Pounding Response between RC Buildings with Equal Heights and Different Dynamic Characteristics Considering Seismic Zone 1 of Turkey
Öz
Interactions between inadequately separated neighboring buildings have been repeatedly observed during earthquakes. These interactions may result in substantial damage or even total destruction of colliding structures during strong ground motions. This study focuses on investigation of pounding response between RC buildings with equal heights and different dynamic characteristics considering Seismic Zone 1 of Turkey. A collision between buildings is represented by a pounding model commonly used in the literature, which is a nonlinear elastic spring (Hertz model). In this study, the considered ground motion records are scaled according to design spectrum given for Seismic Zone 1 in Turkish Earthquake Code 2007 (TEC–2007). Neighboring buildings are modelled as a three-dimensional beam-column system which is a widely constructed building type in Turkey. Pounding analyses of the neighboring buildings are performed in time domain by aid of SAP2000 program. Pounding forces obtained from the analyses are used to investigate the pounding response between buildings RC buildings with equal heights and different dynamic characteristics considering Seismic Zone 1 of Turkey. The results presented in this study represents that gap values defined in TEC–2007 are insufficient.
Anahtar Kelimeler
Kaynakça
- [1] Rosenblueth E., Meli R., “ The 1985 earthquake: Causes and effects in Mexico City” Concrete International, 8(5), 23-34, 1986
- [2] Kasai K., Maison B.F., “ Building Pounding Damage During The 1989 Loma Prieta Earthquake” Engineering Structures, 19(3), 195-207, 1997
- [3] Vasilliadis L., Elenas A., “ A performance of school buildings during the Athens earthquake of 7 September 1999” 12th European Conference on Earthquake Engineering, 264, 2002
- [4] Muthukumar S., “ A Contact Element Approach with Hysteresis Damping For The Analysis and Design of Pounding in Bridges” Georgia Institute of Technology, PhD Thesis, 240p, Georgia, 2003
- [5] Garcia D.L., “ Separation Distance Necessary to Prevent Seismic Pounding between Adjacent Structures” University of New York, PhD Thesis, Buffalo, 2004
- [6] Jankowski R., “ Non-linear viscoelastic modelling of earth-quake-induced structural pounding” Earthquake Engineering and Structural Dynamics, 34, 595-611, 2005
- [7] Muthukumar S., DesRoches R., “ A Hertz Contact Model with Non-linear damping for Pounding Simulation” Earthquake Engineering and Structural Dynamics, 35, 811-828, 2006
- [8] Jankowski R., “ Non-linear FEM analysis of earthquake induced pounding between the main building and the stair-way tower of the Olive View Hospital” Engineering Structures, 31, 1851-1864, 2009
Ayrıntılar
Birincil Dil
Türkçe
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yazarlar
Hasan Hüseyin Dertli
*
Bu kişi benim
BOZOK ÜNİVERSİTESİ
Türkiye
Fezayil Sunca
Cumhuriyet University
Türkiye
Mehmet Akköse
Bu kişi benim
Türkiye
Yayımlanma Tarihi
27 Aralık 2017
Gönderilme Tarihi
20 Haziran 2017
Kabul Tarihi
24 Ekim 2017
Yayımlandığı Sayı
Yıl 2017 Cilt: 6