Abstract

This study's main purpose is to manufacture a low-cost, highly functional, myoelectric signal-controlled prosthetic hand for amputees in developing countries below a certain economic level. In this study, a prosthetic hand with five fingers was modeled on 15-degree freedom, and an independent joint movement was achieved through the use of a separate motor actuator for each joint in the fingers. The hand of the prosthetic can therefore keep the objects in the best possible way. The prosthetic was produced by hand using PLA material on a 3D printer to reduce cost. Bioelectric signals provide the human-prosthetic hand interaction, i.e. identification of the form of hand gesture. With 97 percent progress, the classification of a human hand with the SVM algorithm has been achieved. The prosthetic hand's total cost is US$ 450. The hand was compared in terms of qualitative and quantitative performance metrics with other high-priced rivals and the findings were interpreted.

Keywords

Kaynakça

  1. [1] World Health Organization.“World Report on Disability”. New York, NY: World Health Organization, 2011. https://www.who.int/disabilities/world_report/2011/report.pdf (24.09.2019).
  2. [2] Hamner SR, Narayan VG, Donaldson, KM. “Designing for scale: Development of the remotion knee for global emerging markets”. Annals of Biomedical Engineering, 41(9), 1851-1859, 2013.
  3. [3] Borne A, Porter A, Recicar J, Maxson, T and Montgomery C. “Pediatric Traumatic Amputations in the United States”. Journal of Pediatric Orthopaedics, 37(2), 104-107, 2017.
  4. [4] Strait E. “Prosthetics in Developing Countries.” http://www.oandp.org/publications/resident/pdf/DevelopingCountries.pdf. (25.05.2010).
  5. [5] Smith M. “Engadget-new bebionic hand almost doubles its grip-strength, steered by users’ electrical skin signals”. http://www.engadget.com/2012/09/07/bebionic-3-bionic-hand/ (24.09.2019).
  6. [6] Webster G. “The bionic hand with the human touch”. https://edition.cnn.com/2013/02/01/tech/bionic-hand-ilimb-prosthetic/index.html. (24.09.2019).
  7. [7] Lightbody S. “Design of an Articulated Thumb for a Low-Cost Prosthetic Hand”. Department of Engineering, Sweet Briar College, Lecturer Notes, Virginia, ABD.
  8. [8] Marrero IC. “Hand Anatomy”. http://emedicene.medscape.com/article/1285060-overview. (01.01.2010).

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Beyda Taşar Bu kişi benim
Türkiye

Arif Gülten Bu kişi benim
Türkiye

Oğuz Yakut Bu kişi benim
Türkiye

Yayımlanma Tarihi

23 Ekim 2020

Gönderilme Tarihi

24 Eylül 2019

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2020 Cilt: 26 Sayı: 5

Kaynak Göster

APA
Taşar, B., Gülten, A., & Yakut, O. (2020). Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 26(5), 884-892. https://izlik.org/JA47TH29MT
AMA
1.Taşar B, Gülten A, Yakut O. Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2020;26(5):884-892. https://izlik.org/JA47TH29MT
Chicago
Taşar, Beyda, Arif Gülten, ve Oğuz Yakut. 2020. “Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 26 (5): 884-92. https://izlik.org/JA47TH29MT.
EndNote
Taşar B, Gülten A, Yakut O (01 Ekim 2020) Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 26 5 884–892.
IEEE
[1]B. Taşar, A. Gülten, ve O. Yakut, “Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand”, Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, c. 26, sy 5, ss. 884–892, Eki. 2020, [çevrimiçi]. Erişim adresi: https://izlik.org/JA47TH29MT
ISNAD
Taşar, Beyda - Gülten, Arif - Yakut, Oğuz. “Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 26/5 (01 Ekim 2020): 884-892. https://izlik.org/JA47TH29MT.
JAMA
1.Taşar B, Gülten A, Yakut O. Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2020;26:884–892.
MLA
Taşar, Beyda, vd. “Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, c. 26, sy 5, Ekim 2020, ss. 884-92, https://izlik.org/JA47TH29MT.
Vancouver
1.Beyda Taşar, Arif Gülten, Oğuz Yakut. Design and manufacturing of 15 DOF myoelectric controlled prosthetic hand. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi [Internet]. 01 Ekim 2020;26(5):884-92. Erişim adresi: https://izlik.org/JA47TH29MT