Effect of resin photopolymerization on primary teeth pulpal temperature change
Öz
Purpose: The polymerization of restorative materials has the potential to increase pulpal temperature and may result in damage to the health of pulpal tissue. The aim of this study is to investigate the pulpal temperature change of primary teeth with two light-emitting diode (LED) light-curing units (LCUs) (Valo Cordless®, EliparTM DeepCure-S) and three restorative groups (Filtek™ Bulk Fill Flowable, Filtek™ Z250 Universal Restorative and empty cavity) by using a microcirculation model.
Material and methods: Ten sound human maxillary second primary molars were used. Standardized Class V cavity preparations were performed with a dentin thickness of 1 mm and restorative groups were cured with LED LCUs. The highest temperature point in the pulp chamber was recorded. A repeated measures ANOVA and paired samples t-test were used for analysis of the data (p<0.05).
Results: EliparTM DeepCure-S groups exceeded the accepted critical temperature point of 5.6°C for Z250, Bulk Fill, and empty cavity (7.6±0.36, 7.44±0.7, and 5.81±1.6, respectively). None of the groups cured with Valo Cordless® reached the critical point (5.35±0.54, 5.44±0.41, and 5.02±0.89, respectively). The values in the different groups cured with Valo Cordless® were not significantly different (p≥0.05), but empty cavity showed significantly lower temperature values than the composite resin groups when the EliparTM DeepCure-S device was used (p<0.05).
Conclusion: The study demonstrated a correlation between the increased power of LED LCUs and pulp damage in restorative procedures.
Anahtar Kelimeler
Kaynakça
- 1. Trowbridge HO, Kim S. Pulp development, structure and function. In: Cohen S, Burns RC. Pathways of the Pulp, 6th ed. St. Louis: Mosby, 1994;296-336. Available at: https://www.academia. edu/28876240/Pathways_of_the_pulp_COHEN_. Accessed January 22, 2023
- 2. Ozturk B, Usumez A, Ozturk AN, Ozer F. In vitro assessment of temperature change in the pulp chamber during cavity preparation. J Prosthet Dent 2004;91:436-440. https://doi.org/10.1016/S0022391304001131
- 3. Martins GR, Cavalcanti BN, Rode SM. Increases in intrapulpal temperature during polymerization of composite resin. J Prosthet Dent 2006;96:328-331. https://doi.org/10.1016/j.prosdent.2006.09.008
- 4. Dodge WW, Dale RA, Cooley RL, Duke ES. Comparison of wet and dry finishing of resin composites with aluminum oxide discs. Dent Mater 1991;7:18-20. https://doi.org/10.1016/0109-5641(91)90020-y
- 5. Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 1965;19:515-530. https://doi.org/10.1016/0030-4220(65)90015-0
- 6. Jakubinek MB, O'Neill C, Felix C, Price RB, White MA. Temperature excursions at the pulp-dentin junction during the curing of light-activated dental restorations. Dent Mater 2008;24:1468-1476. https://doi.org/10.1016/j.dental.2008.03.012
- 7. Kodonas K, Gogos C, Tziafa C. Effect of simulated pulpal microcirculation on intrachamber temperature changes following application of various curing units on tooth surface. J Dent 2009;37:485-490. https://doi.org/10.1016/j.jdent.2009.03.006
- 8. Uzel A, Buyukyilmaz T, Kayalioglu M, Uzel I. Temperature rise during orthodontic bonding with various light-curing units-an in vitro study. Angle Orthod 2006;76:330-334. https://doi.org/10.1043/0003-3219(2006)076[0330:TRDOBW]2.0.CO;2
Ayrıntılar
Birincil Dil
İngilizce
Konular
Tıbbi Fizyoloji
Bölüm
Araştırma Makalesi
Yazarlar
Erken Görünüm Tarihi
14 Haziran 2023
Yayımlanma Tarihi
1 Temmuz 2023
Gönderilme Tarihi
28 Şubat 2023
Kabul Tarihi
3 Nisan 2023
Yayımlandığı Sayı
Yıl 2023 Cilt: 16 Sayı: 3
APA
Erdoğan, Y., & Ertuğrul, İ. F. (2023). Effect of resin photopolymerization on primary teeth pulpal temperature change. Pamukkale Medical Journal, 16(3), 466-474. https://doi.org/10.31362/patd.1257746
AMA
1.Erdoğan Y, Ertuğrul İF. Effect of resin photopolymerization on primary teeth pulpal temperature change. Pam Tıp Derg. 2023;16(3):466-474. doi:10.31362/patd.1257746
Chicago
Erdoğan, Yıldırım, ve İhsan Furkan Ertuğrul. 2023. “Effect of resin photopolymerization on primary teeth pulpal temperature change”. Pamukkale Medical Journal 16 (3): 466-74. https://doi.org/10.31362/patd.1257746.
EndNote
Erdoğan Y, Ertuğrul İF (01 Temmuz 2023) Effect of resin photopolymerization on primary teeth pulpal temperature change. Pamukkale Medical Journal 16 3 466–474.
IEEE
[1]Y. Erdoğan ve İ. F. Ertuğrul, “Effect of resin photopolymerization on primary teeth pulpal temperature change”, Pam Tıp Derg, c. 16, sy 3, ss. 466–474, Tem. 2023, doi: 10.31362/patd.1257746.
ISNAD
Erdoğan, Yıldırım - Ertuğrul, İhsan Furkan. “Effect of resin photopolymerization on primary teeth pulpal temperature change”. Pamukkale Medical Journal 16/3 (01 Temmuz 2023): 466-474. https://doi.org/10.31362/patd.1257746.
JAMA
1.Erdoğan Y, Ertuğrul İF. Effect of resin photopolymerization on primary teeth pulpal temperature change. Pam Tıp Derg. 2023;16:466–474.
MLA
Erdoğan, Yıldırım, ve İhsan Furkan Ertuğrul. “Effect of resin photopolymerization on primary teeth pulpal temperature change”. Pamukkale Medical Journal, c. 16, sy 3, Temmuz 2023, ss. 466-74, doi:10.31362/patd.1257746.
Vancouver
1.Yıldırım Erdoğan, İhsan Furkan Ertuğrul. Effect of resin photopolymerization on primary teeth pulpal temperature change. Pam Tıp Derg. 01 Temmuz 2023;16(3):466-74. doi:10.31362/patd.1257746