Öz

Minimum energy performance standards increasingly require line-operated induction motors to reach the IE3 efficiency class, and small four-pole motors in centrifugal pump drives are among the machines most affected. For such motors, the margin between the predicted efficiency and the IE3 limit can be only a few tenths of a percentage point, so its design-stage assessment is sensitive to the modelling tool and to the loss assumptions. This study evaluates the IE3 compliance of a 3 kW, 400 V, 50 Hz, four-pole, 36/28-slot squirrel-cage induction motor with a two-slot short-pitched winding. The motor was designed analytically and analysed with the Ansys RMxprt analytical solver and Maxwell 2D transient finite element analysis (FEA). An equivalent circuit identified from the RMxprt losses, a dynamic dq model and a winding-function model were used to interpret the FEA results, and the efficiency was evaluated for different stray-load-loss bases, lamination grades and supply voltages. RMxprt predicts an efficiency of 87.93%, 0.23 percentage points above the IE3 limit of 87.7%; this margin corresponds to only 8.8 W of additional loss. The uncorrected FEA power balance yields 90.3%; when the core and stray-load losses are included and the result is referred to the rated output of 3.00 kW, the FEA efficiency is 87.9–88.2% for two bookkeeping scenarios of a 12.7 W residual loss, in agreement with RMxprt. The IE3 margin is lost when the stray-load loss is taken from the IEC 60034-2-1 assigned allowance (86.74%), when M400-50A lamination is used (87.64%), or when a friction and windage loss of more than about 7 W is included. Short pitching reduces the fifth MMF harmonic from 4.5% to 0.8%, whereas its estimated effect on the efficiency is only about 0.1 percentage points. The FEA-based locked-rotor current is 6.8 times the rated current. These results are design-stage predictions; they show that IE3 assessments of small motors should be based on an explicit loss budget and confirmed by standardised testing.

Anahtar Kelimeler

Kaynakça

  1. ASTM International. (2016). Standard specification for nonoriented electrical steel fully processed types (ASTM A677-16). ASTM International.
  2. Avşar, Y., Fenercioglu, A., & Soyaslan, M. (2024). Design optimization of PM synchronous motor: Rail mounted belt drive elevator systems. IEEE Transactions on Industry Applications, 60(1), 301–311. https://doi.org/10.1109/TIA.2023.3311781
  3. Ballestín-Bernad, V., Artal-Sevil, J. S., & Domínguez-Navarro, J. A. (2023). Prototype of a two-phase axial-gap transverse flux generator based on reused components and 3D printing. Energies, 16(4), 1594. https://doi.org/10.3390/en16041594
  4. Boglietti, A., Cavagnino, A., Ferraris, L., & Lazzari, M. (2010). Impact of the supply voltage on the stray-load losses in induction motors. IEEE Transactions on Industry Applications, 46(4), 1374–1380. https://doi.org/10.1109/TIA.2010.2049721
  5. Boldea, I., & Nasar, S. A. (2010). The induction machines design handbook (2nd ed.). CRC Press. https://doi.org/10.1201/9781315222592
  6. Çelik, E., Garip, M., & Erkan, K. (2024). Optimizing a PMSM with multi-physics approach for fly-gen type airborne wind energy systems. IEEE Access, 12, 66281–66295. https://doi.org/10.1109/ACCESS.2024.3399117
  7. CEN. (2015). Cold rolled non-oriented electrical steel strip and sheet delivered in the fully processed state (EN 10106:2015). European Committee for Standardization.
  8. Contreras, S. F., Cortes, C. A., & Guzmán, M. A. (2017). Modelling of squirrel cage induction motors for a bio-inspired multi-objective optimal design. IET Electric Power Applications, 11(4), 512–523. https://doi.org/10.1049/iet-epa.2016.0672

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Makineleri ve Sürücüler

Bölüm

Araştırma Makalesi

Yazarlar

Berk Demirsoy *
ZONGULDAK BÜLENT ECEVİT ÜNİVERSİTESİ
0009-0003-3489-7346
Türkiye

Mücahit Soyaslan
SAKARYA UYGULAMALI BİLİMLER ÜNİVERSİTESİ
0000-0001-6658-5169
Türkiye

Yayımlanma Tarihi

15 Kasım 2026

Gönderilme Tarihi

18 Ekim 2026

Kabul Tarihi

14 Kasım 2026

Yayımlandığı Sayı

Yıl 2026 Cilt: 9 Sayı: 1

Kaynak Göster

APA
Demirsoy, B., & Soyaslan, M. (2026). Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi, 9(1). https://doi.org/10.51764/smutgd.2065130
AMA
1.Demirsoy B, Soyaslan M. Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models. SMUTGD. 2026;9(1). doi:10.51764/smutgd.2065130
Chicago
Demirsoy, Berk, ve Mücahit Soyaslan. 2026. “Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models”. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi 9 (1). https://doi.org/10.51764/smutgd.2065130.
EndNote
Demirsoy B, Soyaslan M (15 Kasım 2026) Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi 9 1
IEEE
[1]B. Demirsoy ve M. Soyaslan, “Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models”, SMUTGD, c. 9, sy 1, Kas. 2026, doi: 10.51764/smutgd.2065130.
ISNAD
Demirsoy, Berk - Soyaslan, Mücahit. “Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models”. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi 9/1 (15 Kasım 2026). https://doi.org/10.51764/smutgd.2065130.
JAMA
1.Demirsoy B, Soyaslan M. Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models. SMUTGD. 2026;9. doi:10.51764/smutgd.2065130.
MLA
Demirsoy, Berk, ve Mücahit Soyaslan. “Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models”. Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi, c. 9, sy 1, Kasım 2026, doi:10.51764/smutgd.2065130.
Vancouver
1.Berk Demirsoy, Mücahit Soyaslan. Design-Stage Assessment of the IE3 Efficiency Margin of a 3 kW Induction Motor for Pump Applications Using Analytical, Finite Element and Equivalent-Circuit Models. SMUTGD. 15 Kasım 2026;9(1). doi:10.51764/smutgd.2065130