Olgu Sunumu

Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report

Cilt: 10 Sayı: 2 1 Nisan 2019
PDF İndir
EN

Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report

Öz

Introduction: The pseudo-tumor cerebri (PTC) is defined as the idiopathic or benign intracranial hypertension (IH), complaints of which cannot be explained in a different way. PTC is an exclusion diagnosis, in which the neuroophtalmopathology of IH cannot be determined. The patients with PTC may have complaints such as headache, nausea, vomiting, temporary blurred vision, and mild-level vision loss or unilateral or bilateral abducens nerve paralysis may develop. The radiological examination of patients yields normal results. In case that IH develops due to any reason, the enlargement is seen in optic nerve sheath diameter (ONSD) in the acute period.

Case reports: 14 year-old patient, who has been diagnosed for PTC in our unit, optic nerve sheath diameter (ONSD) measurement and follow-up of pressure change of whom have been performed by using ultrasonography (USG) method, is presented in order to discuss the contribution of this non-invasive method to diagnosis, treatment, and observation processes.

Conclusion: USG and ONSD measurement in PTC cases may be effective and reliable monitoring method as much as invasive methods.

Anahtar Kelimeler

Kaynakça

  1. 1. Bekerman I, Sigal T, Kimiagar I, Almer ZE, Vaiman M. Diagnostic value of the optic nerve sheath diameter in pseudotumor cerebri. Journal of Clinical Neuroscience 2016; 30: 106-9.
  2. 2. Salahuddin N, Mohamed A, Alharbi N, Ansari H, Khaled JZ, Marashly Q, et al. The incidence of increased ICP in ICU patients with non-traumatic coma as diagnosed by ONSD and CT: a prospective cohort study. BMC Anesthesiol. 2016; 16: 106.
  3. 3. Friedmann DI, Jacobson DM. Diagnosis criteria for idiopathic intracranial hypertension. Neurology 2002; 59(95): 1492-5.
  4. 4. Lochner P, Nardone R, Tezzeon F, Coppo L. Optic Nerve Sonography to Monitor Treatment Efficacy in Idiopathic Intracranial Hypertension: A Case Report. Journal of Neuroimaging 2013; 23: 533-4.
  5. 5. Singleton J, Dagan A, Edlow JA, Hoffmann B. Real-time optic nerve sheath diameter reduction measured with bedside ultrasound after therapeutic lumbar puncture in a patient with idiopathic intracranial hypertension. American Journal of Emergency Medicine 2015; 33: 860.e5-7.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Olgu Sunumu

Yazarlar

Hayri Levent Yılmaz Bu kişi benim

Seyda Beğen Doğankoc Bu kişi benim

Sinem Sarı Gokay Bu kişi benim

Mihriban Ozlem Herguner Bu kişi benim

Yayımlanma Tarihi

1 Nisan 2019

Gönderilme Tarihi

8 Eylül 2018

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2019 Cilt: 10 Sayı: 2

Kaynak Göster

APA
Talu Kendir, O., Yılmaz, H. L., Doğankoc, S. B., Bilen, S., Sarı Gokay, S., & Herguner, M. O. (2019). Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports, 10(2), 58-60. https://doi.org/10.33706/jemcr.551140
AMA
1.Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports. 2019;10(2):58-60. doi:10.33706/jemcr.551140
Chicago
Talu Kendir, Ozlem, Hayri Levent Yılmaz, Seyda Beğen Doğankoc, Sevcan Bilen, Sinem Sarı Gokay, ve Mihriban Ozlem Herguner. 2019. “Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report”. Journal of Emergency Medicine Case Reports 10 (2): 58-60. https://doi.org/10.33706/jemcr.551140.
EndNote
Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO (01 Nisan 2019) Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports 10 2 58–60.
IEEE
[1]O. Talu Kendir, H. L. Yılmaz, S. B. Doğankoc, S. Bilen, S. Sarı Gokay, ve M. O. Herguner, “Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report”, Journal of Emergency Medicine Case Reports, c. 10, sy 2, ss. 58–60, Nis. 2019, doi: 10.33706/jemcr.551140.
ISNAD
Talu Kendir, Ozlem - Yılmaz, Hayri Levent - Doğankoc, Seyda Beğen - Bilen, Sevcan - Sarı Gokay, Sinem - Herguner, Mihriban Ozlem. “Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report”. Journal of Emergency Medicine Case Reports 10/2 (01 Nisan 2019): 58-60. https://doi.org/10.33706/jemcr.551140.
JAMA
1.Talu Kendir O, Yılmaz HL, Doğankoc SB, Bilen S, Sarı Gokay S, Herguner MO. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports. 2019;10:58–60.
MLA
Talu Kendir, Ozlem, vd. “Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report”. Journal of Emergency Medicine Case Reports, c. 10, sy 2, Nisan 2019, ss. 58-60, doi:10.33706/jemcr.551140.
Vancouver
1.Ozlem Talu Kendir, Hayri Levent Yılmaz, Seyda Beğen Doğankoc, Sevcan Bilen, Sinem Sarı Gokay, Mihriban Ozlem Herguner. Measuring the optic nerve sheath diameter by using ultrasonography in diagnosis and follow-up of pseudo-tumor cerebri: A case report. Journal of Emergency Medicine Case Reports. 01 Nisan 2019;10(2):58-60. doi:10.33706/jemcr.551140