Advanced oxidation processes (AOPs) such as Fenton process have been used successfully
treatment of industrial wastewater containing toxic and non-biodegradable substances. In this study, treatability
of an industrial wastewater containing high organic matter has been investigated by fenton process. This type of
wastewater contained high chemical oxygen demand (COD) may be caused important environmental problems.
Optimal values of parameters such as the concentration of Fe+2 and H2O2, pH were investigated to increase the
removal of COD of a raw wastewater by Fenton process. The optimum conditions were decided to be: pH 4, the
dose of 10 g L-1 H2O2 and 1.61 g L-1 for Fe+2. Under these conditions, COD removal was 88%.
Fenton process advanced oxidation industrial wastewater treatment
Fenton prosesi gibi ileri oksidasyon prosesleri (İOP) biyolojik olarak ayrışamayan ve toksik madde içeren
endüstriyel atıksu arıtımında başarılı bir şekilde kullanılmaktadır. Bu çalışma kapsamında, yüksek organik madde
içeren endüstriyel bir atıksuyun Fenton prosesi ile arıtılabilirliği araştırılmıştır. Bu tip atıksular yüksek kimyasal
oksijen ihtiyaçları (KOİ) nedeniyle önemli çevresel problemlere sebep olabilirler. Fenton oksidasyon prosesi ile
KOİ giderim verimini arttırmak amacıyla; Fe+2, H2O2 konsantrasyonu ve pH parametrelerinin optimum değerleri
araştırılmıştır. Optimizasyon çalışmaları sonucunda pH, H2O2 ve Fe+2 dozu sırasıyla 4, 10 g L-1 ve 1.61 g L-1 olarak
belirlenmiştir. Bu şartlar altında KOİ giderim verimi %88 olarak bulunmuştur.
Fenton prosesi ileri oksidasyon endüstriyel atık su arıtımı