Öz

In order to protect the lives of the occupants and to minimize the possible damages to a property from a fire, it is great importance to accurately calculate the occupancy load of a building both in the Turkey’s National Occupational Health and Safety (OHS) legislation and in the American National Fire Protection Association (NFPA). In this research, the building occupancy load calculations were compared with NFPA 101-Life Safety Code 2018 within the scope of the "Turkey's Regulation on the Protection of Buildings from Fire" (ROPBF), which was first published in the Official Gazette on 19.12.2007 and then revised on 10.08.2009. The scope of the research also contains calculation methodology for the occupancy loads and what to consider in buildings that is used by both legal entities and real persons. The correct determination of the "Occupancy load", which is the most basic component of calculating and designing the required number of emergency exits, sizes, widths represents one of the most important and key component of an OHS measure to be taken before a fire occurs.

Anahtar Kelimeler

Kaynakça

  1. Binaların Yangından Korunması Hakkındaki Yönetmelik (BYKHY), (2007). Resmî Gazete, Sayı 26735, NFPA 101, (2018). Life Safety Code.
  2. NFPA 13, (2019). Standard for the Installation of Sprinkler Systems.
  3. NFPA 1, (2018). Fire Code...........................
  4. Yıldız, Z. (2020). Bir Üniversite Araştırma Hastanesinin Aktif Yangın Güvenlik Önlemlerinin Değerlendirilmesi . Engineering Sciences , 15 (2) , 100-112 .
  5. Gönüllüoğlu, S. (2018). Yangınla İlgili Mevzuatlar Çerçevesinde Yüksek Ofis Binalarında Kaçış Yollarının Analizi ve Bir Örnek Çalışma. Yüksek Lisans Tezi, Gazi Üniversitesi Fen Bilimleri Enstitüsü, Ankara.
  6. Muha, T. (2012). Evaluating Occupant Load Factors for Business Operations. An Interactive Qualifying Project report completed as required of the Bachelor of Science degree at Worcester Polytechnic Institute.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Derleme

Yayımlanma Tarihi

15 Haziran 2022

Gönderilme Tarihi

31 Aralık 2021

Kabul Tarihi

18 Mart 2022

Yayımlandığı Sayı

Yıl 2022 Cilt: 15 Sayı: 2

Kaynak Göster

APA
Serttaş, O., & Olcay, Z. F. (2022). Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA. Kent Akademisi, 15(2), 879-895. https://doi.org/10.35674/kent.1051420
AMA
1.Serttaş O, Olcay ZF. Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA. Kent Akademisi. 2022;15(2):879-895. doi:10.35674/kent.1051420
Chicago
Serttaş, Orkun, ve Zeynep Feride Olcay. 2022. “Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA”. Kent Akademisi 15 (2): 879-95. https://doi.org/10.35674/kent.1051420.
EndNote
Serttaş O, Olcay ZF (01 Haziran 2022) Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA. Kent Akademisi 15 2 879–895.
IEEE
[1]O. Serttaş ve Z. F. Olcay, “Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA”, Kent Akademisi, c. 15, sy 2, ss. 879–895, Haz. 2022, doi: 10.35674/kent.1051420.
ISNAD
Serttaş, Orkun - Olcay, Zeynep Feride. “Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA”. Kent Akademisi 15/2 (01 Haziran 2022): 879-895. https://doi.org/10.35674/kent.1051420.
JAMA
1.Serttaş O, Olcay ZF. Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA. Kent Akademisi. 2022;15:879–895.
MLA
Serttaş, Orkun, ve Zeynep Feride Olcay. “Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA”. Kent Akademisi, c. 15, sy 2, Haziran 2022, ss. 879-95, doi:10.35674/kent.1051420.
Vancouver
1.Orkun Serttaş, Zeynep Feride Olcay. Comparison of Building Occupancy Loads with the Turkey’s Regulation on the Protection of Buildings from Fire and NFPA. Kent Akademisi. 01 Haziran 2022;15(2):879-95. doi:10.35674/kent.1051420

Cited By

Kent Akademisi | Kent Kültürü ve Yönetimi Dergisi / Urban Academy | Journal of Urban Culture and Management

*****
Information, Communication, Art and Media Network (ICAM Network) | www.icamnetwork.net
Address: Ahmet Emin Fidan Culture ve Araştırma Merkezi, Evkaf Mah. Evkaf Sok. No: 34 Fatsa Ordu
Tel: +90452 310 20 30 | Publication Group Mail: info@icamnetwork.net | Journal Mail:  editor@kentakademisi.com