Öz

Turkish Seismic Code stipulates capacity design procedure for the calculation of design shear force of RC beams and columns. Therefore, the plastic hinge moment capacity (Mp) at the ends of columns must be determined as accurately as possible. Turkish Seismic Design Code recommends an increase of 40% in ultimate moment capacity (Mr) to obtain the plastic hinge moment capacity (Mp), unless a detailed calculation is carried out. However, this recommendation remains insufficient in attaining plastic hinge moment capacity for high levels of axial load.
In this study, new analytical equations have been derived to obtain the plastic hinge moment capacity of rectangular RC columns in an accurate and practical way. Plastic hinge moment capacity of columns calculated with the proposed equations is compared to the capacity obtained from experimental results. It is shown that the proposed equations yield accurate results

Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns

Yıl 2009, Cilt: 20 Sayı: 100, 1293 - 1312, 01.05.2009

Öz

-

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Makale
Yazarlar

Cem Aydemir Bu kişi benim

Mustafa Zorbozan Bu kişi benim

Sema Noyan Alacalı Bu kişi benim

Yayımlanma Tarihi 1 Mayıs 2009
Gönderilme Tarihi 18 Haziran 2015
Yayımlandığı Sayı Yıl 2009 Cilt: 20 Sayı: 100

Kaynak Göster

APA Aydemir, C., Zorbozan, M., & Alacalı, S. N. (2009). Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi, 20(100), 1293-1312.
AMA Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. Mayıs 2009;20(100):1293-1312.
Chicago Aydemir, Cem, Mustafa Zorbozan, ve Sema Noyan Alacalı. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi 20, sy. 100 (Mayıs 2009): 1293-1312.
EndNote Aydemir C, Zorbozan M, Alacalı SN (01 Mayıs 2009) Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi 20 100 1293–1312.
IEEE C. Aydemir, M. Zorbozan, ve S. N. Alacalı, “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”, Teknik Dergi, c. 20, sy. 100, ss. 1293–1312, 2009.
ISNAD Aydemir, Cem vd. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi 20/100 (Mayıs 2009), 1293-1312.
JAMA Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. 2009;20:1293–1312.
MLA Aydemir, Cem vd. “Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns”. Teknik Dergi, c. 20, sy. 100, 2009, ss. 1293-12.
Vancouver Aydemir C, Zorbozan M, Alacalı SN. Determination of Moment Capacity Mp for Rectangular Reinforced Concrete Columns. Teknik Dergi. 2009;20(100):1293-312.