Araştırma Makalesi

COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY

Cilt: 89 Sayı: 3 14 Ağustos 2026
PDF İndir
TR EN

COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY

Öz

Purpose: To compare patient radiation exposure between biplane and monoplane digital subtraction angiography (DSA) systems during diagnostic cerebral angiography and evaluate the dose-efficiency of modern dual-plane technology. Material-Methods: This retrospective single-center study included 61 consecutive patients who underwent diagnostic cerebral DSA between November 2021 and April 2022. Examinations were performed using a Siemens Artis Zee monoplane system (n = 31) and a Philips Azurion ClarityIQ biplane system (n = 30). For each procedure, total fluoroscopy time, fluoroscopy dose-area product (DAP), exposure DAP, total DAP, and cumulative air kerma were recorded. Groups were compared using independent-samples t-tests or Mann–Whitney U tests, with p < 0.05 considered statistically significant. Results: Fluoroscopy time was comparable between the monoplane and biplane groups (p = 0.736). The biplane system produced a significantly greater number of image acquisitions (p < 0.001) yet achieved markedly lower radiation doses. Median exposure DAP and total DAP were reduced by approximately 25–35%, and total air kerma was significantly lower in the biplane group (p < 0.001). Fluoroscopy DAP was slightly higher for the biplane system (p = 0.008), likely reflecting occasional dual-plane use during complex catheter navigation. Conclusion: Despite acquiring more projections, the biplane DSA system demonstrated substantially lower total radiation exposure compared with the monoplane system. These results indicate that modern biplane technology with advanced dose-reduction algorithms (ClarityIQ) offers improved dose efficiency and enhanced patient safety in diagnostic cerebral angiography.

Anahtar Kelimeler

Etik Beyan

This retrospective study was approved by the Ethics Committee of Istanbul University (Approval No: 1596135).

Kaynakça

  1. Crummy AB, Strother CM, Mistretta CA. The history of digital subtraction angiography. J Vasc Interv Radiol 2018;29(8):1138-41. google scholar
  2. Summerlin D, Willis J, Boggs R, Johnson LM, Porter KK. Radiation dose reduction opportunities in vascular imaging. Tomography 2022;8(5):2618-2638. google scholar
  3. Suh SH. Striving to improve image quality and minimize radiation dose in neurointerventional procedures. Neurointervention 2025;20(2):49-51. google scholar
  4. Stephenson TF. Non-isocentric applications of biplane digital subtraction angiography. Comput Radiol 1985;9(6):399-404. google scholar
  5. Sadick V, Trinh L, Fernandes G, Pau P, Spiteri M, Vu LA, et al. Does biplane imaging reduce contrast load, procedural and screening time compared to single-plane imaging in routine diagnostic coronary angiography? Radiographer 2008;55(1):20-4. google scholar
  6. Andres C, Agulla M, Torres R, Perez-Garcia H, del Castillo A, Miguel D, et al. Patient doses in a biplane angiography system. Physica Medica 2016;32(3):307 google scholar
  7. van Asch CJ, Velthuis BK, Rinkel GJ, Algra A, de Kort GA, Witkamp TD, et al. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: prospective, multicentre cohort study. BMJ 2015;351:h5762. google scholar
  8. Nickoloff EL, Lu ZF, Dutta AK, So JC. Radiation dose descriptors: BERT, COD, DAP, and other strange creatures. Radiographics 2008;28(5):1439-50. google scholar

Ayrıntılar

Birincil Dil

İngilizce

Konular

Radyoloji ve Organ Görüntüleme, Tanı Radyografisi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

14 Ağustos 2026

Gönderilme Tarihi

22 Kasım 2025

Kabul Tarihi

2 Temmuz 2026

Yayımlandığı Sayı

Yıl 2026 Cilt: 89 Sayı: 3

Kaynak Göster

APA
Ayyıldız, H., Karabulut, M. M., Ersoy, B., & Barburoğlu, M. (2026). COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY. Journal of Istanbul Faculty of Medicine, 89(3), 199-204. https://izlik.org/JA38JF84NB
AMA
1.Ayyıldız H, Karabulut MM, Ersoy B, Barburoğlu M. COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY. İst Tıp Fak Derg. 2026;89(3):199-204. https://izlik.org/JA38JF84NB
Chicago
Ayyıldız, Hakan, Mücahit Mustafa Karabulut, Berke Ersoy, ve Mehmet Barburoğlu. 2026. “COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY”. Journal of Istanbul Faculty of Medicine 89 (3): 199-204. https://izlik.org/JA38JF84NB.
EndNote
Ayyıldız H, Karabulut MM, Ersoy B, Barburoğlu M (01 Ağustos 2026) COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY. Journal of Istanbul Faculty of Medicine 89 3 199–204.
IEEE
[1]H. Ayyıldız, M. M. Karabulut, B. Ersoy, ve M. Barburoğlu, “COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY”, İst Tıp Fak Derg, c. 89, sy 3, ss. 199–204, Ağu. 2026, [çevrimiçi]. Erişim adresi: https://izlik.org/JA38JF84NB
ISNAD
Ayyıldız, Hakan - Karabulut, Mücahit Mustafa - Ersoy, Berke - Barburoğlu, Mehmet. “COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY”. Journal of Istanbul Faculty of Medicine 89/3 (01 Ağustos 2026): 199-204. https://izlik.org/JA38JF84NB.
JAMA
1.Ayyıldız H, Karabulut MM, Ersoy B, Barburoğlu M. COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY. İst Tıp Fak Derg. 2026;89:199–204.
MLA
Ayyıldız, Hakan, vd. “COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY”. Journal of Istanbul Faculty of Medicine, c. 89, sy 3, Ağustos 2026, ss. 199-04, https://izlik.org/JA38JF84NB.
Vancouver
1.Hakan Ayyıldız, Mücahit Mustafa Karabulut, Berke Ersoy, Mehmet Barburoğlu. COMPARATIVE ANALYSIS OF RADIATION EXPOSURE IN BIPLANE VERSUS MONOPLANE CEREBRAL ANGIOGRAPHY: A SINGLE-CENTER RETROSPECTIVE STUDY. İst Tıp Fak Derg [Internet]. 01 Ağustos 2026;89(3):199-204. Erişim adresi: https://izlik.org/JA38JF84NB

Contact information and address

Addressi: İ.Ü. İstanbul Tıp Fakültesi Dekanlığı, Turgut Özal Cad. 34093 Çapa, Fatih, İstanbul, TÜRKİYE

Email: itfdergisi@istanbul.edu.tr

Phone: +90 212 414 21 61