Objective: Our aim in this study is to investigate the relationship between mortality and morbidity of phosphorylcholine coated oxygenator circuit used in heart-lung machine in congenital open heart surgery operations.
Materials and Methods: The study was conducted in Dr. Sami Ulus Child Diseases Training and Research Hospital Cardiovascular Surgery Clinic between 2008-2009. 30 congenital heart patients were included. The patients were divided into 2 groups of 15 people. In one of the groups, a phosphorylcholine coated oxygenator circuit was used in the heart lung machine (Group P). In the other group, a standard oxygenator circuit was used (Group C).Congenital heart surgery was performed for 19 Ventricular Septal Defects (VSD), 5 Secundum Atrial Septal Defects (ASD), 3 Primum ASD, 2 Mitral insufficiency and 1 Discret subaortic membrane.
Extubation times, intensive care and discharge times, 24-hour drainage follow-up, inotropic drug use, blood and fresh frozen plasma (FFP) transfusion amount, aspartate aminotransferase, alanine aminotransferase, creatine phosphokinase-MB, urea, blood urea nitrogen, creatinine, white cell number of platelets, lactate dehydrogenase, albumin, total protein, C-reactive protein, prothrombin time, partial thromboplastin time, fibrinogen, D-dimer, C5a and elastase levels were compared perioperatively.
Results: In the study, it was determined that the discharge time was shorter in Group P. It was found that the increase in d-dimer values with fibrinogen was less in Group P. These were found to be statistically significant (p <0.05). There was no significant difference between groups in other parameters (p> 0.05). There was no mortality in either group.
Conclusion: In this study, phosphorylcholine-coated oxygenator did not significantly reduce the inflammatory response during cardiopulmonary by-pass (CPB). There was no difference between the two groups in terms of morbitidity and mortality.However, the fact that fibrinogen values, which are the acute phase reactants, are lower than the control group and the increase in d-dimer values remain limited may be important in terms of hemocompatibility of the phosphorylcholine coated circuit.
Phosphorylcholine coated oxygenator congenital heart surgery cardiopulmonary bypass inflammation
YOK
Birincil Dil | İngilizce |
---|---|
Konular | Sağlık Kurumları Yönetimi |
Bölüm | Orijinal Makale |
Yazarlar | |
Proje Numarası | YOK |
Yayımlanma Tarihi | 28 Mart 2021 |
Yayımlandığı Sayı | Yıl 2021 Cilt: 4 Sayı: 2 |
Üniversitelerarası Kurul (ÜAK) Eşdeğerliği: Ulakbim TR Dizin'de olan dergilerde yayımlanan makale [10 PUAN] ve 1a, b, c hariç uluslararası indekslerde (1d) olan dergilerde yayımlanan makale [5 PUAN]
Dahil olduğumuz İndeksler (Dizinler) ve Platformlar sayfanın en altındadır.
Not: Dergimiz WOS indeksli değildir ve bu nedenle Q olarak sınıflandırılmamıştır.
Yüksek Öğretim Kurumu (YÖK) kriterlerine göre yağmacı/şüpheli dergiler hakkındaki kararları ile yazar aydınlatma metni ve dergi ücretlendirme politikasını tarayıcınızdan indirebilirsiniz. https://dergipark.org.tr/tr/journal/2316/file/4905/show
Dergi Dizin ve Platformları
Dizinler; ULAKBİM TR Dizin, Index Copernicus, ICI World of Journals, DOAJ, Directory of Research Journals Indexing (DRJI), General Impact Factor, ASOS Index, WorldCat (OCLC), MIAR, EuroPub, OpenAIRE, Türkiye Citation Index, Türk Medline Index, InfoBase Index, Scilit, vs.
Platformlar; Google Scholar, CrossRef (DOI), ResearchBib, Open Access, COPE, ICMJE, NCBI, ORCID, Creative Commons vs.