Editöre Mektup

Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients

Cilt: 6 Sayı: 1 1 Mart 2016
  • Hatice Bahadır
  • Hediye Ayla Tür
  • Cengiz Kaya
  • Ersin Köksal
  • Yasemin Burcu Üstün
  • Elif Bengi Şener
  • Ahmet Dilek
PDF İndir
TR EN

Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients

Öz

To compare a lighted intubation stylet (LIS), Storz DCI videolaryngoscope, and Macintosh laryngoscope regarding endotracheal intubation (ETI) times, the number of intubation attempts required, hemodynamic findings, and complications related to intubation-extubation. Methods: A total of 60 patients age 18-65 with American Society of Anesthesiologists score I-II and Mallampati score I-II, who were scheduled for elective surgery, were randomized into 3 groups: Group I, on which ETI was performed using the LIS; Group V, on which ETI was performed using the Storz DCI videolaryngoscope; and Group L, on which ETI was performed using the Macintosh laryngoscope. For each study group, ETI was applied by an operator who had previously performed at least 15 successful endotracheal intubations. Heart rates (HRs), mean arterial pressure (MAP), and peripheral oxygen saturation (SpO2) were recorded before and after induction, immediately, and 1, 2, 3, 4, and 5 minutes after ETI. However, ETCO2 was recorded immediately, and 1, 2, 3, 4, and 5 minutes after ETI. In addition, the number of attempts required to achieve ETI, ETI-related complications, and ETI times were noted. Potential complications were recorded immediately, and also 2 and 6 hours after extubation. Results: The demographic characteristics of the patients, ETI times, HR, MAP, ETCO2, and SpO2 did not differ between groups. Immediately after extubation, complications (stridor, coughing) were seen in 2 (10%) patients in Group L; however, they weren’t observed in other groups (p=0.362). Sore throat was seen in Groups I (n=2; 10%), V (n=1; 5) and L (n02; 10 %) (p=0.804). Two hours after extubation, sore throat was observed in one (5%) patient in both Group I and L (p=0.596). Conclusion: There wasn’t difference between the LIS, Storz-DCI videolaryngoscope and Macintosh laryngoscope with respect to hemodynamic parameters, the number of ETI trials, ETI times, and related complications.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

Klinik Tıp Bilimleri

Bölüm

Editöre Mektup

Yazarlar

Hatice Bahadır Bu kişi benim

Hediye Ayla Tür Bu kişi benim

Cengiz Kaya Bu kişi benim

Ersin Köksal Bu kişi benim

Yasemin Burcu Üstün Bu kişi benim

Elif Bengi Şener Bu kişi benim

Ahmet Dilek Bu kişi benim

Yayımlanma Tarihi

1 Mart 2016

Gönderilme Tarihi

1 Mart 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2016 Cilt: 6 Sayı: 1

Kaynak Göster

APA
Bahadır, H., Tür, H. A., Kaya, C., Köksal, E., Üstün, Y. B., Şener, E. B., & Dilek, A. (2016). Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients. Kafkas Journal of Medical Sciences, 6(1), 8-13. https://izlik.org/JA85SE66TT
AMA
1.Bahadır H, Tür HA, Kaya C, vd. Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients. KAFKAS TIP BİL DERG. 2016;6(1):8-13. https://izlik.org/JA85SE66TT
Chicago
Bahadır, Hatice, Hediye Ayla Tür, Cengiz Kaya, vd. 2016. “Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients”. Kafkas Journal of Medical Sciences 6 (1): 8-13. https://izlik.org/JA85SE66TT.
EndNote
Bahadır H, Tür HA, Kaya C, Köksal E, Üstün YB, Şener EB, Dilek A (01 Mart 2016) Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients. Kafkas Journal of Medical Sciences 6 1 8–13.
IEEE
[1]H. Bahadır vd., “Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients”, KAFKAS TIP BİL DERG, c. 6, sy 1, ss. 8–13, Mar. 2016, [çevrimiçi]. Erişim adresi: https://izlik.org/JA85SE66TT
ISNAD
Bahadır, Hatice - Tür, Hediye Ayla - Kaya, Cengiz - Köksal, Ersin - Üstün, Yasemin Burcu - Şener, Elif Bengi - Dilek, Ahmet. “Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients”. Kafkas Journal of Medical Sciences 6/1 (01 Mart 2016): 8-13. https://izlik.org/JA85SE66TT.
JAMA
1.Bahadır H, Tür HA, Kaya C, Köksal E, Üstün YB, Şener EB, Dilek A. Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients. KAFKAS TIP BİL DERG. 2016;6:8–13.
MLA
Bahadır, Hatice, vd. “Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients”. Kafkas Journal of Medical Sciences, c. 6, sy 1, Mart 2016, ss. 8-13, https://izlik.org/JA85SE66TT.
Vancouver
1.Hatice Bahadır, Hediye Ayla Tür, Cengiz Kaya, Ersin Köksal, Yasemin Burcu Üstün, Elif Bengi Şener, Ahmet Dilek. Comparative evaluation of the lighted intubation stylet, Storz DCI videolaryngoscope, and Macintosh laryngoscope in adult patients. KAFKAS TIP BİL DERG [Internet]. 01 Mart 2016;6(1):8-13. Erişim adresi: https://izlik.org/JA85SE66TT