Micro-Sized glucose biosensor based on composite pH sensor
Öz
Today's
scientific and technical advances have led to significant advances in biosensor
technology, leading to widespread use of biosensors in areas such as food
technology, the environment, pharmaceuticals and clinical diagnostics,
biochemistry, and analytical chemistry. Improvements in the ion-selective
sensor technology used in the preparation of potentiometric biosensors and the
increase in the number of sensor materials have also accelerated the
development of new types of potentiometric biosensors. Thus, in this study,
information is given on the development of a new micro sized potentiometric
glucose biosensor based on composite pH sensor. Glucose oxidase was immobilized
on the composite layer as the biorecognition element. The surface of glucose
biosensor based composite pH sensing matrices was first examined for
electrochemical elucidation by using cyclic voltammetry and electrochemical
impedance spectroscopy. The rate of electron transfer resulted in a stable
response behavior of the biosensor and made it a suitable potentiometric sensor
for detection of glucose. A linear response in concentration range from 5x10-5
to 1x10-1 mol/L was obtained with a detection limit of 2x10-5
mol/L for the potentiometric detection of glucose. The biosensor exhibited a
fast response time (10 s), had good stability, and an extended lifetime.
Anahtar Kelimeler
Kaynakça
- Liu Y, Yu T. “Polymers and enzyme biosensors”. Journal of Macromolecular Science-Reviews in Macromolecular Chemistry & Physics, 37( 3), 459-500, 1997.
- Ófagain C. “Enzyme stabilization-recent experimental progress”. Enzyme and Microbial Technology, 33(2-3) 137-149, 2003.
- Ófagain C, Ruzgas T, Gorton L, Csoregi E, Ardila GB, Sakharov IU, Gazaryan, I.G. “Biosensors based on novel peroxidases with improved properties in direct and mediated electron transfer”. Biosensors and Bioelectronics, 15(9-10), 491- 497, 2000.
- Finfer S, Chittock DR, Su SY, Blair D, Foster D, Dhingra V, Ronco JJ. “Intensive versus conventional glucose control in critically ill patients”. The New England Journal of Medicine - Journals, 360(13),1283-1297, 2009.
- Wiener R, Wiener D, Larson R. “Benefits and risks of tight glucose control in critically ill adults: a meta-analysis”. Journal of the American Medical Association, 300(8), 933- 944, 2008.
- Krinsley J, Grover A. “Severe hypoglycemia in critically ill: risk and outcomes”. The Journal of Critical Care Medicine, 36(4), 1390-1391, 2008.
- Anger K, Szumita P. “Barriers to glucose control in the intensive care unit”. Pharmacotherapy, 26(2), 214-228, 2006.
- Vriesendorp T, Devries J, Holleman F, Dzoljic M, Hoekstra J. “The use of two continuous glucose sensors during and after surgery”. Diabetes Technology and Therapeutics- Journals, 7(2), 315-322, 2005.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
28 Aralık 2018
Gönderilme Tarihi
13 Ekim 2017
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2018 Cilt: 24 Sayı: 7