The loss of
teeth impairs patients’ like appearance, masticatory and speech etc. These
functional disorders effect the quality of patients’ life standards. To restore
these functions, removable partial or complete dentures are often used. In this
study, the finite element method was used for carrying out stress analysis on midline of
maxillary denture. Temperature of 0 °C,
36 °C, 70 °C and
the suitable boundary conditions
were applied to specimens reinforced with CrCo, UD/woven carbon epoxy,
UD/woven glass epoxy, UD/woven kevlar epoxy. The results obtained show that
these reinforcements used to increase the strength of the prosthesis have high
thermal stresses under thermal loading compared to unreinforced specimens.
Maxillary denture Fiber reinforcement Stress analysis Relevance temperature and stress
Diş
sağlığını kaybeden hastalarda görüntü, çiğneme, konuşma gibi fonksiyonel
bozukluklar görülebilir. Bu fonksiyon bozuklukları insanın hayat standardını
direkt olarak etkilemektedir. Bu fonksiyon bozukluklarının giderilmesi amacıyla
çıkarılabilir kısmi veya tam protezler sıklıkla kullanılır. Bu
çalışmada, sonlu elemanlar metodu kullanılarak üst damak protezinin 0 °C,
36 °C, 70 °C sıcaklık ve uygun sınır koşulları
altında CrCo,
tek yönlü/örgü karbon epoksi, tek yönlü/örgü cam epoksi, tek yönlü/örgü kevlar
epoksi takviyeleri ile beraber, kritik
kırılma noktası başlangıcı olan orta hat bölgesinin gerilme analizi
incelenmiştir. Elde edilen sonuçlar göstermiştir ki protezlerin
dayanımını arttırmak için kullanılan bu takviyeler termal yükleme altında
takviyesiz numunelere göre yüksek oranda termal kaynaklı gerilmeler
oluşturmaktadır.
Üst damak protezi Fiber takviye Gerilme analizi Sıcaklık gerilme ilişkisi