Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method
Öz
Aim: In order to evaluate the performance of the clinical laboratories, a quality measurement method, The Six-Sigma Methodology, is used. We aimed to evaluate the analytical performance of our clinical laboratory by using the internal and external quality control data of 28 analytes, and by calculating their process sigma values.
Methods: Sigma values of 28 analytes of our laboratory were determined from coefficient of variation (CV %) and bias for 3 subsequent months from December 2018 to January 2019. If the sigma values are >6, between 3 and 6, and <3, they are classified as »world-class«, »good« or »un-acceptable«, respectively.
Results: 6 (21%) analytes; T Protein, Creatinin, Ca, Na, Cl, HbA1c; provided <3 sigma value, 1 (04%) analyte; lipase; provided between 3-6 value and 11 (39%) analytes; amylase, GGT, ALT, LDH, CRP, Lactate, BUN, Direct Bil., T Bil., CK and CK-MB; provided > 6 sigma value for both IQC1 and IQC2 levels for three consecutive months, respectively.
Conclusions: In terms of Six-Sigma Metrics; our results were generally found as world-class or good. An appropriate quality control scheduling should be carried out for each test by using Six-Sigma Methodology in all clinical chemistry laboratories.
Anahtar Kelimeler
Kaynakça
- 1. Levey S, Jennings E. The use of control charts in the clinical laboratory. American Journal of Clinical Pathology. 1950;20(11_ts):1059-66.
- 2. Derleme Ç. Laboratuvar tıbbında altı-sigma kalite yönetimi. Türk Biyokimya Dergisi [Turkish Journal of Biochemistry-Turk J Biochem]. 2005;30(4):27.
- 3. Westgard JO. Six sigma quality design and control: Westgard QC, Incorporated; 2006.
- 4. Pande N. Cavanagh, The Six Sigma Way. McGraw Hill; 2000.
- 5. Verma M, Dahiya K, Ghalaut VS, Dhupper V. Assessment of quality control system by sigma metrics and quality goal index ratio: A roadmap towards preparation for NABL. World journal of methodology. 2018;8(3):44.
- 6. Litten J, Lynne N, Johnson K, Shih J. Evaluation of technopath controls on the architect family of instruments. Clin Chem Lab Med. 2015;53:S1-S1450.
- 7. Ercan M, BogdaycIoğlu N, Akbulut E, Oğuz E, Topçuoğlu C, YIlmaz F. ASSESSMENT OF THE ANALYTIC PERFORMANCE FOR IMMUNASSAY TESTS WITH SIX SIGMA METHODOLOGY: T425. Clinical Chemistry and Laboratory Medicine. 2015;53.
- 8. Nanda SK, Ray L. Quantitative application of sigma metrics in medical biochemistry. Journal of clinical and diagnostic research: JCDR. 2013;7(12):2689.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
30 Ocak 2021
Gönderilme Tarihi
18 Temmuz 2020
Kabul Tarihi
25 Kasım 2020
Yayımlandığı Sayı
Yıl 2021 Cilt: 11 Sayı: 1
APA
Katar, M., Deveci, K., & Özmen, Z. C. (2021). Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method. Journal of Contemporary Medicine, 11(1), 34-40. https://doi.org/10.16899/jcm.770304
AMA
1.Katar M, Deveci K, Özmen ZC. Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method. Journal of Contemporary Medicine. 2021;11(1):34-40. doi:10.16899/jcm.770304
Chicago
Katar, Muzaffer, Köksal Deveci, ve Zeliha Cansel Özmen. 2021. “Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method”. Journal of Contemporary Medicine 11 (1): 34-40. https://doi.org/10.16899/jcm.770304.
EndNote
Katar M, Deveci K, Özmen ZC (01 Ocak 2021) Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method. Journal of Contemporary Medicine 11 1 34–40.
IEEE
[1]M. Katar, K. Deveci, ve Z. C. Özmen, “Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method”, Journal of Contemporary Medicine, c. 11, sy 1, ss. 34–40, Oca. 2021, doi: 10.16899/jcm.770304.
ISNAD
Katar, Muzaffer - Deveci, Köksal - Özmen, Zeliha Cansel. “Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method”. Journal of Contemporary Medicine 11/1 (01 Ocak 2021): 34-40. https://doi.org/10.16899/jcm.770304.
JAMA
1.Katar M, Deveci K, Özmen ZC. Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method. Journal of Contemporary Medicine. 2021;11:34–40.
MLA
Katar, Muzaffer, vd. “Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method”. Journal of Contemporary Medicine, c. 11, sy 1, Ocak 2021, ss. 34-40, doi:10.16899/jcm.770304.
Vancouver
1.Muzaffer Katar, Köksal Deveci, Zeliha Cansel Özmen. Evaluation of The Total Quality Performance of Our Clinical Laboratory With Six-Sigma Method. Journal of Contemporary Medicine. 01 Ocak 2021;11(1):34-40. doi:10.16899/jcm.770304