TR
EN
Investigation of The Standardization Method with Scattered X-Rays in Matrices Prepared with Different Diluters
Abstract
In this study, it is considered to evaluate the spectral intensity ratios for different matrices to be prepared using MnO2 and boric acid, sugar, starch and cellulose as binders. The areas under the Compton and coherent scattering peaks with Mn K X-ray were calculated and the relationship between different intensity ratios and the mean atomic number of diluted samples was investigated. 100 mCi Am-241point radioactive source was used to excite the targets. The emitted and scattered X-rays from targets were counted by a ULEGe detector. The changes in the scattering intensity ratios of the mean atomic numbers of the matrices prepared using different diluents were plotted graphically, the calibration curves and correlation coefficients obtained were interpreted. In addition, there is a third-degree polynomial relationship between Icoh+IComp/(μ/ρ)(Kα) intensity ratio of the prepared sample group and mean atomic number. The obtained calibration curves can be used for qualitative analysis in sample groups with the same matrix.
Keywords
Kaynakça
- Bauer, L.J., Wieder, F., Truong, V., Förste, F., Wagener, Y., Jonas, A., Praetz, S., Schlesiger, C., Kupsch, A., Müller, B.R., Kanngießer, B., Zaslansky, P., Mantouvalou, I., (2024). Absorption Correction for 3D Elemental Distributions of Dental Composite Materials Using Laboratory Confocal Micro-X-ray Fluorescence Spectroscopy. Analytical Chemistry, 96, 8441–8449. https://doi.org/10.1021/acs.analchem.4c00116.
- Bowers, C., (2019). Matrix Effect Corrections in X-ray Fluorescence Spectrometry. Journal of Chemical Education, 96, 2597–2599. https://doi.org/10.1021/acs.jchemed.9b00630.
- Büyükyıldız, M., (2016). Determination of the effective atomic numbers of FexCu1-x binary ferroalloys using a nondestructive technique: Rayleigh-to-Compton scattering ratio. Turk J. Phys. 40, 278-286. 10.3906/fiz-1603-25.
- Chebakova, K.A., Dzidziguri, E.L., Sidorova, E.N., Vasiliev, A.A., Ozherelkov, D.Y., Pelevin, I.A., Gromov, A.A., Nalivaiko, A.Y., (2021). X-ray Fluorescence Spectroscopy Features of Micro- and Nanoscale Copper and Nickel Particle Compositions. Nanomaterials, 11, 2388. https://doi.org/10.3390/nano11092388.
- Bertin, E.P., (1975). Principles and Practice of X-Ray Spectrometric Analysis. Plenum Press. Finkel’shtein, A.L., Gunicheva, T.N., (2008). Description of the dependence of intensity of x-ray fluorescence on the particle size of powder samples and pulp during x-ray fluorescent analysis. Inorganic Materials, 44, 1567–1571. https://doi.org/10.1134/S0020168508140136.
- Hila, F.C., Asuncion-Astronomo, A., Dingle, C.A.M., Jecong, J.F.M., Javier-Hila, A.M. V., Gili, M.B.Z., Balderas, C. V., Lopez, G.E.P., Guillermo, N.R.D., Amorsolo, A. V., (2021). EpiXS: A Windows-based program for photon attenuation, dosimetry and shielding based on EPICS2017 (ENDF/B-VIII) and EPDL97 (ENDF/B-VI.8). Radiation Physics and Chemistry, 182, 109331. https://doi.org/10.1016/j.radphyschem.2020.109331.
- Hodoroaba, V.D., Rackwitz, V., (2014). Gaining improved chemical composition by exploitation of Compton-to-Rayleigh intensity ratio in XRF analysis. Anal. Chem. 86, 6858-6864. https://doi.org/10.1021/ac5000619.
- Mantouvalou, I., Lachmann, T., Singh, S.P., Vogel-Mikuš, K., Kanngießer, B., (2017). Advanced Absorption Correction for 3D Elemental Images Applied to the Analysis of Pearl Millet Seeds Obtained with a Laboratory Confocal Micro X-ray Fluorescence Spectrometer. Analytical Chemistry, 89, 5453–5460. https://doi.org/10.1021/acs.analchem.7b00373.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Atom ve Molekül Fiziği
Bölüm
Araştırma Makalesi
Erken Görünüm Tarihi
25 Haziran 2025
Yayımlanma Tarihi
27 Haziran 2025
Gönderilme Tarihi
2 Şubat 2025
Kabul Tarihi
8 Mayıs 2025
Yayımlandığı Sayı
Yıl 2025 Cilt: 4 Sayı: 1