The relative humidity and temperature of the oil used for insulation purposes in transformers directly affect the breakdown voltage of the oil and accordingly the life of the transformer. Continuous monitoring of the moisture content and breakdown voltage of the transformer oil provides the basis for predictive maintenance practices. This study aims to develop a sensor to continuously monitor the moisture content of the insulating oil and to calculate the breakdown voltage approximately. In this context, firstly, measurements were taken with an industrial oil monitoring sensor which calculates the breakdown voltage in transformer oils with high accuracy and was verified with laboratory measurements. At the same time, EE364 by E+E™ and SHT10 by Sensirion™ also used for temperature and humidity measurements. By comparing the measured data with each other, a relationship was formulated between the humidity and temperature values and the breakdown voltage. As a result, an approximate breakdown voltage calculation method that can be used considering the characteristic parameters of transformer oil has been introduced. Thus, a cost-effective function has been developed that can be widely used for transformer monitoring systems.

Anahtar Kelimeler

Kaynakça

  1. [1] Dupont C., Beauchemin C., Buckley G., Bukvic M., 2015. Cigré Brochure 630 A2.44 -Guide On Transformer Intelligent Condition Monitoring (TICM) Systems. CIGRE Tech Broch.
  2. [2] Tenbohlen S., Jagers J., Bastos G., Desai B., Diggin B., 2015. Cigré Brochure 642 A2.37 -Transformer Reliability Survey. CIGRE Tech Broch.
  3. [3] Atanasova I., Agren P., Cucek B., Davidov V., 2018., Cigré Brochure 741 D1.52 -Moisture Measurement and Assessment in Transformer Insulation – Evaluation of Chemical Methods And Moisture Capacitive Sensors. CIGRE Tech Broch.
  4. [4] Pahlavanpour B., Pablo A., Tumiatti W., Martins M., 2010. Cigré Brochure 413 D1.01 -Insulating Oil Regeneration and Dehalogenation. CIGRE Tech Broch.
  5. [5] Solokov V., Aubin J., Davydov V., Gasser H., Griffin P., 2008. Cigré Brochure 349 A2.30 - Moisture Equilibrium and Moisture Migration Within Transformer Insulation Systems. CIGRE Tech Broch.
  6. [6] Du Y., 1999. Moisture equilibrium in transformer paper-oil systems. IEEE Electrical Insulation Magazine, 15, pp.11–20.
  7. [7] Julliard Y., Badent R., Schwab AJ., 2001. Influence of water content on breakdown behavior of transformer oil. Paper presented at Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Kitchener, Canada, 14-17 October, pp. 544–547.
  8. [8] Lewand L., 2002. Understanding Water in Transformer Systems. Neta World, pp. 1–4.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Mühendisliği

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

31 Mayıs 2024

Yayımlanma Tarihi

31 Mayıs 2024

Gönderilme Tarihi

13 Mayıs 2022

Kabul Tarihi

14 Mart 2023

Yayımlandığı Sayı

Yıl 2024 Cilt: 7 Sayı: 1

Kaynak Göster

APA
Güneş, D., Tekin, H., Alboyacı, B., & Yılmaz, Ö. (2024). Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor. Kocaeli Journal of Science and Engineering, 7(1), 9-19. https://doi.org/10.34088/kojose.1115308
AMA
1.Güneş D, Tekin H, Alboyacı B, Yılmaz Ö. Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor. KOJOSE. 2024;7(1):9-19. doi:10.34088/kojose.1115308
Chicago
Güneş, Doruk, Hüsnügül Tekin, Bora Alboyacı, ve Özgür Yılmaz. 2024. “Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor”. Kocaeli Journal of Science and Engineering 7 (1): 9-19. https://doi.org/10.34088/kojose.1115308.
EndNote
Güneş D, Tekin H, Alboyacı B, Yılmaz Ö (01 Mayıs 2024) Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor. Kocaeli Journal of Science and Engineering 7 1 9–19.
IEEE
[1]D. Güneş, H. Tekin, B. Alboyacı, ve Ö. Yılmaz, “Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor”, KOJOSE, c. 7, sy 1, ss. 9–19, May. 2024, doi: 10.34088/kojose.1115308.
ISNAD
Güneş, Doruk - Tekin, Hüsnügül - Alboyacı, Bora - Yılmaz, Özgür. “Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor”. Kocaeli Journal of Science and Engineering 7/1 (01 Mayıs 2024): 9-19. https://doi.org/10.34088/kojose.1115308.
JAMA
1.Güneş D, Tekin H, Alboyacı B, Yılmaz Ö. Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor. KOJOSE. 2024;7:9–19.
MLA
Güneş, Doruk, vd. “Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor”. Kocaeli Journal of Science and Engineering, c. 7, sy 1, Mayıs 2024, ss. 9-19, doi:10.34088/kojose.1115308.
Vancouver
1.Doruk Güneş, Hüsnügül Tekin, Bora Alboyacı, Özgür Yılmaz. Breakdown Voltage Estimation in Transformer Oils with Low-Cost Humidity Sensor. KOJOSE. 01 Mayıs 2024;7(1):9-19. doi:10.34088/kojose.1115308