Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants

Yıl 2014, Cilt: 18 Sayı: 3, 175 - 181, 04.01.2015

Öz

The use of dental implants to solve different problems in dentistry has been growing rapidly. The success rates of dental implants are also very important for patients. Depending on the bone level of patients, short dental implants are very popular and widely used by many dentists. Although many dentists are using short dental implants frequently, It can be guessed that there can be stability problems because of crown to implant ratios. In this study, it is aimed to find out the effects of dental implant and abutment lengths on stability of short dental implants. 3 different short dental implant design made with the use of Solidworks 2013. Abutment lengths were 3,5 mm, 4 mm, 4,5 mm, 5 mm and implant lengths were 5 mm, 6 mm, 7 mm for each model. Human mandible model is transferred from Computed Tomography. Then, each implant model is mounted to modeled mandible and Finite Element Analysis is performed for each model. In order to see the effects of implant number on stability, we performed same analysis by placing 4 implants to the mandible

Kaynakça

  • Discussion and Conclusion
  • For the loading conditions tested, the maximum stress values did not reach the yield strength of abutment
  • implant/abutment joint systems evaluated. It is seem that the implant is durable all condition dynamic loading and overload at the end of work. Implant can be designed and studied in computer environment before it is implemented on the patient. This will save time for the design and prevent any permanent damage caused by miss-implementation of implant.
  • Many retrospective clinical studies shows high failure

İmplant ve Abutment Boylarının Kısa Dental İmplantların Stabilitesi Üzerindeki Etkilerinin İncelenmesi

Yıl 2014, Cilt: 18 Sayı: 3, 175 - 181, 04.01.2015

Öz

Diş hekimliğinde bulunan farklı sorunları çözmek için dental implantların kullanımı hızla artmaktadır. Dental implantların başarı oranları da hastalar için oldukça önemlidir. Kısa dental implantlar, hastaların kemik seviyesine bağlı olarak çok popüler ve yaygın olarak pek çok diş hekimleri tarafından kullanılmaktadır. Birçok diş hekimi sık sık kısa diş implantları kullanmasına
rağmen, implant-kron oranlarından dolayı stabilite sorunlarının gerçekleşebileceği tahmin edilebilir. Bu çalışmada, implant ve abutment uzunluklarının kısa dental implantlardaki stabilite üzerine etkilerinin incelenmesi amaçlanmıştır. Üç farklı kısa implant tasarımı Solidworks 2013 programı kullanılarak tasarlanmıştır. Her bir model için abutment uzunlukları 3,5 mm, 4 mm, 4,5 mm ve 5 mm, implant uzunlukları da 5 mm, 6 mm, 7 mm olarak tasarlanmıştır. Insan çene kemiği Bilgisayarlı tomografi görüntülerinden transfer edilmiştir. Her bir implant modeli çene kemiğine implante edilerek Sonlu Elemanlar Analiz yöntemiyle analiz edilmiştir. İmplant sayısının stabilite üzerindeki etkisini görmek amacıyla, tamamen dişsiz çeneye 4 adet implant yerleştirilerek analiz gerçekleştirilmiştir. 

Kaynakça

  • Discussion and Conclusion
  • For the loading conditions tested, the maximum stress values did not reach the yield strength of abutment
  • implant/abutment joint systems evaluated. It is seem that the implant is durable all condition dynamic loading and overload at the end of work. Implant can be designed and studied in computer environment before it is implemented on the patient. This will save time for the design and prevent any permanent damage caused by miss-implementation of implant.
  • Many retrospective clinical studies shows high failure
Toplam 4 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Özel Sayı
Yazarlar

Eda Ozyılmaz Bu kişi benim

Halil Aykul Bu kişi benim

Emre Ozyılmaz Bu kişi benim

Mehmet Dalkız Bu kişi benim

M. Bilgin Bu kişi benim

Yayımlanma Tarihi 4 Ocak 2015
Yayımlandığı Sayı Yıl 2014 Cilt: 18 Sayı: 3

Kaynak Göster

APA Ozyılmaz, E., Aykul, H., Ozyılmaz, E., Dalkız, M., vd. (2015). Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 18(3), 175-181.
AMA Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M, Bilgin M. Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants. Süleyman Demirel Üniv. Fen Bilim. Enst. Derg. Ocak 2015;18(3):175-181.
Chicago Ozyılmaz, Eda, Halil Aykul, Emre Ozyılmaz, Mehmet Dalkız, ve M. Bilgin. “Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants”. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 18, sy. 3 (Ocak 2015): 175-81.
EndNote Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M, Bilgin M (01 Ocak 2015) Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 18 3 175–181.
IEEE E. Ozyılmaz, H. Aykul, E. Ozyılmaz, M. Dalkız, ve M. Bilgin, “Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants”, Süleyman Demirel Üniv. Fen Bilim. Enst. Derg., c. 18, sy. 3, ss. 175–181, 2015.
ISNAD Ozyılmaz, Eda vd. “Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants”. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 18/3 (Ocak 2015), 175-181.
JAMA Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M, Bilgin M. Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants. Süleyman Demirel Üniv. Fen Bilim. Enst. Derg. 2015;18:175–181.
MLA Ozyılmaz, Eda vd. “Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants”. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, c. 18, sy. 3, 2015, ss. 175-81.
Vancouver Ozyılmaz E, Aykul H, Ozyılmaz E, Dalkız M, Bilgin M. Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants. Süleyman Demirel Üniv. Fen Bilim. Enst. Derg. 2015;18(3):175-81.

e-ISSN :1308-6529
Linking ISSN (ISSN-L): 1300-7688

Dergide yayımlanan tüm makalelere ücretiz olarak erişilebilinir ve Creative Commons CC BY-NC Atıf-GayriTicari lisansı ile açık erişime sunulur. Tüm yazarlar ve diğer dergi kullanıcıları bu durumu kabul etmiş sayılırlar. CC BY-NC lisansı hakkında detaylı bilgiye erişmek için tıklayınız.