Öz

In the first part of our study, a posture and gait analysis system, shortlycalled POGASYS, is developed to be used in quantifying the gait of the individuals,and tested with healthy individuals to obtain their gait parameters. POGASYS hastwo main components: The first component is the shoe module having fourdifferent types of installed sensors and mounted on the shoes of the individuals,and the second component is the computer module with a user friendly softwarethat is used to obtain the data from the sensors wirelessly and to analyze it. Morethan fifty gait parameters can be determined by POGASYS to utilize for thequantification of the diseases affecting the individuals’ gait patterns. In the secondpart of our study, the gait parameters will be examined to decide what parametersamong all of the parameters can be used to differentiate the hemiplegic patientsfrom the healthy individuals using POGASYS software. In this paper, which is thefirst part of our study, the designs of POGASYS hardware and software, theprocesses to determine the principal gait parameters and the results of the testsperformed by POGASYS are discussed

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Sibel Bakbak Bu kişi benim

Ramazan Kayacan Bu kişi benim

Yayımlanma Tarihi

4 Ocak 2015

Gönderilme Tarihi

30 Aralık 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2014 Cilt: 18 Sayı: 3

Kaynak Göster

APA
Bakbak, S., & Kayacan, R. (2015). Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS). Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 18(3), 21-34. https://izlik.org/JA63SY55UH
AMA
1.Bakbak S, Kayacan R. Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS). Süleyman Demirel Üniv. Fen Bilim. Enst. Derg. 2015;18(3):21-34. https://izlik.org/JA63SY55UH
Chicago
Bakbak, Sibel, ve Ramazan Kayacan. 2015. “Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS)”. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 18 (3): 21-34. https://izlik.org/JA63SY55UH.
EndNote
Bakbak S, Kayacan R (01 Ocak 2015) Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS). Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 18 3 21–34.
IEEE
[1]S. Bakbak ve R. Kayacan, “Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS)”, Süleyman Demirel Üniv. Fen Bilim. Enst. Derg., c. 18, sy 3, ss. 21–34, Oca. 2015, [çevrimiçi]. Erişim adresi: https://izlik.org/JA63SY55UH
ISNAD
Bakbak, Sibel - Kayacan, Ramazan. “Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS)”. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 18/3 (01 Ocak 2015): 21-34. https://izlik.org/JA63SY55UH.
JAMA
1.Bakbak S, Kayacan R. Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS). Süleyman Demirel Üniv. Fen Bilim. Enst. Derg. 2015;18:21–34.
MLA
Bakbak, Sibel, ve Ramazan Kayacan. “Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS)”. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, c. 18, sy 3, Ocak 2015, ss. 21-34, https://izlik.org/JA63SY55UH.
Vancouver
1.Sibel Bakbak, Ramazan Kayacan. Design of a Laboratory Independent Posture and Gait Analysis System (POGASYS). Süleyman Demirel Üniv. Fen Bilim. Enst. Derg. [Internet]. 01 Ocak 2015;18(3):21-34. Erişim adresi: https://izlik.org/JA63SY55UH

e-ISSN :1308-6529
Linking ISSN (ISSN-L): 1300-7688

Dergide yayımlanan tüm makalelere ücretiz olarak erişilebilinir ve Creative Commons CC BY-NC Atıf-GayriTicari lisansı ile açık erişime sunulur. Tüm yazarlar ve diğer dergi kullanıcıları bu durumu kabul etmiş sayılırlar. CC BY-NC lisansı hakkında detaylı bilgiye erişmek için tıklayınız.