Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns

Öz

Turkish Seismic Code stipulates capacity design procedure for the calculation of design shear force of RC beams and columns. Therefore, the plastic hinge moment capacity (Mp) at the ends of columns must be determined as accurately as possible. Turkish Seismic Design Code recommends an increase of 40% in ultimate moment capacity (Mr) to obtain the plastic hinge moment capacity (Mp), unless a detailed calculation is carried out. However, this recommendation remains insufficient in attaining plastic hinge moment capacity for high levels of axial load.
In this study, new analytical equations have been derived to obtain the plastic hinge moment capacity of rectangular RC columns in an accurate and practical way. Plastic hinge moment capacity of columns calculated with the proposed equations is compared to the capacity obtained from experimental results. It is shown that the proposed equations yield accurate results

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Cem Aydemir Bu kişi benim

Mustafa Zorbozan Bu kişi benim

Sema Noyan Alacalı Bu kişi benim

Yayımlanma Tarihi

1 Mayıs 2009

Gönderilme Tarihi

18 Haziran 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2009 Cilt: 20 Sayı: 100

Kaynak Göster

APA
Aydemir, C., Zorbozan, M., & Alacalı, S. N. (2009). Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi, 20(100), 1293-1312. https://izlik.org/JA76SJ29NX
AMA
1.Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. 2009;20(100):1293-1312. https://izlik.org/JA76SJ29NX
Chicago
Aydemir, Cem, Mustafa Zorbozan, ve Sema Noyan Alacalı. 2009. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi 20 (100): 1293-1312. https://izlik.org/JA76SJ29NX.
EndNote
Aydemir C, Zorbozan M, Alacalı SN (01 Mayıs 2009) Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi 20 100 1293–1312.
IEEE
[1]C. Aydemir, M. Zorbozan, ve S. N. Alacalı, “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”, Teknik Dergi, c. 20, sy 100, ss. 1293–1312, May. 2009, [çevrimiçi]. Erişim adresi: https://izlik.org/JA76SJ29NX
ISNAD
Aydemir, Cem - Zorbozan, Mustafa - Alacalı, Sema Noyan. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi 20/100 (01 Mayıs 2009): 1293-1312. https://izlik.org/JA76SJ29NX.
JAMA
1.Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. 2009;20:1293–1312.
MLA
Aydemir, Cem, vd. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi, c. 20, sy 100, Mayıs 2009, ss. 1293-12, https://izlik.org/JA76SJ29NX.
Vancouver
1.Cem Aydemir, Mustafa Zorbozan, Sema Noyan Alacalı. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi [Internet]. 01 Mayıs 2009;20(100):1293-312. Erişim adresi: https://izlik.org/JA76SJ29NX