Klinik Araştırma

COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY

Cilt: 86 Sayı: 2 30 Mart 2023
PDF İndir
TR EN

COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY

Öz

Objective: We evaluated a free-hand technique and a three-dimensional computerized tomography (3D-CT)-assisted navigation technique, which are pedicle screw placement techniques used in spinal surgery, regarding screw placement and reliability. Materials and Methods: A total of 1664 screws in 73 patients with spinal deformities who underwent spinal instrumentation using pedicle screws were evaluated in this study. Forty patients were in the free-hand technique group, and 33 patients were in the 3D-CT-assisted navigation technique group. The placement and reliability of pedicle screws in all patients were evaluated using the Gertzbein–Robbins classification using CT images taken in the postoperative period. Result: There were no significant differences found regarding age, body mass index (BMI), sex (female or male), or deformity (scoliosis or kyphosis) (p>0.05). When the pedicle screws were evaluated in terms of transverse penetration, the 3D-CT-assisted navigation technique was determined Grade A (89.6%), as was the free-hand technique (76.5%), but the 3D-CT-assisted navigation technique was statistically more reliable (p<0.001). When the pedicle screws were evaluated in terms of anterior penetration, both the 3D-CT-assisted navigation technique (92.5%) and the free-hand technique (82.9%) were determined Grade A, but the 3D-CT-assisted navigation technique was statistically more reliable (p<0.001). Conclusion: According to our study’s results, the 3D-CT-assisted navigation technique is more reliable than the free-hand technique in surgeries involving spine deformities for pedicle screw insertion.

Anahtar Kelimeler

Kaynakça

  1. 1. Serhan H, Kuhn M. The history of spinal deformity. Ann Orthop Rheumatol 2016;4(3):1072. [CrossRef] google scholar
  2. 2. Harrington PR. Treatment of scoliosis. Correction and internal fixation by spinal instrumentation, J Bone Joint Surg Am 1962;44-A:591-610. [CrossRef] google scholar
  3. 3. Perna F, Borghi R, Pilla F, Stefanini N, Mazzotti A, Chehrassan M. Pedicle screw insertion techniques: an update and review of the literature. Musculoskelet Surg 2016;100(3):165-9. [CrossRef] google scholar
  4. 4. Ughwanogho E, Patel NM, Baldwin KD, Sampson NR, Flynn JM. Computed tomography-guided navigation of thoracic pedicle screws for adolescent idiopathic scoliosis results in more accurate placement and less screw removal. Spine (Phila Pa 1976) 2012;37(8):E473-8. [CrossRef] google scholar
  5. 5. Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 2007;32(3):E111-20. [CrossRef] google scholar
  6. 6. Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 1990;15(1):11-4. [CrossRef] google scholar
  7. 7. Farrokhi MR, Kazemi AP, Eftekharian HR, Akbari K, Efficacy of prophylactic low dose of tranexamic acid in spinal fixation surgery: a randomized clinical trial. J Neurosurg Anesthesiol 2011;23(4):290-6. [CrossRef] google scholar
  8. 8. Barney LF. Scoliosis and kyphosis. In: Canale ST, Beaty JH, editors. Campbell’s Operative Orthopaedics 11. Edition, Philadelphia:Mosby 2008.p1944-5. google scholar

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Klinik Araştırma

Yayımlanma Tarihi

30 Mart 2023

Gönderilme Tarihi

3 Kasım 2022

Kabul Tarihi

28 Şubat 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 86 Sayı: 2

Kaynak Göster

APA
Çetiner, E., Yerebakan Akesen, S., Bilgin, Y., Önder, C., Güler, S. B., & Akesen, B. (2023). COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY. Journal of Istanbul Faculty of Medicine, 86(2), 138-144. https://doi.org/10.26650/IUITFD.1198451
AMA
1.Çetiner E, Yerebakan Akesen S, Bilgin Y, Önder C, Güler SB, Akesen B. COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY. İst Tıp Fak Derg. 2023;86(2):138-144. doi:10.26650/IUITFD.1198451
Chicago
Çetiner, Eyyüp, Selcan Yerebakan Akesen, Yücel Bilgin, Cem Önder, Saltuk Buğra Güler, ve Burak Akesen. 2023. “COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY”. Journal of Istanbul Faculty of Medicine 86 (2): 138-44. https://doi.org/10.26650/IUITFD.1198451.
EndNote
Çetiner E, Yerebakan Akesen S, Bilgin Y, Önder C, Güler SB, Akesen B (01 Mart 2023) COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY. Journal of Istanbul Faculty of Medicine 86 2 138–144.
IEEE
[1]E. Çetiner, S. Yerebakan Akesen, Y. Bilgin, C. Önder, S. B. Güler, ve B. Akesen, “COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY”, İst Tıp Fak Derg, c. 86, sy 2, ss. 138–144, Mar. 2023, doi: 10.26650/IUITFD.1198451.
ISNAD
Çetiner, Eyyüp - Yerebakan Akesen, Selcan - Bilgin, Yücel - Önder, Cem - Güler, Saltuk Buğra - Akesen, Burak. “COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY”. Journal of Istanbul Faculty of Medicine 86/2 (01 Mart 2023): 138-144. https://doi.org/10.26650/IUITFD.1198451.
JAMA
1.Çetiner E, Yerebakan Akesen S, Bilgin Y, Önder C, Güler SB, Akesen B. COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY. İst Tıp Fak Derg. 2023;86:138–144.
MLA
Çetiner, Eyyüp, vd. “COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY”. Journal of Istanbul Faculty of Medicine, c. 86, sy 2, Mart 2023, ss. 138-44, doi:10.26650/IUITFD.1198451.
Vancouver
1.Eyyüp Çetiner, Selcan Yerebakan Akesen, Yücel Bilgin, Cem Önder, Saltuk Buğra Güler, Burak Akesen. COMPARING THE TRAJECTORY ACCURACY OF PEDICLE SCREWS PLACED WITH A FREE-HAND TECHNIQUE AND A THREE-DIMENSIONAL COMPUTED TOMOGRAPHY-ASSISTED NAVIGATION SYSTEM IN SPINE SURGERY: A RETROSPECTIVE STUDY. İst Tıp Fak Derg. 01 Mart 2023;86(2):138-44. doi:10.26650/IUITFD.1198451

Contact information and address

Addressi: İ.Ü. İstanbul Tıp Fakültesi Dekanlığı, Turgut Özal Cad. 34093 Çapa, Fatih, İstanbul, TÜRKİYE

Email: itfdergisi@istanbul.edu.tr

Phone: +90 212 414 21 61