Araştırma Makalesi

Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism

Sayı: 18 31 Aralık 2022
PDF İndir
TR EN

Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism

Öz

Aim: Autism Spectrum Disorder (ASD) is a developmental disorder that can present with an abnormality of the autonomic nervous system (ANS symptoms).
Method: In this study, 38 eyes of 19 ASD were included with 19 healthy children (control group). Participants were analyzed according to their characteristics. Here, used the Plusoptix A09 devices to measure the difference in pupil size, corneal reflex, and interpupillary distance (IPD) between ASD and healthy children.
Results: The mean age±standard deviation (SD) for the autism group was 4,6±2,5 years (range 2-11 years). In the group of normally developing children, the mean age was±SD 5,02±2,6 years (range 2-11 years). The size of the right pupil (p=0,006) and left pupil (p=0,007) was found to be significantly different in the control and experimental groups. IPD (p=0,000) was statistically significant between groups unlike the corneal reflex was not (p=0,173). The p-value is less than 0,05 in all statistical results.
Conclusion: As a result, pupil diameter and IPD of children with autism were found to be larger than the control group, but there was no significant difference in corneal reflex. Pupillary measurements reveal differences between people with ASD.  

Anahtar Kelimeler

Kaynakça

  1. Centers for Disease Control and Prevention. Data & Statistics on Autism Spectrum Disorder. Centers for Disease Control and Prevention. https://www.cdc.gov/ncbddd/autism/data.html Published in March 2022. Accessed on March 2022.
  2. Dawson G, Lewy A. Arousal, attention, and the socioemotional impairments of individuals with autism. In: Dawson G, ed. Autism: Nature, Diagnosis, and Treatment. New York: Guilford Press;1989:49-74.
  3. Goodwin MS, Groden J, Velicer WF, Lipsitt LP, Baron MG, Hofmann SG. Cardiovascular arousal in individuals with autism. Focus. 2006;21(2):100–123. doi:10.1177/10883576060210020101
  4. Binda P, Gamlin PD. Renewed attention on the pupil light reflex. Trends Neurosciences. 2017;40(8):455–457. doi:10.1016/j.tins.2017.06.007
  5. Cordonnier M, Kallay O. Non-cycloplegic screening for refractive errors in children with the hand-held autorefractor Retinomax: Final results and comparison with noncycloplegic photoscreening. Strabismus. 2001;9(2):59–70. doi:10.1076/stra.9.2.59.701
  6. Matta NS, Singman EL, Silbert DI. Performance of the Plusoptix vision screener for the detection of amblyopia risk factors in children. Journal of American Association for Pediatric Ophthalmology and Strabismus. 2008;12(5):490–492. doi:10.1016/j.jaapos.2008.04.004
  7. Payerols A, Eliaou C, Trezeguet V, Villain M, Daien V. Accuracy of PlusOptix A09 distance refraction in pediatric myopia and hyperopia. BMC Ophthalmology. 2016;16:72-8. doi:10.1186/s12886-016-0247-8
  8. Yan XR, Jiao WZ, Li ZW, Xu WW, Li FJ, Wang LH. Performance of the Plusoptix A09 photo screener in detecting amblyopia risk factors in Chinese children attending an eye clinic. PLoS One. 2015;10(6):e0126052. doi:10.1371/journal.pone.0126052

Ayrıntılar

Birincil Dil

İngilizce

Konular

Klinik Tıp Bilimleri

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Aralık 2022

Gönderilme Tarihi

16 Mart 2022

Kabul Tarihi

12 Aralık 2022

Yayımlandığı Sayı

Yıl 2022 Sayı: 18

Kaynak Göster

APA
Şahbaz, İ., Taşdöndüren, E., Özcan, Ö. Ö., Erguzel, T., Karahan, M., Konuk, M., & Tarhan, N. (2022). Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism. Istanbul Gelisim University Journal of Health Sciences, 18, 668-677. https://doi.org/10.38079/igusabder.1088174
AMA
1.Şahbaz İ, Taşdöndüren E, Özcan ÖÖ, vd. Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism. IGUSABDER. 2022;(18):668-677. doi:10.38079/igusabder.1088174
Chicago
Şahbaz, İbrahim, Emre Taşdöndüren, Öznur Özge Özcan, vd. 2022. “Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism”. Istanbul Gelisim University Journal of Health Sciences, sy 18: 668-77. https://doi.org/10.38079/igusabder.1088174.
EndNote
Şahbaz İ, Taşdöndüren E, Özcan ÖÖ, Erguzel T, Karahan M, Konuk M, Tarhan N (01 Aralık 2022) Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism. Istanbul Gelisim University Journal of Health Sciences 18 668–677.
IEEE
[1]İ. Şahbaz vd., “Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism”, IGUSABDER, sy 18, ss. 668–677, Ara. 2022, doi: 10.38079/igusabder.1088174.
ISNAD
Şahbaz, İbrahim - Taşdöndüren, Emre - Özcan, Öznur Özge - Erguzel, Turker - Karahan, Mesut - Konuk, Muhsin - Tarhan, Nevzat. “Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism”. Istanbul Gelisim University Journal of Health Sciences. 18 (01 Aralık 2022): 668-677. https://doi.org/10.38079/igusabder.1088174.
JAMA
1.Şahbaz İ, Taşdöndüren E, Özcan ÖÖ, Erguzel T, Karahan M, Konuk M, Tarhan N. Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism. IGUSABDER. 2022;:668–677.
MLA
Şahbaz, İbrahim, vd. “Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism”. Istanbul Gelisim University Journal of Health Sciences, sy 18, Aralık 2022, ss. 668-77, doi:10.38079/igusabder.1088174.
Vancouver
1.İbrahim Şahbaz, Emre Taşdöndüren, Öznur Özge Özcan, Turker Erguzel, Mesut Karahan, Muhsin Konuk, Nevzat Tarhan. Comparison of Interpupillary Distance, Pupillary Diameter and Corneal Reflex Measured with Plusoptix A09 in Normally Developing Children and Autism. IGUSABDER. 01 Aralık 2022;(18):668-77. doi:10.38079/igusabder.1088174

Cited By

 Alıntı-Gayriticari-Türetilemez 4.0 Uluslararası (CC BY-NC-ND 4.0)