the presence and absence of primary settling respectively. It
is calculated that presence of primary settling decreased the total excess
sludge (an average 33%), total mass in the system (34%) reactor volume (34%)
and oxygen requirement (23%) in the activated sludge system. Presence of
primary settler removes a portion of total COD in the influent and therefore it
decreases the COD loading to activated sludge process.
In this
study, the effects of pre-precipitation unit on activated sludge unit were
investigated. An aerobic activated sludge processes treating domestic
wastewater designed on the basis of theoretical calculations for two different
case – in the presence and absence of primary settler. A domestic wastewater
containing 650 and 530 mg/L total and biodegradable COD treated in an activated
sludge process in the presence and absence of primary settling respectively. It
is calculated that presence of primary settling decreased the total excess
sludge (an average 33%), total mass in the system (34%) reactor volume (34%)
and oxygen requirement (23%) in the activated sludge system. Presence of
primary settler removes a portion of total COD in the influent and therefore it
decreases the COD loading to activated sludge process.
Birincil Dil | İngilizce |
---|---|
Konular | Mühendislik |
Bölüm | Makaleler |
Yazarlar | |
Yayımlanma Tarihi | 25 Aralık 2019 |
Gönderilme Tarihi | 17 Ağustos 2019 |
Kabul Tarihi | 5 Aralık 2019 |
Yayımlandığı Sayı | Yıl 2019 Cilt: 4 Sayı: 3 |