COMPARISION OF INTERNATIONAL CODES FOR STEEL ANCHORS DETAILS USING IN SEISMIC STRENTHENING
Abstract
Having poor seismic performance reinforced concrete frame must be strengthened to reach sufficient seismic performance. The main factor that affects the seismic performance, designing and application of the anchor dowels in the connection zone of infill shear wall and weak reinforced frame. Connection between the frame and the infill wall are usually achieved by using dowels that are placed in the holes drilled into inner faces of the frame members, and fixed by a resin. In this study, the design and detailing guidelines for the design of the post-installed anchors in TEC (2007), ACI 318, JCI (2001) and IS15988 have been compared. According to the results, in ACI 318-14, the shear capacity of anchors is effected by embedment depth, anchor bar diameter, concrete strength, strength of the bar and edge distance. In TEC-2007, shear strength is affected only by two properties of the anchor bar: strength and diameter. JCI-2001 design code considers the two factors outlined in TEC-2007 and concrete strength. Based on the comparison conducted in this study, there are insufficient guidelines in TEC-2007 for the design and detailing of anchor bars that are typically used as connection between an existing frame and new RC infill wall.
Keywords
Kaynakça
- ACI Committee, 2014, Building Code Requirements for Structural Concrete and Commentary (ACI 318-14), American Concrete Institute.
- Altin, S., Ersoy U., Tankut T., 1992,“Hysteretic Response of Reinforced-Concrete Infilled Frames”,ASCE Journal of Structural Engineering, Vol.118(8), pp.2133–2150.
- Altin, S., Anil O., Kara E., 2008, “An Experimental Study on Reinforced Concrete Partially Infilled Frames”, Engineering Structures, Vol. 29,pp.449–460.
- Anil, O., Altin, S., 2007, “An Experimental Study on Reinforced Concrete Partially Infilled Frames”, Engineering Structures, Vol. 29, pp.449-460.
- Çalışkan, Ö.,Yilmaz, S., and Kaplan, H., 2011, “Güçlendirme Ankrajlarının Kesme Dayanımının ACI318 ve TS500’e Göre Belirlenmesi”, Journal of Engineering Sciences, Vol. 14(3), pp. 19-27.
- Çalışkan, Ö., Yılmaz S., Kaplan H., Kıraç N., 2013, “Shear Strength of Epoxy Anchors Embedded Into Low Strength Concrete”, Construction and Building Materials, Vol. 38, pp. 723-730.
- Canbay, E., Ersoy, U.,Ozcebe, G., 2003, “Contribution of Reinforced Concrete Infillsto Seismic Behavior of Structural Systems”, ACI Structural Journal, Vol.100(5), pp. 637-643.
- Canbay, E., 2001, Contribution of RC Infills to The Seismic Behavior of Structural Systems, PhD Dissertation, Middle East Technical University, Ankara.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
1 Eylül 2016
Gönderilme Tarihi
29 Nisan 2016
Kabul Tarihi
21 Haziran 2016
Yayımlandığı Sayı
Yıl 2016 Cilt: 4 Sayı: 3