Araştırma Makalesi

ELECTROCHEMICAL DETERMINATION OF THE INTERACTION BETWEEN ANTICANCER DRUG CAPECITABINE AND DNA BY CARBON PASTE ELECTRODE

Cilt: 4 Sayı: 1 31 Ocak 2020
PDF İndir
EN TR

ELECTROCHEMICAL DETERMINATION OF THE INTERACTION BETWEEN ANTICANCER DRUG CAPECITABINE AND DNA BY CARBON PASTE ELECTRODE

Abstract

In this study, the interaction of an anticancer drug, Capecitabine with DNA was investigated by electrochemical methods using carbon paste electrode (CPE). The interaction of Capecitabine with single-stranded Calf thymus DNA (ss DNA) and double-stranded Calf thymus DNA (ds DNA) at electrode surface, or in solution phase was investigated by monitoring the changes at the oxidation signal of guanin base of DNA measured by differential pulse voltammetry (DPV) technique. Impedimetric measurements were performed by electrochemical impedance spectroscopy technique that also confirmed that ds DNA was immobilized onto the electrode surface. The detection limit (DL) in the case of interaction of Capecitabine with dsDNA and ssDNA interaction was calculated and found to be 17.35µg/mL and 17.12µg/mL, respectively.

Keywords

Kaynakça

  1. ÖZSÖZ. M., ERDEM. A., KARA. P., KERMAN. K., ÖZKAN. D., Electrochemical biosensor for the detection of interaction between arsenic trioxide and DNA based on guanine signal, Electroanal., 15 (2002) 613- 619.
  2. WANG. J., Electrochemical DNA biosensors. Electroanalytical methods for biological materials, (2002) 27–41
  3. WANG. J., DNA electrochemical biosensors for environmental monitoring. A Review, Anal. Chim.Acta, 347 (1997) 1-9.
  4. ERDEM. A., A review: Nanomaterial-based electrochemical DNA sensing strategies, Talanta, 74 (2007) 318-325
  5. NAWAZ. H., RAUF. S., AKHTAR. K., KHALID. A.M., Electrochemical DNA biosensor for the study of ciprofloxacin–DNA interaction, Analytical Biochemistry, 354 (2006) 28–34.
  6. RAUF. S., GOODING. J.J, AKHTAR. K., GHAURI. M.A, RAHMAN. M., ANWAR. M.A., KHALID. A.M., Electrochemical approach of anticancer drugs–DNA interaction, Journal of Pharmaceutical and Biomedical Analysis, 37 (2005) 205–217.
  7. ERDEM. A., ÖZSÖZ. M., İnteraction of anticancer drug, Epirubicin with DNA, Anal. Chim. Acta, 437 (2001) 107-114
  8. WANG. J., RIVAS. G., FERNANDES. J. R., JIANG. M., PAZ. J.L.L., WAYMIRE. R., NIELSEN. T.W., GETTS. R.C., Adsorption and detection of DNA dendrimers at carbon electrodes, Electroanal., 10 (1998) 553-556.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Ocak 2020

Gönderilme Tarihi

4 Aralık 2019

Kabul Tarihi

6 Ocak 2020

Yayımlandığı Sayı

Yıl 1970 Cilt: 4 Sayı: 1

Kaynak Göster

APA
Kızıloluk, D., Gökçe, G., & Akkuş Çetinus, Ş. (2020). ELECTROCHEMICAL DETERMINATION OF THE INTERACTION BETWEEN ANTICANCER DRUG CAPECITABINE AND DNA BY CARBON PASTE ELECTRODE. Journal of Scientific Perspectives, 4(1), 1-12. https://doi.org/10.26900/jsp.4.001