Rapor

THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION

Cilt: 2 Sayı: 3 30 Aralık 2014
  • Dragos - Laurentiu Popa
  • Alina Duta
  • Allma – Roxana Pıtru
PDF İndir
EN TR

THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION

Öz

In order to understand the problems, which occur during the implanting and the prosthetics process, it was highly important to be acquainted with the anatomy of the human skeleton, the way these components are working together to achieve a normal functionality. In this respect CAD parametric software has been used as it allows to define models with a high degree of difficulty. First, the main bone components were defined by using CT images. These images were then transferred to AutoCAD where the outer and inner contours of the bone were approximate to polygonal lines composed by many segments. These contours were transferred to SolidWorks where, step by step, and section by section, the virtual model of the chewing system has been defined. Using the direct measurement method the virtual metallic components used during implant process were generated. The virtual models were then exported to a software for kinematical and FEA simulation. Using similar initial parameters for each case studied (as total force and torque) there were obtained dynamic maps of stress, strain and displacement. Furhermore the results have been analyzed and compared, leading subsequently to the main extracted conclusions

Anahtar Kelimeler

Kaynakça

  1. Baciu C., 1986. Musculoskeletal surgery and prosthesis, in Romanian, Ed. medicala, Bucureşti, 399- 40
  2. Buciu G., Popa D.L., Grecu D., Niculescu D., Nemes R., 20 Virtual comparative study on the use of nails at the fixation of tibial fractures using finite element method, The 4th International Conference Advanced Composite Materials Engineering, Lux Libris Publishing House, Brasov, Romania, 381-386. Buciu G., Popa D.L., Grecu D., Niculescu D., 2012.
  3. Nemes R., Comparative analysis of the three new designs of tibial nails which eliminate the use of orthopedic screws, The 4th International Conference Advanced Composite Materials Engineering, Lux Libris Publishing House, Brasov, Romania, 387-392. Buciu G., Grecu D., Niculescu D., Chiutu L, Stoica M., Popa D., 2013. Studies about Virtual Behavior of Tibia
  4. Fractures and Nails During the Fixation, Journal of Industrial Design and Engineering Graphics, vol.8, issue no.2. Buser, D., Cho, J.-Y., Yeo, A.B.K., 2007. Surgical Manual of Implant Dentistry: Step-By-Step Procedures, ISBN- 13: 978-0-86715-379-8, ISBN-10: 0-86715-379-2,
  5. Quintessence Publishing Co, Inc, Illinois. Ciunel, S., Popa, D.L., Dumitru, N., 2013. Studies about
  6. Movement Biofidelity of a Dummy Neck Used in an Impact Testing Device, Applied Mechanics and Materials Vol. 371, 539-543, Online available since 2013/Aug/30 at www.scientific.net, Publications, www.scientific.net/AMM.371.539. Trans Tech doi:4028/ Switzerland
  7. C. Drago, T. Peterson, 2010. Implant Laboratory
  8. Procedures: A Step-by-Step Guide, Blackwell Publishing, ISBN-13: 978-0-8138-2301-0.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Rapor

Yazarlar

Dragos - Laurentiu Popa Bu kişi benim

Alina Duta Bu kişi benim

Allma – Roxana Pıtru Bu kişi benim

Yayımlanma Tarihi

30 Aralık 2014

Gönderilme Tarihi

2 Ocak 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2014 Cilt: 2 Sayı: 3

Kaynak Göster

APA
Popa, D.- L., Duta, A., & Pıtru, A. – R. (2014). THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION. Mühendislik Bilimleri ve Tasarım Dergisi, 2(3), 273-281. https://izlik.org/JA28TT55EN
AMA
1.Popa D L, Duta A, Pıtru A – R. THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION. MBTD. 2014;2(3):273-281. https://izlik.org/JA28TT55EN
Chicago
Popa, Dragos - Laurentiu, Alina Duta, ve Allma – Roxana Pıtru. 2014. “THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION”. Mühendislik Bilimleri ve Tasarım Dergisi 2 (3): 273-81. https://izlik.org/JA28TT55EN.
EndNote
Popa D- L, Duta A, Pıtru A – R (01 Aralık 2014) THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION. Mühendislik Bilimleri ve Tasarım Dergisi 2 3 273–281.
IEEE
[1]D.- L. Popa, A. Duta, ve A. – R. Pıtru, “THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION”, MBTD, c. 2, sy 3, ss. 273–281, Ara. 2014, [çevrimiçi]. Erişim adresi: https://izlik.org/JA28TT55EN
ISNAD
Popa, Dragos - Laurentiu - Duta, Alina - Pıtru, Allma – Roxana. “THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION”. Mühendislik Bilimleri ve Tasarım Dergisi 2/3 (01 Aralık 2014): 273-281. https://izlik.org/JA28TT55EN.
JAMA
1.Popa D- L, Duta A, Pıtru A – R. THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION. MBTD. 2014;2:273–281.
MLA
Popa, Dragos - Laurentiu, vd. “THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION”. Mühendislik Bilimleri ve Tasarım Dergisi, c. 2, sy 3, Aralık 2014, ss. 273-81, https://izlik.org/JA28TT55EN.
Vancouver
1.Dragos - Laurentiu Popa, Alina Duta, Allma – Roxana Pıtru. THE MODELING OF SOME TYPES OF IMPLANTS AND PROSTHESES USED FOR OSTEOINTEGRATION. MBTD [Internet]. 01 Aralık 2014;2(3):273-81. Erişim adresi: https://izlik.org/JA28TT55EN