The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study

Öz

Aim: In carbon monoxide poisoning, hypoxia results in neuronal damage and death of brain cells. It is considered that cerebral edema occurs consequently, with an associated increase in intracranial pressure. The present study evaluates the presence of increased intracranial pressure using the measurement of optic nerve sheath diameter by ultrasonography in patients presenting with carbon monoxide poisoning. Material and Method: Twenty-eight patients diagnosed with carbon monoxide poisoning after presenting to the emergency department underwent the bilateral measurement of optic nerve sheath diameter by ultrasonography. In addition, the patient’s demographic data, laboratory results, stage of the poisoning, and optic nerve sheath diameters were recorded. Results: The median optic nerve sheath diameter on the right and left sides was greater than 5 mm. The optic nerve sheath diameter of the right and the left eye was significantly higher in patients with severe carbon monoxide poisoning than in those with moderate and mild poisoning. Conclusion: The optic nerve sheath diameter measurement can be used to evaluate increased intracranial pressure in patients with carbon monoxide poisoning.

Anahtar Kelimeler

Kaynakça

  1. 1. Smollin C, Olson K. Carbon monoxide poisoning (acute). BMJ Clin Evid. 2010;2010.
  2. 2. Eichhorn L, Thudium M, Jüttner B. The Diagnosis and Treatment of Carbon Monoxide Poisoning. Dtsch Arztebl Int. 2018;115(51-52):863–870.
  3. 3. Saria MG, Kesari S. Increased Intracranial Pressure: The Use of an Individualized Ladder Approach. Seminars in oncology nursing. 2021:151133.
  4. 4. Chung-Ping Lo, Shao-Yuan Chen, Kwo-Whei Lee, Wei-Liang Chen, Cheng-Yu Chen et al. Brain injury after acute carbon monoxide poisoning: early and late complications. AJR Am J Roentgenol 189(4):W205-211.
  5. 5. Kavak N, Doğan B, Sultanoğlu H, Kavak RP, Özdemir MJKD. Clinical and Magnetic Resonance Imaging Findings of Patients with Acute Carbon Monoxide Poisoning.12(3):443-50.
  6. 6. Girisgin AS, Kalkan E, Kocak S, Cander B, Gul M, et al. The role of optic nerve ultrasonography in the diagnosis of elevated intracranial pressure. Emerg Med J. 2007;24(4):251–4.
  7. 7. Robba C, Santori G, Czosnyka M, Corradi F, Bragazzi N, et al.Optic nerve sheath diameter measured sonographically as noninvasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018;44(8):1284–1294.
  8. 8. Miller MT, Pasquale M, Kurek S, White J, Martin P, et al. Initial head computed tomographic scan characteristics have a linear relationship with initial intracranial pressure after trauma. J Trauma. 2004;56(5):967–72.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Klinik Tıp Bilimleri

Bölüm

Araştırma Makalesi

Yazarlar

Emel Altıntaş Bu kişi benim
Türkiye

Sertaç Güler Bu kişi benim
Türkiye

Hayri Ramadan Bu kişi benim
Türkiye

Yayımlanma Tarihi

26 Nisan 2023

Gönderilme Tarihi

17 Kasım 2021

Kabul Tarihi

18 Ocak 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 13 Sayı: 1

Kaynak Göster

APA
Altıntaş, E., Güler, S., & Ramadan, H. (2023). The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study. Kafkas Journal of Medical Sciences, 13(1), 1-5. https://izlik.org/JA98KZ64GH
AMA
1.Altıntaş E, Güler S, Ramadan H. The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study. KAFKAS TIP BİL DERG. 2023;13(1):1-5. https://izlik.org/JA98KZ64GH
Chicago
Altıntaş, Emel, Sertaç Güler, ve Hayri Ramadan. 2023. “The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study”. Kafkas Journal of Medical Sciences 13 (1): 1-5. https://izlik.org/JA98KZ64GH.
EndNote
Altıntaş E, Güler S, Ramadan H (01 Nisan 2023) The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study. Kafkas Journal of Medical Sciences 13 1 1–5.
IEEE
[1]E. Altıntaş, S. Güler, ve H. Ramadan, “The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study”, KAFKAS TIP BİL DERG, c. 13, sy 1, ss. 1–5, Nis. 2023, [çevrimiçi]. Erişim adresi: https://izlik.org/JA98KZ64GH
ISNAD
Altıntaş, Emel - Güler, Sertaç - Ramadan, Hayri. “The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study”. Kafkas Journal of Medical Sciences 13/1 (01 Nisan 2023): 1-5. https://izlik.org/JA98KZ64GH.
JAMA
1.Altıntaş E, Güler S, Ramadan H. The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study. KAFKAS TIP BİL DERG. 2023;13:1–5.
MLA
Altıntaş, Emel, vd. “The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study”. Kafkas Journal of Medical Sciences, c. 13, sy 1, Nisan 2023, ss. 1-5, https://izlik.org/JA98KZ64GH.
Vancouver
1.Emel Altıntaş, Sertaç Güler, Hayri Ramadan. The Ultrasound Examination of the Optic Nerve Sheath Diameter in the Patients Presenting with Carbon Monoxide Poisoning: A pilot study. KAFKAS TIP BİL DERG [Internet]. 01 Nisan 2023;13(1):1-5. Erişim adresi: https://izlik.org/JA98KZ64GH