EN
Square Wave and Differential Pulse Voltammetric Determination of Meloxicam in Pharmaceutical Formulations
Abstract
Two new voltammetric methods (square wave (SWV) and differential pulse (DPV)) were developed and validated for the direct determination of meloxicam (MX) in pharmaceutical formulations (PFs) without any pre-processes steps. The anodic peaks were obtained in buffer (pH 4.85) on glassy carbon electrode (GCE). The both voltammetric methods were linear at concentration range of 10-90 µg/mL in PF. The validation of methods for MX in PF were determined by establishing specificity, linearity, sensitivity, precision, accuracy, recovery and ruggedness. The recovery results of MX in PFs were found as % 98.5 for SWV and % 98.7 for DPV, respectively. The both developed voltammetric methods were successfully applied for the determination of MX in PFs named Melox, Melcam and Zeloxim. The endogenous substances found in PF were not create electroactive interferences for determine MX. The obtained analysis results of the PFs containing MX by voltammetric methods were compared by using the student t-test with the claimed values and no found statistically differences. It is claimed that new voltammetric methods can be used routinely MX analysis in PFs.
Keywords
Kaynakça
- 1. Phillips WJ, Currier BL, Analgesic pharmacology: II. Specific analgesics. JAAOSJournal of the American Academy of Orthopaedic Surgeons. 2004; 12; 221-233.
- 2. Shekelle PG, Newberry SJ, FitzGerald JD, Motala A, O'Hanlon CE, Tariq A, et al, Management of gout: a systematic review in support of an American College of Physicians clinical practice guideline. Annals of internal medicine. 2017; 166; 37- 51.
- 3. Soh J-W, Weinstein IB, Role of COX-independent targets of NSAIDs and related compounds in cancer prevention and treatment. Progress in experimental tumor research. 2003; 37; 261-283.
- 4. Pojarani LB, Zarifiazar S, Formulation and chracterization of meloxicam loaded niosome-based hydrogel formulations for topical applications. EMU Journal of Pharmaceutical Sciences. 2020; 3; 194-204.
- 5. Zawilla N, Mohammad MA-A, Aly SE-M, Determination of meloxicam in bulk and pharmaceutical formulations. Journal of pharmaceutical and biomedical analysis. 2003; 32; 1135-1144.
- 6. Garcia MS, Sánchez-Pedreño C, Albero MI, Marti J, Spectrophotometric methods for determining meloxicam in pharmaceuticals using batch and flow-injection procedures. European journal of pharmaceutical sciences. 2000; 9; 311-316.
- 7. Taha EA, Salama NN, Fattah LE-SA, Spectrofluorimetric and spectrophotometric stability-indicating methods for determination of some oxicams using 7-chloro-4-nitrobenz-2-oxa-1, 3-diazole (NBD-Cl). Chemical and pharmaceutical bulletin. 2006; 54; 653-658.
- 8. Bebawy LI, Stability-indicating method for the determination of meloxicam and tetracaine hydrochloride in the presence of their degradation products. Spectroscopy letters. 1998; 31; 797-820.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Eczacılık ve İlaç Bilimleri
Bölüm
Araştırma Makalesi
Yazarlar
Yayımlanma Tarihi
25 Ocak 2022
Gönderilme Tarihi
1 Aralık 2021
Kabul Tarihi
7 Ocak 2022
Yayımlandığı Sayı
Yıl 2022 Cilt: 2 Sayı: 1