Araştırma Makalesi

Degradation of Oxytetracycline and Chlortetracycline by Fenton Process

Cilt: 13 Sayı: 1 1 Mart 2023
PDF İndir
EN

Degradation of Oxytetracycline and Chlortetracycline by Fenton Process

Öz

In this study, degradation of oxytetracycline (OTC) and chlortetracycline (CTC) was investigated by Fenton process. In experimental studies conducted for this purpose, different values of pH, Fe2+ concentration, H2O2 concentration and reaction time were tested as important parameters for the Fenton process and optimum conditions for OTC and CTC removal were determined. For both antibiotics, the optimum values of the parameters in the Fenton process were the same, and these values were found to be 3 for pH, 20 mg/L for Fe2+ concentration, 25 mg/L for H2O2 concentration, 5 min for reaction time. Under these optimum conditions, OTC degradation was 100%, CTC degradation was 99.68%, chemical oxygen demand (COD) removal efficiency for oxytetracycline (O-COD) was 89.6%, COD removal efficiency for chlortetracycline (C-COD) was 88.5%. These results show that the Fenton process is an effective method that can be used for OTC and CTC degradation.

Anahtar Kelimeler

Kaynakça

  1. Alalm, M. G., Tawfik, A. & Ookawara, S. (2015). Degradation of four pharmaceuticals by solar photo-Fenton process: kinetics and costs estimation. Journal of Environmental Chemical Engineering, 3(1), 46-51.
  2. Aydın, E., Şahin, M., Taşkan, E., Hasar, H. & Erdem, M. (2016). Chlortetracycline removal by using hydrogen based membrane biofilm reactor. Journal of Hazardous Materials, 320, 88-95.
  3. Cahino, A. M., de Andrade, M. M. A., de Araújo, E. S., Silva, E. L., Cunha, C. D. O. & Rocha, E. M. R. (2018). Degradation of tetracycline by solar photo‐Fenton: Optimization and application in pilot photoreactor. Environmental Quality Management, 28(1), 101-106.
  4. Çelik, A., Casey, E. ve Hasar, H. (2018). Degradation of oxytetracycline under autotrophic nitrifying conditions in a membrane aerated biofilm reactor and community fingerprinting. Journal of Hazardous Materials, 356, 26-33.
  5. De la Cruz, N., Giménez, J., Esplugas, S., Grandjean, D., De Alencastro, L. F. & Pulgarin, C. (2012). Degradation of 32 emergent contaminants by UV and neutral photo-fenton in domestic wastewater effluent previously treated by activated sludge. Water Research, 46(6), 1947-1957.
  6. Daghrir, R. & Drogui, P. (2013). Tetracycline antibiotics in the environment: a review. Environmental Chemistry Letter, 11(3), 209-227.
  7. Dalgic, G., Turkdogan, I. F., Yetilmezsoy, K. & Kocak, E. (2017). Treatment of real paracetamol wastewater by Fenton process. Chemical Industry and Chemical Engineering Quarterly, 23(2), 177-186.
  8. Elmolla, E. S. & Chaudhuri, M. (2009). Degradation of the antibiotics amoxicillin, ampicillin and cloxacillin in aqueous solution by the photo-Fenton process. Journal of Hazardous Materials, 172, 1476-1481.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Çevre Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Mart 2023

Gönderilme Tarihi

5 Ağustos 2022

Kabul Tarihi

31 Ekim 2022

Yayımlandığı Sayı

Yıl 2023 Cilt: 13 Sayı: 1

Kaynak Göster

APA
Çelik, M., Aydın, E., Celik, A., & Gürtekin, E. (2023). Degradation of Oxytetracycline and Chlortetracycline by Fenton Process. Journal of the Institute of Science and Technology, 13(1), 192-199. https://doi.org/10.21597/jist.1157037
AMA
1.Çelik M, Aydın E, Celik A, Gürtekin E. Degradation of Oxytetracycline and Chlortetracycline by Fenton Process. Iğdır Üniv. Fen Bil Enst. Der. 2023;13(1):192-199. doi:10.21597/jist.1157037
Chicago
Çelik, Murat, Ekrem Aydın, Aytekin Celik, ve Engin Gürtekin. 2023. “Degradation of Oxytetracycline and Chlortetracycline by Fenton Process”. Journal of the Institute of Science and Technology 13 (1): 192-99. https://doi.org/10.21597/jist.1157037.
EndNote
Çelik M, Aydın E, Celik A, Gürtekin E (01 Mart 2023) Degradation of Oxytetracycline and Chlortetracycline by Fenton Process. Journal of the Institute of Science and Technology 13 1 192–199.
IEEE
[1]M. Çelik, E. Aydın, A. Celik, ve E. Gürtekin, “Degradation of Oxytetracycline and Chlortetracycline by Fenton Process”, Iğdır Üniv. Fen Bil Enst. Der., c. 13, sy 1, ss. 192–199, Mar. 2023, doi: 10.21597/jist.1157037.
ISNAD
Çelik, Murat - Aydın, Ekrem - Celik, Aytekin - Gürtekin, Engin. “Degradation of Oxytetracycline and Chlortetracycline by Fenton Process”. Journal of the Institute of Science and Technology 13/1 (01 Mart 2023): 192-199. https://doi.org/10.21597/jist.1157037.
JAMA
1.Çelik M, Aydın E, Celik A, Gürtekin E. Degradation of Oxytetracycline and Chlortetracycline by Fenton Process. Iğdır Üniv. Fen Bil Enst. Der. 2023;13:192–199.
MLA
Çelik, Murat, vd. “Degradation of Oxytetracycline and Chlortetracycline by Fenton Process”. Journal of the Institute of Science and Technology, c. 13, sy 1, Mart 2023, ss. 192-9, doi:10.21597/jist.1157037.
Vancouver
1.Murat Çelik, Ekrem Aydın, Aytekin Celik, Engin Gürtekin. Degradation of Oxytetracycline and Chlortetracycline by Fenton Process. Iğdır Üniv. Fen Bil Enst. Der. 01 Mart 2023;13(1):192-9. doi:10.21597/jist.1157037

Cited By