Araştırma Makalesi

Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities

Sayı: 20 1 Temmuz 2024
PDF İndir
EN

Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities

Öz

A2-Slab discontinuities are one of the irregularities in the plan defined in the Turkish Building Earthquake Code-2018 (TBEC-2018). This irregularity may occur due to reasons such as keeping the staircase section wide in buildings, leaving wide gallery spaces especially in workplaces and leaving large elevator shafts in buildings with small floor areas. Local openings in the slabs prevent the rigid diaphragm behaviour of the slabs by reducing the stiffness. This situation makes it difficult to safely transfer horizontal loads in the structural system. Besides, lateral translations increase due to slab discontinuities. Therefore, slab discontinuities are limited in the earthquake code. In addition to slab openings, sudden decreases in the plane stiffness and strength of the slabs also cause A2 irregularity. In this study, structural safety system of an existing reinforced concrete building having slab discontinuity irregularity in plan is investigated. Incremental pushover analysis procedure that is one of the non-linear analysis methods is utilized by considering the information of concrete, reinforcement steel and local soil class of the existing building. Afterwards, structural performance analysis is performed again by strengthening the existing building with column jacketing and reinforced concrete shear walls. Protastructure 2022 program has been used in the analyses performed in the computer environment. Damage situations of the structural members have been determined according to the analysis results obtained from the existing and strengthened buildings. Finally, the results have been compared and evaluations have been carried out.

Anahtar Kelimeler

Kaynakça

  1. [1] Türkiye bina deprem yönetmeliği (2018). Afet ve Acil Durum Yönetimi Başkanlığı, Ankara.
  2. [2] Türkiye deprem tehlike haritası (2018). Afet ve Acil Durum Yönetimi Başkanlığı, Ankara.
  3. [3] Sadat Z., Arslan A.S. (2022). Betonarme yapılarda burulma düzensizliğinin önlenmesinde genetik algoritma yaklaşımı. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, 37(3), 1469-1482.
  4. [4] Özmen G., Girgin K., Durgun Y. (2014). Torsional irregularity in multi-story structures. International Journal of Advanced Structural Engineering, 6, 121-131, 2014.
  5. [5] Gökalp E., Bağcı M. (2009). A2 düzensizliği bulunan betonarme bir binanın, mod birleştirme yöntemi ile deprem performansının belirlenmesi. Yapı Teknolojileri Elektronik Dergisi, 5(1), 37-48.
  6. [6] Yön B., Öncü M.E., Sayın, E. (2010). Binalardaki burulma düzensizliğinin farklı zemin sınıflarına göre değerlendirilmesi. Celal Bayar Üniversitesi Fen Bilimleri Dergisi, 6(1), 19-32.
  7. [7] Erdem R.T., Karal K. (2022). Performance evaluation and strengthening of reinforced concrete buildings. Revista de la Construcción, 21(1), ss. 53-68.
  8. [8] Golghate K,. Vijay B., Amit S. (2013). Pushover analysis of 4 storey’s reinforced concrete building. International Journal of Latest Trends in Engineering and Technology, 2(3), 80-84.

Ayrıntılar

Birincil Dil

Türkçe

Konular

Betonarme Yapılar

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Temmuz 2024

Gönderilme Tarihi

28 Ağustos 2023

Kabul Tarihi

1 Temmuz 2024

Yayımlandığı Sayı

Yıl 2024 Sayı: 20

Kaynak Göster

APA
Altınay, M. K., & Erdem, R. T. (2024). Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities. Journal of New Results in Engineering and Natural Sciences, 20, 1-18. https://izlik.org/JA25PG64JL
AMA
1.Altınay MK, Erdem RT. Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities. JRENS. 2024;(20):1-18. https://izlik.org/JA25PG64JL
Chicago
Altınay, Mehmet Kemal, ve R. Tuğrul Erdem. 2024. “Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities”. Journal of New Results in Engineering and Natural Sciences, sy 20: 1-18. https://izlik.org/JA25PG64JL.
EndNote
Altınay MK, Erdem RT (01 Temmuz 2024) Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities. Journal of New Results in Engineering and Natural Sciences 20 1–18.
IEEE
[1]M. K. Altınay ve R. T. Erdem, “Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities”, JRENS, sy 20, ss. 1–18, Tem. 2024, [çevrimiçi]. Erişim adresi: https://izlik.org/JA25PG64JL
ISNAD
Altınay, Mehmet Kemal - Erdem, R. Tuğrul. “Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities”. Journal of New Results in Engineering and Natural Sciences. 20 (01 Temmuz 2024): 1-18. https://izlik.org/JA25PG64JL.
JAMA
1.Altınay MK, Erdem RT. Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities. JRENS. 2024;:1–18.
MLA
Altınay, Mehmet Kemal, ve R. Tuğrul Erdem. “Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities”. Journal of New Results in Engineering and Natural Sciences, sy 20, Temmuz 2024, ss. 1-18, https://izlik.org/JA25PG64JL.
Vancouver
1.Mehmet Kemal Altınay, R. Tuğrul Erdem. Analysis and Strengthening of an Existing Reinforced Concrete Building Having Slab Discontinuities. JRENS [Internet]. 01 Temmuz 2024;(20):1-18. Erişim adresi: https://izlik.org/JA25PG64JL