Araştırma Makalesi

The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time

Cilt: 1 Sayı: 1 17 Haziran 2019
  • Meryem Cansu Şahin *
  • İsmail Kaya
  • Nevin Aydın
  • İlker Deniz Cingöz
  • Hasan Emre Aydın
PDF İndir
EN TR

The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time

Öz

Our study is aiming retrospective survey of the corrosion resistence of above-stated silver and hydroxyapatite covered pedicle screws depending on routinely surgery used Ti and Ti-6Al-4V compounded pedicle screws. 32 pedicle screw coverings in different sizes removed after the revision surgery were separated into three groups (Ti-6Al-4V, Silver Covering and Hydroxyapatite Covering). Screws in every group were measured in order of diameter (mm) and severity (gram). The implanted residence times (day) of pedicle screws in patients were recorded by using patient records. According to the results, we observed that silver and hydroxyapatite covered pedicle screws and time have a correlation relation in a positive way. However, this situation is total opposite for Ti-6Al-4V pedicle screws. Any correlation relation in a positive way between severity difference and time wasn’t found in any pedicle screw group. Hydroxyapatite and silver can not be used unattended in the body because of their biomechanic resistance and various toxic features. When they are added on to the Titanium screws with different covering techniques, biocompatible and antibacterial surgical instruments are obtained. Our purpose is improving very image of hydroxyapatite and silver covering materials with succesful results we gained.

Anahtar Kelimeler

Kaynakça

  1. 1. Evis, Z., Çeşitli İyonlar Eklenmiş Nano-Hidroksiapatitler: Üretim Yöntemleri, İç Yapı, Mekanik ve Biyouyumluluk Özellikleri Yönlerinden İncelenmesi, Int. J. Eng. Res. Dev., 3, 55-61, 2011.
  2. 2. Boden SD, Schimandle JH. Biologic enhancement of spinal fusion. Spine ;20:113–23., 1999.
  3. 3. Hayashi K, Uenoyama K, Mashima T, et al. Remodeling of bone around hydroxyapatite and titanium in experimental osteoporosis. Biomaterials;15:11–6; 1994.
  4. 4. Barber JW, Boden SD, Ganey T, et al. Biomechanical study of lumbar pedicle screws: Does convergence affect axial pullout strength? J Spinal Disord;11:215–20; 1998.
  5. 5. Jansen JA, Waerden JPCM, Wolke JGC, et al. Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res;25:973–89; 1991.
  6. 6. Niinomi, M., Nakai, M., Titanium-based biomaterials for preventing stress shielding between implant devices and bone, International Journal of Biomaterials, 2011.
  7. 7. Damodaran, V. B., Bhatnagar, D., Leszczak, V., Popat, K. C., Titania nanostructures: a biomedical perspective, RSC Advances, 5, 37149-37171, 2015.
  8. 8. Yeniyol, S., Saf titanyum implant yüzeylerinin değişik yöntemlerle modifikasyonu, ve karakterizasyonu-in vitro çalışma, Doktora Tezi, İstanbul Üniversitesi Sağlık Bilimleri Enstitüsü, İstanbul 2006.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Cerrahi

Bölüm

Araştırma Makalesi

Yazarlar

Meryem Cansu Şahin * Bu kişi benim
0000-0002-5743-3734
Türkiye

İlker Deniz Cingöz Bu kişi benim
0000-0002-0452-7606
Türkiye

Hasan Emre Aydın Bu kişi benim
0000-0002-8932-1542
Türkiye

Yayımlanma Tarihi

17 Haziran 2019

Gönderilme Tarihi

12 Şubat 2020

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2019 Cilt: 1 Sayı: 1

Kaynak Göster

APA
Şahin, M. C., Kaya, İ., Aydın, N., Cingöz, İ. D., & Aydın, H. E. (2019). The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time. Journal of Medical Innovation and Technology, 1(1), 9-15. https://izlik.org/JA39AU89WW
AMA
1.Şahin MC, Kaya İ, Aydın N, Cingöz İD, Aydın HE. The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time. Journal of Medical Innovation and Technology. 2019;1(1):9-15. https://izlik.org/JA39AU89WW
Chicago
Şahin, Meryem Cansu, İsmail Kaya, Nevin Aydın, İlker Deniz Cingöz, ve Hasan Emre Aydın. 2019. “The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time”. Journal of Medical Innovation and Technology 1 (1): 9-15. https://izlik.org/JA39AU89WW.
EndNote
Şahin MC, Kaya İ, Aydın N, Cingöz İD, Aydın HE (01 Haziran 2019) The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time. Journal of Medical Innovation and Technology 1 1 9–15.
IEEE
[1]M. C. Şahin, İ. Kaya, N. Aydın, İ. D. Cingöz, ve H. E. Aydın, “The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time”, Journal of Medical Innovation and Technology, c. 1, sy 1, ss. 9–15, Haz. 2019, [çevrimiçi]. Erişim adresi: https://izlik.org/JA39AU89WW
ISNAD
Şahin, Meryem Cansu - Kaya, İsmail - Aydın, Nevin - Cingöz, İlker Deniz - Aydın, Hasan Emre. “The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time”. Journal of Medical Innovation and Technology 1/1 (01 Haziran 2019): 9-15. https://izlik.org/JA39AU89WW.
JAMA
1.Şahin MC, Kaya İ, Aydın N, Cingöz İD, Aydın HE. The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time. Journal of Medical Innovation and Technology. 2019;1:9–15.
MLA
Şahin, Meryem Cansu, vd. “The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time”. Journal of Medical Innovation and Technology, c. 1, sy 1, Haziran 2019, ss. 9-15, https://izlik.org/JA39AU89WW.
Vancouver
1.Meryem Cansu Şahin, İsmail Kaya, Nevin Aydın, İlker Deniz Cingöz, Hasan Emre Aydın. The Retrospective Survey of Corrosion Amount Inside The Tissue of Spinal Surgery Used Titanium Pedicle Screws in Time. Journal of Medical Innovation and Technology [Internet]. 01 Haziran 2019;1(1):9-15. Erişim adresi: https://izlik.org/JA39AU89WW