EN
Human Head Transcranial Magnetic Stimulation Using Finite Element Method
Öz
Transcranial magnetic stimulation (TMS) is a wearable neuromodulation technique. It is approved for several therapies for various neurological disorders, including major depressive disorder, traumatic brain injury, Parkinson’s disease, and post-traumatic stress disorder. This method became an alternative neuromodulation technique for such brain-related disorders. However, it has shown significant improvement in this alternative approach. Studies based on this technique have shown limited efficacy. They might be associated with current levels, poor coil locality, optimal coil size, and neuromodulator settings. It has been shown in this research that coil heating is related to higher levels of current. Thus, it is required to analyze the impact of the current levels on the induced magnetic distribution to define the optimal current range for the TMS coils. It is not feasible to investigate this research with experimental tests and analytic methods. Alternatively, using an advanced computational model of the coils and accounting for different human head anatomical layers, coil current capacity can be optimized based on finite element magnetic field distribution. This paper aims to investigate the impact of the coil current levels on the induced magnetic field distribution. The current capacity of the coils can be optimized based on the required magnetic field. In this way, the overheating may be reduced and may result in increased efficacy. As a proof-of-concept, a prototype coil and multi-layered geometrical human head models were generated using geometric shapes. The fundamental human head tissue layers were generated based on their average thickness. The model was simulated based on a finite element magnetic simulation using appropriate boundary conditions and neuromodulator settings. The various coil current levels were applied to analyze the outcome. The models were simulated, and the results were recorded based on these current levels. Results showed that there is a direct relation between applied current levels and induced magnetic flux density in the region of interest.
Anahtar Kelimeler
Kaynakça
- [1] L. M. Koponen, J. O. Nieminen, T. P. Mutanen, M. Stenroos, and R. J. Ilmoniemi, 2017. Coil optimisation for transcranial magnetic stimulation in realistic head geometry. Brain Stimulation, 4, pp. 795–805.
- [2] M. Ghannad-Rezaie, P. M. Eimon, Y. Wu, and M. F. Yanik, 2019. Engineering brain activity patterns by neuromodulator polytherapy for treatment of disorders. Nature Communications, 10, pp. 1–13.
- [3] J. J. Mahoney, C. A. Hanlon, P. J. Marshalek, A. R. Rezai, and L. Krinke, 2020. Transcranial magnetic stimulation, deep brain stimulation, and other forms of neuromodulation for substance use disorders: Review of modalities and implications for treatment. Journal of the neurological sciences, 418, p. 117-149.
- [4] T. Denison and M. J. Morrell, 2022. Neuromodulation in 2035. Neurology, 98, pp. 65–72.
- [5] P. Rastogi, E. G. Lee, R. L. Hadimani, and D. C. Jiles, 2017. Transcranial Magnetic Stimulation-coil design with improved focality. Aip Advances, 7.
- [6] Kraus, Karl H., et al., 1993. The use of a cap-shaped coil for transcranial magnetic stimulation of the motor cortex. Journal of Clinical Neurophysiology, 10.3, pp. 353-362.
- [7] Roth, Y., Zangen, A., & Hallett, M., 2002. A coil design for transcranial magnetic stimulation of deep brain regions. Journal of Clinical Neurophysiology, 19, pp. 361-370.
- [8] Lontis, E. R., Voigt, M., & Struijk, J. J., 2006. Focality assessment in transcranial magnetic stimulation with double and cone coils. Journal of Clinical Neurophysiology, 23, pp. 463-472.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Biyomedikal Mühendisliği
Bölüm
Araştırma Makalesi
Erken Görünüm Tarihi
31 Mayıs 2024
Yayımlanma Tarihi
31 Mayıs 2024
Gönderilme Tarihi
24 Nisan 2023
Kabul Tarihi
13 Aralık 2023
Yayımlandığı Sayı
Yıl 2024 Cilt: 7 Sayı: 1
APA
Salkım, E., & Abut, T. (2024). Human Head Transcranial Magnetic Stimulation Using Finite Element Method. Kocaeli Journal of Science and Engineering, 7(1), 62-70. https://doi.org/10.34088/kojose.1279222
AMA
1.Salkım E, Abut T. Human Head Transcranial Magnetic Stimulation Using Finite Element Method. KOJOSE. 2024;7(1):62-70. doi:10.34088/kojose.1279222
Chicago
Salkım, Enver, ve Tayfun Abut. 2024. “Human Head Transcranial Magnetic Stimulation Using Finite Element Method”. Kocaeli Journal of Science and Engineering 7 (1): 62-70. https://doi.org/10.34088/kojose.1279222.
EndNote
Salkım E, Abut T (01 Mayıs 2024) Human Head Transcranial Magnetic Stimulation Using Finite Element Method. Kocaeli Journal of Science and Engineering 7 1 62–70.
IEEE
[1]E. Salkım ve T. Abut, “Human Head Transcranial Magnetic Stimulation Using Finite Element Method”, KOJOSE, c. 7, sy 1, ss. 62–70, May. 2024, doi: 10.34088/kojose.1279222.
ISNAD
Salkım, Enver - Abut, Tayfun. “Human Head Transcranial Magnetic Stimulation Using Finite Element Method”. Kocaeli Journal of Science and Engineering 7/1 (01 Mayıs 2024): 62-70. https://doi.org/10.34088/kojose.1279222.
JAMA
1.Salkım E, Abut T. Human Head Transcranial Magnetic Stimulation Using Finite Element Method. KOJOSE. 2024;7:62–70.
MLA
Salkım, Enver, ve Tayfun Abut. “Human Head Transcranial Magnetic Stimulation Using Finite Element Method”. Kocaeli Journal of Science and Engineering, c. 7, sy 1, Mayıs 2024, ss. 62-70, doi:10.34088/kojose.1279222.
Vancouver
1.Enver Salkım, Tayfun Abut. Human Head Transcranial Magnetic Stimulation Using Finite Element Method. KOJOSE. 01 Mayıs 2024;7(1):62-70. doi:10.34088/kojose.1279222
Cited By
Quantitative Assessment of Image Reconstruction Algorithms in Electrical Impedance Tomography
Kocaeli Journal of Science and Engineering
https://doi.org/10.34088/kojose.1556617