Abstract

In this paper, the behaviour of a wind energy conversion system that uses the structure of Doubly-Fed Induction Generator (DFIG) under faulty conditions is presented. DFIG consists of an asynchronous machine, in which the stator is connected directly to the grid and its rotor is connected to the grid via two electronic power converters (back-to-back converter). In the three-phase rectifier and the inverter with IGBTs the Pulse Width Modulation (PWM) technique is used. DFIG is analysed and simulated under faulty conditions in the environment of  Matlab/Simulink.  The faults that are investigated in this work take place in the part of the back-to-back converter (either in the rectifier or in the inverter). More specifically, it is investigated how DFIG reacts when an open circuit happens in two IGBTs of the rectifier or of the inverter. Also, the results of Fourier analysis of some important system variables in these faulty conditions are presented and an identification of these faults is done.

Keywords

Kaynakça

  1. R. Pena, J. C. Clare, and G. M. Asher, “Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation,” IEE Proc. Electr. Power Appl., vol. 143, pp. 231-241, May 1996.
  2. D. G. Giaourakis, A. Safacas, “Review of Wind Energy Conversion Systems for Large Wind Turbines and Simulation of a back-to-back Electronic Power Converter”, Ever2011, Monte Carlo, Monaco, 31 March- 3 April 2011, conference proceedings.
  3. Ned Mohan, Ted K. A. Brekken, “Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions”, IEEE Transaction Energy conversion, vol.no22. 1, march 2007 page 129-135.
  4. H. Polinder and J. Morren, “Developments in wind systems”, turbine
  5. Hammamet, Tunisia, conference proceedings. Electrimacs
  6. , [5] Muller S, Deicke M., Rik W., Doncker D.: “Doubly fed induction generator systems for wind turbines”, IEEE Trans Inds. Appl., Magazine 8 (3) (May/June 2002), pp. 26-33.
  7. Ribrant J., Bertling L., “Survey of failures in wind power systems with focus on Swedish wind power plants during 1997-2005”, Power
  8. Meeting, 2007. IEEE , pp 1-8.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Dimitrios G Giaourakis Bu kişi benim

Athanasios N Safacas Bu kişi benim

Savvas N Tsotoulidis Bu kişi benim

Yayımlanma Tarihi

1 Haziran 2012

Gönderilme Tarihi

3 Şubat 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2012 Cilt: 2 Sayı: 2

Kaynak Göster

APA
Giaourakis, D. G., Safacas, A. N., & Tsotoulidis, S. N. (2012). Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions. International Journal Of Renewable Energy Research, 2(2), 227-235. https://izlik.org/JA37BX49NY
AMA
1.Giaourakis DG, Safacas AN, Tsotoulidis SN. Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions. International Journal Of Renewable Energy Research. 2012;2(2):227-235. https://izlik.org/JA37BX49NY
Chicago
Giaourakis, Dimitrios G, Athanasios N Safacas, ve Savvas N Tsotoulidis. 2012. “Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions”. International Journal Of Renewable Energy Research 2 (2): 227-35. https://izlik.org/JA37BX49NY.
EndNote
Giaourakis DG, Safacas AN, Tsotoulidis SN (01 Haziran 2012) Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions. International Journal Of Renewable Energy Research 2 2 227–235.
IEEE
[1]D. G. Giaourakis, A. N. Safacas, ve S. N. Tsotoulidis, “Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions”, International Journal Of Renewable Energy Research, c. 2, sy 2, ss. 227–235, Haz. 2012, [çevrimiçi]. Erişim adresi: https://izlik.org/JA37BX49NY
ISNAD
Giaourakis, Dimitrios G - Safacas, Athanasios N - Tsotoulidis, Savvas N. “Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions”. International Journal Of Renewable Energy Research 2/2 (01 Haziran 2012): 227-235. https://izlik.org/JA37BX49NY.
JAMA
1.Giaourakis DG, Safacas AN, Tsotoulidis SN. Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions. International Journal Of Renewable Energy Research. 2012;2:227–235.
MLA
Giaourakis, Dimitrios G, vd. “Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions”. International Journal Of Renewable Energy Research, c. 2, sy 2, Haziran 2012, ss. 227-35, https://izlik.org/JA37BX49NY.
Vancouver
1.Dimitrios G Giaourakis, Athanasios N Safacas, Savvas N Tsotoulidis. Dynamic Behaviour of a Wind Energy Conversion System including Doubly-Fed Induction Generator in Fault Conditions. International Journal Of Renewable Energy Research [Internet]. 01 Haziran 2012;2(2):227-35. Erişim adresi: https://izlik.org/JA37BX49NY