BibTex RIS Kaynak Göster

Yabancı Cisime Bağlı Gelişen Brakiyal A-V Fistül: Olgu Sunumu

Yıl 2013, Cilt: 4 Sayı: 4, 151 - 153, 01.10.2013

Öz

Arteriovenous fistulas are one of the complications of penetrating extremity traumas. We present a brachial A-V fistula due to a conservatively treated penetrating foreign body on the left arm. Fistulas can be easily diagnosed after their occurrence. Efforts for preventing this complication are important. The risk of vascular injury has to be eliminated in penetrating injuries near to the localisation of major vessels. Duplex ultrasound and tomographic angiography are reasonable imaging methods for the emergency physicians in the diagnosis of vascular injury.

Kaynakça

  • Dry LR, Conn JR, Chavez CM, Hardy JD. Arteriovenous fistula: An analysis of fifty eight cases. Am Surg 1972; 38: 154-60.
  • Patman RD, Paulos E, Shires GT. The management of cilivian arterial in- juries. Surg Gynecol Obstet 1964; 118: 725-8.
  • Rich NM, Hobson RW II, Collins GJ. Traumatic arteriovenous fistulas and false aneurysms. A review of 558 lesions. Surgery 1976; 78: 817-21.
  • Tran HS, Burrows BJ, Zang WA, Han DC. Brachial arteriovenous fistula as a complication of placement of a peripherally inserted central venous cat- heter: a case report and review of the literature. Am Surg 2006; 72: 833-6.
  • Lebreton G, Uzel AP, Celerien J, Roques F, Deneuville M. Popliteal arte- riovenous fistula due to a gunshot injury. Ann Vasc Surg 2010; 24: 952. [CrossRef]

Brachial A-V Fistula Due to a Foreign Body: a Case Report

Yıl 2013, Cilt: 4 Sayı: 4, 151 - 153, 01.10.2013

Öz

Arteriovenous fistulas are one of the complications of penetrating extremity traumas. We present a brachial A-V fistula due to a conservatively treated penetrating foreign body on the left arm. Fistulas can be easily diagnosed after their occurrence. Efforts for preventing this complication are important. The risk of vascular injury has to be eliminated in penetrating injuries near to the localisation of major vessels. Duplex ultrasound and tomographic angiography are reasonable imaging methods for the emergency physicians in the diagnosis of vascular injury

Kaynakça

  • Dry LR, Conn JR, Chavez CM, Hardy JD. Arteriovenous fistula: An analysis of fifty eight cases. Am Surg 1972; 38: 154-60.
  • Patman RD, Paulos E, Shires GT. The management of cilivian arterial in- juries. Surg Gynecol Obstet 1964; 118: 725-8.
  • Rich NM, Hobson RW II, Collins GJ. Traumatic arteriovenous fistulas and false aneurysms. A review of 558 lesions. Surgery 1976; 78: 817-21.
  • Tran HS, Burrows BJ, Zang WA, Han DC. Brachial arteriovenous fistula as a complication of placement of a peripherally inserted central venous cat- heter: a case report and review of the literature. Am Surg 2006; 72: 833-6.
  • Lebreton G, Uzel AP, Celerien J, Roques F, Deneuville M. Popliteal arte- riovenous fistula due to a gunshot injury. Ann Vasc Surg 2010; 24: 952. [CrossRef]
Toplam 5 adet kaynakça vardır.

Ayrıntılar

Diğer ID JA27ZP88PP
Bölüm Case Report
Yazarlar

Mehmet Koşargelir Bu kişi benim

Mehmet Özgür Erdoğan Bu kişi benim

İsmail Tayfur Bu kişi benim

Şahin Çolak Bu kişi benim

Burcu Genç Yavuz Bu kişi benim

Yayımlanma Tarihi 1 Ekim 2013
Gönderilme Tarihi 1 Ekim 2013
Yayımlandığı Sayı Yıl 2013 Cilt: 4 Sayı: 4

Kaynak Göster

APA Koşargelir, M., Erdoğan, M. Ö., Tayfur, İ., Çolak, Ş., vd. (2013). Brachial A-V Fistula Due to a Foreign Body: a Case Report. Journal of Emergency Medicine Case Reports, 4(4), 151-153.
AMA Koşargelir M, Erdoğan MÖ, Tayfur İ, Çolak Ş, Yavuz BG. Brachial A-V Fistula Due to a Foreign Body: a Case Report. Journal of Emergency Medicine Case Reports. Ekim 2013;4(4):151-153.
Chicago Koşargelir, Mehmet, Mehmet Özgür Erdoğan, İsmail Tayfur, Şahin Çolak, ve Burcu Genç Yavuz. “Brachial A-V Fistula Due to a Foreign Body: a Case Report”. Journal of Emergency Medicine Case Reports 4, sy. 4 (Ekim 2013): 151-53.
EndNote Koşargelir M, Erdoğan MÖ, Tayfur İ, Çolak Ş, Yavuz BG (01 Ekim 2013) Brachial A-V Fistula Due to a Foreign Body: a Case Report. Journal of Emergency Medicine Case Reports 4 4 151–153.
IEEE M. Koşargelir, M. Ö. Erdoğan, İ. Tayfur, Ş. Çolak, ve B. G. Yavuz, “Brachial A-V Fistula Due to a Foreign Body: a Case Report”, Journal of Emergency Medicine Case Reports, c. 4, sy. 4, ss. 151–153, 2013.
ISNAD Koşargelir, Mehmet vd. “Brachial A-V Fistula Due to a Foreign Body: a Case Report”. Journal of Emergency Medicine Case Reports 4/4 (Ekim 2013), 151-153.
JAMA Koşargelir M, Erdoğan MÖ, Tayfur İ, Çolak Ş, Yavuz BG. Brachial A-V Fistula Due to a Foreign Body: a Case Report. Journal of Emergency Medicine Case Reports. 2013;4:151–153.
MLA Koşargelir, Mehmet vd. “Brachial A-V Fistula Due to a Foreign Body: a Case Report”. Journal of Emergency Medicine Case Reports, c. 4, sy. 4, 2013, ss. 151-3.
Vancouver Koşargelir M, Erdoğan MÖ, Tayfur İ, Çolak Ş, Yavuz BG. Brachial A-V Fistula Due to a Foreign Body: a Case Report. Journal of Emergency Medicine Case Reports. 2013;4(4):151-3.