Potential Risk Factors in Development of the “Halo Sign” in Patients Performed Transpedicular Screw Fixation Through the Posterior Spinal Approach
Öz
It has been shown in literature that a fibrous tissue called "halo sign" in the radiological terminology can develop around the transpedicular screws implanted incompletely and/or incorrectly, which appears after movement of the screw in the cancellous bone. In this retrospective clinical study, 141 patients who underwent posterior spinal instrumentation for thoracic, lumbar or thoracolumbar vertebrae were evaluated using computed tomography (CT) and direct X-rays images for "halo sign" formation which refers in probable failure of spinal instrumentation. Hospital records included in the year 2014-2018 were examined and adult patients who were performed lumbar, thoracal, and thoracolumbar spinal instrumentation via posterior approach due to reasons such as "spine fracture", "spondylosis", "spondylolisthesis" and "intervertebral disc hernia" were included and evaluated in this study. The age and sex of the patients were recorded. Spinal X-ray and spinal CT images obtained during the postoperative follow-up period were examined. Halo sign was seen in 13 patients. Age (p=0.013), number of instrumented vertebrae (p=0.001) and number of transpedicular screws (p<0.001) values were different between the patients with halo sign and patients without halo sign. As a result, it was observed in this study that the formation of the halo sign in posterior spinal instrumentation system could develop in proportion to the number of transpedicular screw and patients' age. It was thought that the halo sign formation was not connected with the parameters called performed laminectomy, gender, inserted intervertebral cage, or vertebral region which were inserted transpedicular screws.
Anahtar Kelimeler
Kaynakça
- 1. Roy-Camille R, Saillant G, Mazel C. Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res. 1986; 203: 7-17.
- 2. George DC, Krag MH, Johnson CC, Van Hal ME, Haugh LD, Grobler LJ. Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine (Phila Pa 1976) 1991; 16(2): 181-184.
- 3. Moran JM, Berg WS, Berry JL, Geiger JM, Steffee AD. Transpedicular screw fixation. J Orthop Res. 1989; 7(1): 107-114.
- 4. Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ. Pedicle screw loosening: a clinically relevant complication? Eur Spine J. 2015; 24(5): 1005-1016.
- 5. Mohi Eldin MM, Ali AM. Lumbar transpedicular implant failure: a clinical and surgical challenge and its radiological assessment. Asian Spine J. 2014; 8(3): 281-297.
- 6. Tsuang FY, Chen CH, Wu LC, Kuo YJ, Lin SC, Chiang CJ. Biomechanical arrangement of threaded and unthreaded portions providing holding power of transpedicular screw fixation. Clin Biomech (Bristol, Avon). 2016; 39: 71-76.
- 7. Güvenç Y, Akyoldaş G, Şentürk S, Erbulut D, Yaman O, Özer AF. How to Reduce Stress on the Pedicle Screws In Thoracic Spine? Importance of Screw Trajectory: A Finite Element Analysis. Turk Neurosurg. 2017 Dec 25. doi: 10.5137/1019-5149.JTN.21895-17.2.
- 8. Alkaly RN, Bader DL. The Effect of Transpedicular Screw Design on Its Performance in Vertebral Bone Under Tensile Loads: A Parametric Study. Clin Spine Surg. 2016; 29(10): 433-440.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yazarlar
Mustafa Öğden
*
0000-0002-7129-0936
Türkiye
İbrahim Akkurt
Bu kişi benim
0000-0002-3693-7976
Yayımlanma Tarihi
17 Mart 2020
Gönderilme Tarihi
9 Nisan 2019
Kabul Tarihi
30 Nisan 2019
Yayımlandığı Sayı
Yıl 2020 Cilt: 42 Sayı: 2