Araştırma Makalesi

A novel Cu(II) detection assay via modified glassy carbon electrode

Cilt: 24 Sayı: 7 28 Aralık 2018
PDF İndir
TR EN

A novel Cu(II) detection assay via modified glassy carbon electrode

Abstract

Copper (Cu(II)) is an essential and necessary micronutrient for many plants and animals at very low levels. However, it is toxic to aquatic plants at high levels due to its association with cell membranes. Glassy carbon electrode (GCE) was modified by the 3-phenyl-4-[2-(2-naphthylsulfonyloxy)-benzylidenamino]-4,5-dihydro-1H-1,2,4-triazol-5-one (3-PNO) in 0.1 M supporting electrolyte. The modified surface was confirmed by cyclic voltammetry (CV) and x-ray photoelectron spectroscopy (XPS). According to characterization data, the GCE with 3-PNO was successfully obtained. The GCE with 3-PNO was utilized for Cu(II) ions analysis in water samples. The concentration range and the limit of detection (LOD) were 1.0×10-10 - 2.0×10-8 M and 2.0×10-11 M (S/N = 3), respectively.

Keywords

Kaynakça

  1. Parmar P, Daya S. “The effect of copper on (3H)-tryptophan metabolism in organ cultures of rat pineal glands”. Metabolic Brain Disease, 16, 199-205, 2001.
  2. Zhou Y, Wang S, Zhang K, Jiang X. “Visual detection of copper(II) by azide-and alkyne-functionalized gold nanoparticles using click chemistry”. Angewandte Chemie International Edition, 47, 7454-7456, 2008.
  3. Liu C, Bai R, Ly QS. “Selective removal of copper and lead ions by diethylenetriamine-functionalized adsorbent: Behaviors and mechanisms”. Water Research, 42, 1511- 1522, 2008.
  4. Peric J, Trgo M, Medvidovic NV. “Removal of zinc, copper and lead by natural zeolite-a comparison of adsorption isotherms”. Water Research, 38, 1893-1899, 2004.
  5. Gupta VK, Yola ML, Atar N, Solak AO, Uzun L, Üstündağ Z. “Electrochemically modified sulfisoxazole nanofilm on glassy carbon for determination of cadmium(II) in water samples”. Electrochimica Acta, 105, 149-156, 2013.
  6. Oztekin Y, Tok M, Nalvuran H, Kiyak S, Gover T, Yazicigil Z, Ramanaviciene A, Ramanavicius A. “Electrochemical modification of glassy carbon electrode by poly-4-nitroaniline and its application for determination of copper(II)”. Electrochimica Acta, 56, 387-395, 2010.
  7. Oztekin Y, Krikstolaityte V, Ramanaviciene A, Yazicigil Z, Ramanavicius A. “1,10-Phenanthroline derivatives as mediators for glucose oxidase”. Biosensors and Bioelectronics, 26, 267-270, 2010.
  8. Yola ML, Atar N. “A novel voltammetric sensor based on gold nanoparticles involved in p-aminothiophenol functionalized multi-walled carbon nanotubes: Application to the simultaneous determination of quercetin and rutin”. Electrochimica Acta, 119, 24-31, 2014.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

28 Aralık 2018

Gönderilme Tarihi

18 Aralık 2016

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2018 Cilt: 24 Sayı: 7

Kaynak Göster

APA
Akyıldırım, O., Yüksek, H., Gürsoy Kol, Ö., Manap, S., Beytur, M., & Yola, M. L. (2018). A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 24(7), 1284-1286. https://izlik.org/JA96NZ67YL
AMA
1.Akyıldırım O, Yüksek H, Gürsoy Kol Ö, Manap S, Beytur M, Yola ML. A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2018;24(7):1284-1286. https://izlik.org/JA96NZ67YL
Chicago
Akyıldırım, Onur, Haydar Yüksek, Özlem Gürsoy Kol, Sevda Manap, Murat Beytur, ve Mehmet Lütfi Yola. 2018. “A novel Cu(II) detection assay via modified glassy carbon electrode”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 24 (7): 1284-86. https://izlik.org/JA96NZ67YL.
EndNote
Akyıldırım O, Yüksek H, Gürsoy Kol Ö, Manap S, Beytur M, Yola ML (01 Aralık 2018) A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 24 7 1284–1286.
IEEE
[1]O. Akyıldırım, H. Yüksek, Ö. Gürsoy Kol, S. Manap, M. Beytur, ve M. L. Yola, “A novel Cu(II) detection assay via modified glassy carbon electrode”, Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, c. 24, sy 7, ss. 1284–1286, Ara. 2018, [çevrimiçi]. Erişim adresi: https://izlik.org/JA96NZ67YL
ISNAD
Akyıldırım, Onur - Yüksek, Haydar - Gürsoy Kol, Özlem - Manap, Sevda - Beytur, Murat - Yola, Mehmet Lütfi. “A novel Cu(II) detection assay via modified glassy carbon electrode”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 24/7 (01 Aralık 2018): 1284-1286. https://izlik.org/JA96NZ67YL.
JAMA
1.Akyıldırım O, Yüksek H, Gürsoy Kol Ö, Manap S, Beytur M, Yola ML. A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2018;24:1284–1286.
MLA
Akyıldırım, Onur, vd. “A novel Cu(II) detection assay via modified glassy carbon electrode”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, c. 24, sy 7, Aralık 2018, ss. 1284-6, https://izlik.org/JA96NZ67YL.
Vancouver
1.Onur Akyıldırım, Haydar Yüksek, Özlem Gürsoy Kol, Sevda Manap, Murat Beytur, Mehmet Lütfi Yola. A novel Cu(II) detection assay via modified glassy carbon electrode. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi [Internet]. 01 Aralık 2018;24(7):1284-6. Erişim adresi: https://izlik.org/JA96NZ67YL