RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING

Cilt: 2 Sayı: 3 1 Aralık 2012
  • Ezgi Korkmaz
  • Meltem Vatan
PDF İndir
EN

RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING

Öz

There is a big stock of historic structures in Turkey. Many of those structures continue to serve by changing their functions which brings new loads to the building. During their long life, historic structures have experienced many actions occurred over long periods of time and endured long term deteriorating effects and earthquake loads, besides these effects changing of the function affects the load bearing capacity of the building. This study is focused on restoration and retrofitting of historic multi storey masonry building named Deniz Palace Building which is located in Istanbul where the whole city is seismic prone area itself. Earthquake resistance is the main purpose of decision for retrofitting and strengthening of the building. In this sense walls are sheathed by concrete, floors are strengthened by steel I profiles and concrete, and foundations are reconstructed. During the restoration, interventions are made based on prevention of historic values. Static calculations are done particularly. For this purpose, foundation retrofitting is made primarily and some critical walls are sheathed by concrete. Fire protection system is designed and according to the evacuation plan some additions such as elevator shaft are constructed

Anahtar Kelimeler

Kaynakça

  1. Kelley, S. J., Standards for Preservation
  2. and Rehabilitation, West Conshohocken, PA, ASTM, 1996.
  3. Guh, T. J., Altoontash, A., Seismic Retrofit of Historic Building Structures, 8th National
  4. Engineering, April 18-22, 2006, San Francisco, California, USA.
  5. Cheung, M., Foo, S., Granadino, J., Seismic Retrofit of Existing Buildings: Innovative Alternatives.
  6. Kubin, J., Depreme Dayanıklı Yapı Tasarımı ve Onarım/Güçlendirme Teknikleri, Sanal Gazete Yıl:5, Sayı:1, Mart 2000.
  7. Recommendations for the Analysis, Conservation and Structural Restoration of Architectural Restoration of Architectural Heritage, ICOMOS-ISCARSAH, 2005.
  8. El Gawady, M., Lestuzzi, P., Badoux, M., A Review of Conventional Seismic Retrofitting Techniques for URM, 13thInternational Brick and Block Masonry Conference Amsterdam, July 4-7, 2004.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Ezgi Korkmaz Bu kişi benim

Meltem Vatan Bu kişi benim

Yayımlanma Tarihi

1 Aralık 2012

Gönderilme Tarihi

1 Aralık 2012

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2012 Cilt: 2 Sayı: 3

Kaynak Göster

APA
Korkmaz, E., & Vatan, M. (2012). RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING. International Journal of Electronics Mechanical and Mechatronics Engineering, 2(3), 269-278. https://izlik.org/JA77BK64WJ
AMA
1.Korkmaz E, Vatan M. RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING. IJEMME. 2012;2(3):269-278. https://izlik.org/JA77BK64WJ
Chicago
Korkmaz, Ezgi, ve Meltem Vatan. 2012. “RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING”. International Journal of Electronics Mechanical and Mechatronics Engineering 2 (3): 269-78. https://izlik.org/JA77BK64WJ.
EndNote
Korkmaz E, Vatan M (01 Aralık 2012) RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING. International Journal of Electronics Mechanical and Mechatronics Engineering 2 3 269–278.
IEEE
[1]E. Korkmaz ve M. Vatan, “RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING”, IJEMME, c. 2, sy 3, ss. 269–278, Ara. 2012, [çevrimiçi]. Erişim adresi: https://izlik.org/JA77BK64WJ
ISNAD
Korkmaz, Ezgi - Vatan, Meltem. “RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING”. International Journal of Electronics Mechanical and Mechatronics Engineering 2/3 (01 Aralık 2012): 269-278. https://izlik.org/JA77BK64WJ.
JAMA
1.Korkmaz E, Vatan M. RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING. IJEMME. 2012;2:269–278.
MLA
Korkmaz, Ezgi, ve Meltem Vatan. “RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING”. International Journal of Electronics Mechanical and Mechatronics Engineering, c. 2, sy 3, Aralık 2012, ss. 269-78, https://izlik.org/JA77BK64WJ.
Vancouver
1.Ezgi Korkmaz, Meltem Vatan. RETROFITTING DENIZ PALACE HISTORIC BUILDING FOR REUSING. IJEMME [Internet]. 01 Aralık 2012;2(3):269-78. Erişim adresi: https://izlik.org/JA77BK64WJ