With this study, a study had been carried out to meet part of the total electricity need in a site consisting of 4 houses by the photovoltaic-battery (PV-BT) system. Partial energy to be covered by the PV-BT system was aimed to be distributed equally among these 4 houses. Standard deviation method was used for fair distribution. Standard deviation calculations were made with the conditional flow algorithm (CFA), random algorithm (RA) and excel solver (ES). Optimization studies were carried out according to this standard deviation value. CFA and particle swarm optimization (PSO) algorithms were used for optimization. At the end of the study, the minimum standard deviation value was calculated as 0.219779. Fair usage percentages were calculated as 1.1061%, 9.1814%, 32.3474% and 57.3650% for the minimum standard deviation for each house, respectively. According to the minimum standard deviation value, the optimum result was obtained with CFA.
Fair usage Optimization Particle swarm optimization Renewable energy Standard deviation
Birincil Dil | İngilizce |
---|---|
Bölüm | Araştırma Makaleleri |
Yazarlar | |
Yayımlanma Tarihi | 30 Haziran 2022 |
Gönderilme Tarihi | 30 Aralık 2021 |
Kabul Tarihi | 12 Mart 2022 |
Yayımlandığı Sayı | Yıl 2022 Cilt: 5 Sayı: 1 |