Araştırma Makalesi

A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario

Cilt: 1 Sayı: 1 18 Ağustos 2015
  • Ayten Saraçoğlu
  • Engin Hüsnü Uğur
  • Olgaç Bezen
  • Sibel Şener
  • Fisun Yüzer
  • Nüzhet Mert Şentürk
PDF İndir
TR EN

A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario

Öz

Objectives: Direct laryngoscopy is a conventional method that has been taught in endotracheal intubation training. However, it is difficult to become skilled. Videolaryngoscopy has become a widely accepted technique for training both novice and inexperienced medical staff on airway management. We aimed to compare the performances of novices using direct and indirect laryngoscopes.

Materials and methods: Fifty eight first-year anesthesia nurse students without previous tracheal intubation experience were included in the study.

Standard size 3 Macintosh, Miller, McCoy, McGrath, Storz C-Mac laryngoscopes were used. The participants were asked to intubate the AirMan manikin five times with each device. The participants were also asked for their familiarity with computer games. After all the students completed their fifth intubations; the duration of successful tracheal intubation, number of attempts, success rate, severity of the dental trauma, and the used optimization maneuvers were recorded in the course of students’ sixth intubations.

Results: Time to successful intubation was the shortest for C-Mac laryngoscope with 5.34±2.19 sec. The requirement of optimization maneuvers (12.1%) and additional intubation attempts (1.7%) were significantly lower with C-Mac and McGrath laryngoscopes compared to Macintosh, Miller and McCoy laryngoscopes (p<0.001). Dental trauma incidence was significantly lower during the use of C-Mac laryngoscope (p<0.001). The VAS score on the ease of intubation were significantly lower with C-Mac laryngoscope. No advantages related to the familiarity with computer games were documented.

Conclusion: In conclusion, C-Mac was observed to provide a higher overall success rate for tracheal intubation and less dental trauma incidence when it was used in a normal airway scenario.

Anahtar Kelimeler

Kaynakça

  1. Mosier J, Chiu S, Patanwala AE, Sakles JC. A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department. Ann Emerg Med 2013;61:414-420.
  2. Wang HE, Seitz SR, Hostler D, Yealy DM. Defining the learning curve for paramedic student endotracheal intubation. Prehosp Emerg Care 2005;9:156-62.
  3. Mulcaster JT, Mills J, Hung OR, MacQuarrie K, Law JA, Pytka S, et al. Laryngoscopic intubation: learning and performance. Anesthesiology 2003;98:23-7.
  4. Sethuraman D, Darshane S, Guha A, Charters P. A randomised, crossover study of the Dorges, McCoy and Macintosh laryngoscope blades in a simulated difficult intubation scenario. Anaesthesia 2006;61:482-7.
  5. Nouruzi-Sedeh P, Schumann M, Groeben H. Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology 2009;110:32-7.
  6. Miki T, Inagawa G, Kikuchi T, Koyama Y, Goto T. Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naive operators: a manikin study. Acta Anaesthesiol Scand 2007;51:1378-81.
  7. Woollard M, Mannion W, Lighton D, Johns I, O'meara P, Cotton C, et al. Use of the Airtraq laryngoscope in a model of difficult intubation by prehospital providers not previously trained in laryngoscopy. Anaesthesia 2007;62:1061-5.
  8. Wetsch WA, Hellmich M, Spelten O, Schier R, Böttiger BW, Hinkelbein J. Tracheal intubation in the ice-pick position with video laryngoscopes: a randomised controlled trial in a manikin. Eur J Anaesthesiol 2013;30:537-43.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Ayten Saraçoğlu Bu kişi benim

Engin Hüsnü Uğur Bu kişi benim

Olgaç Bezen Bu kişi benim

Sibel Şener Bu kişi benim

Fisun Yüzer Bu kişi benim

Nüzhet Mert Şentürk Bu kişi benim

Yayımlanma Tarihi

18 Ağustos 2015

Gönderilme Tarihi

18 Ağustos 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2015 Cilt: 1 Sayı: 1

Kaynak Göster

APA
Saraçoğlu, A., Uğur, E. H., Bezen, O., Şener, S., Yüzer, F., & Şentürk, N. M. (2015). A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi, 1(1), 1-6. https://doi.org/10.5606/fng.btd.2015.001
AMA
1.Saraçoğlu A, Uğur EH, Bezen O, Şener S, Yüzer F, Şentürk NM. A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi. 2015;1(1):1-6. doi:10.5606/fng.btd.2015.001
Chicago
Saraçoğlu, Ayten, Engin Hüsnü Uğur, Olgaç Bezen, Sibel Şener, Fisun Yüzer, ve Nüzhet Mert Şentürk. 2015. “A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario”. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi 1 (1): 1-6. https://doi.org/10.5606/fng.btd.2015.001.
EndNote
Saraçoğlu A, Uğur EH, Bezen O, Şener S, Yüzer F, Şentürk NM (01 Ağustos 2015) A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi 1 1 1–6.
IEEE
[1]A. Saraçoğlu, E. H. Uğur, O. Bezen, S. Şener, F. Yüzer, ve N. M. Şentürk, “A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario”, İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi, c. 1, sy 1, ss. 1–6, Ağu. 2015, doi: 10.5606/fng.btd.2015.001.
ISNAD
Saraçoğlu, Ayten - Uğur, Engin Hüsnü - Bezen, Olgaç - Şener, Sibel - Yüzer, Fisun - Şentürk, Nüzhet Mert. “A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario”. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi 1/1 (01 Ağustos 2015): 1-6. https://doi.org/10.5606/fng.btd.2015.001.
JAMA
1.Saraçoğlu A, Uğur EH, Bezen O, Şener S, Yüzer F, Şentürk NM. A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi. 2015;1:1–6.
MLA
Saraçoğlu, Ayten, vd. “A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario”. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi, c. 1, sy 1, Ağustos 2015, ss. 1-6, doi:10.5606/fng.btd.2015.001.
Vancouver
1.Ayten Saraçoğlu, Engin Hüsnü Uğur, Olgaç Bezen, Sibel Şener, Fisun Yüzer, Nüzhet Mert Şentürk. A randomized, crossover model-based study of five different laryngoscopes in normal airway scenario. İstanbul Bilim Üniversitesi Florence Nightingale Tıp Dergisi. 01 Ağustos 2015;1(1):1-6. doi:10.5606/fng.btd.2015.001