In this study, effect of changing of the shear wall ratio to interstorey drift in multistory reinforced concrete buildings with flat slab with continuous drop panel depending on the local site classes is investigated. For that purpose, an R/C frame structure and three shear wall frame structures with different shear wall ratio which have 7 and 9 stories are designed. These structures are analyzed according to response spectrum analysis in Turkish earthquake code for four local site classes. According to the analysis results, interstorey drifts are determined and are compared with boundary values in the earthquake code. According to obtained results, it is seen that, values of interstory drifts lie below limit values for 7 storey models which have 1 % shear wall and 9 storey models which have 1.5 % shear wall. In analysis SAP 2000 structural analysis program is used.
Local site class Shear wall ratio Interstorey drift Flat slab with continuous drop pane.
Bu çalışmada, zemin sınıfına bağlı olarak perde oranlarındaki değişimin sürekli tablalı kirişsiz döşemeli çok katlı betonarme yapılarda oluşturduğu göreli kat ötelemelerine etkisi incelenmiştir. Bu amaçla, çerçeveli ve üç adet farklı perde oranlarına sahip 7 ve 9 katlı düzenli betonarme yapı tasarlanmıştır. Tasarlanan yapıların analizleri deprem yönetmeliğimizdeki tepki spektrumu yöntemine göre dört farklı zemin sınıfına göre yapılmıştır. Analizler sonucunda göreli kat ötelemeleri belirlenmiş ve deprem yönetmeliğindeki sınır değerler ile karşılaştırılmıştır. Elde edilen sonuçlara göre göreli ötelenme değerlerinin 7 katlı modeller için % 1, 9 katlı modeller için % 1,5 perde oranında sınır değerlerin altında kaldığı görülmüştür. Çözümlerde SAP2000 yapı analiz programı kullanılmıştır.
Zemin sınıfı Perde oranı Göreli kat ötelemesi Sürekli tablalı kirişsiz döşeme.
Birincil Dil | Türkçe |
---|---|
Bölüm | Makale |
Yazarlar | |
Yayımlanma Tarihi | 1 Mart 2012 |
Yayımlandığı Sayı | Yıl 2012 Cilt: 18 Sayı: 3 |