In
motion control drives, speed measurement with high accuracy is an important
issue and has great influence on the motor performance. In this paper, speed
measurement techniques' affects for motion control in permanent
magnet synchronous machine (PMSM) with low resolution incremental encoder
are discussed. Conventional speed measurement techniques such as measuring
frequency method (M-method, measuring period method
(T-method) and measuring both frequency and period method (M/T-method) are
introduced. The simulation results are obtained in MATLAB/Simulink and the
experimental results are presented based on TMS320x28xxx. Simulation and
experimental comparative analysis of the various methods results show that
M-method is suitable for high speed measurement, T-method is suitable for low
speed measurement and M/T method is not related with speed and it works in both
low speed and high speed. So the M/T method is better than the M-method and
T-method and the speed measurement error is less than other methods with a high
precision in a wide speed range.
DSP Speed Measurement Motion Control Incremental Encoder Permanent Magnet Synchronous Machine (PMSM)
Konular | Mühendislik |
---|---|
Bölüm | Makaleler |
Yazarlar | |
Yayımlanma Tarihi | 19 Ocak 2018 |
Yayımlandığı Sayı | Yıl 2018 Cilt: 13 Sayı: 1 |